35 changes: 35 additions & 0 deletions packages/modules/devices/keba/keba_e10/config.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,35 @@
from typing import Optional

from modules.common.component_setup import ComponentSetup
from ..vendor import vendor_descriptor


class KebaE10Configuration:
def __init__(self, ip_address: Optional[str] = None, port: int = 502, modbus_id: int = 1):
self.ip_address = ip_address
self.port = port
self.modbus_id = modbus_id


class KebaE10:
def __init__(self, name: str = "KEBA KeContact E10", type: str = "keba_e10",
id: int = 0, configuration: KebaE10Configuration = None) -> None:
self.name = name
self.type = type
self.vendor = vendor_descriptor.configuration_factory().type
self.id = id
self.configuration = configuration or KebaE10Configuration()


class KebaE10CounterConfiguration:
def __init__(self) -> None:
pass


class KebaE10CounterSetup(ComponentSetup[KebaE10CounterConfiguration]):
def __init__(self, name: str = "KEBA KeContact E10 EVU-Zähler", type: str = "counter",
id: int = 0, configuration: KebaE10CounterConfiguration = None) -> None:
super().__init__(name, type, id, configuration or KebaE10CounterConfiguration())

self.info["manufacturer"] = "KEBA"
self.info["model"] = "Keba KeContact E10 Smart Energy Meter"
98 changes: 98 additions & 0 deletions packages/modules/devices/keba/keba_e10/counter.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,98 @@
#!/usr/bin/env python3
from typing import Any, TypedDict

from modules.common import modbus
from modules.common.abstract_device import AbstractCounter
from modules.common.component_state import CounterState
from modules.common.component_type import ComponentDescriptor, ComponentType
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.modbus import ModbusDataType
from modules.devices.keba.keba_e10.config import KebaE10CounterSetup


class KwargsDict(TypedDict):
client: modbus.ModbusTcpClient_
modbus_id: int


class KebaE10Counter(AbstractCounter):
def __init__(self, component_config: KebaE10CounterSetup, **kwargs: Any) -> None:
self.component_config = component_config
self.kwargs: KwargsDict = kwargs

def initialize(self) -> None:
self.__tcp_client: modbus.ModbusTcpClient_ = self.kwargs["client"]
self.__modbus_id: int = self.kwargs["modbus_id"]
from modules.common.store._counter import get_counter_value_store
from modules.common.utils.peak_filter import PeakFilter
self.store = get_counter_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))
self.peak_filter = PeakFilter(ComponentType.COUNTER, self.component_config.id, self.fault_state)

def __u32(self, address: int) -> int:
return int(self.__tcp_client.read_holding_registers(
address, ModbusDataType.UINT_32, unit=self.__modbus_id
))

def __i32(self, address: int) -> int:
return int(self.__tcp_client.read_holding_registers(
address, ModbusDataType.INT_32, unit=self.__modbus_id
))

def update(self) -> None:
# The E10 exposes these values as high-word-first 32-bit Holding Registers.
# openWB's Modbus wrapper decodes UINT_32 using big-endian word order.
with self.__tcp_client:
active_plus = self.__u32(0)
active_minus = self.__u32(2)

# Lifetime counters are uint64. Raw/10 yields Wh (raw/10000 yields kWh).
imported, exported = [
value / 10.0 for value in self.__tcp_client.read_holding_registers(
512, [ModbusDataType.UINT_64, ModbusDataType.UINT_64],
unit=self.__modbus_id
)
]

frequency = self.__u32(26) / 1000.0

powers = [
(self.__u32(40) - self.__u32(42)) / 10.0,
(self.__u32(80) - self.__u32(82)) / 10.0,
(self.__u32(120) - self.__u32(122)) / 10.0,
]
currents = [
self.__u32(60) / 1000.0,
self.__u32(100) / 1000.0,
self.__u32(140) / 1000.0,
]
voltages = [
self.__u32(62) / 1000.0,
self.__u32(102) / 1000.0,
self.__u32(142) / 1000.0,
]
power_factors = [
self.__i32(64) / 1000.0,
self.__i32(104) / 1000.0,
self.__i32(144) / 1000.0,
]

# Keep import positive and export negative at the EVU point.
# The E10 gives separate positive/negative registers; subtracting them
# produces the signed net power used by openWB.
power = (active_plus - active_minus) / 10.0
imported, exported = self.peak_filter.check_values(power, imported, exported)

self.store.set(CounterState(
imported=imported,
exported=exported,
power=power,
powers=powers,
currents=currents,
voltages=voltages,
power_factors=power_factors,
frequency=frequency
))


component_descriptor = ComponentDescriptor(configuration_factory=KebaE10CounterSetup)
35 changes: 35 additions & 0 deletions packages/modules/devices/keba/keba_e10/device.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,35 @@
from modules.common import modbus
from modules.common.abstract_device import DeviceDescriptor
from modules.common.configurable_device import (
ConfigurableDevice, ComponentFactoryByType, IndependentComponentUpdater
)
from modules.devices.keba.keba_e10.config import KebaE10, KebaE10CounterSetup
from modules.devices.keba.keba_e10.counter import KebaE10Counter


def create_device(device_config: KebaE10):
client = None

def create_counter_component(component_config: KebaE10CounterSetup):
return KebaE10Counter(
component_config,
client=client,
modbus_id=device_config.configuration.modbus_id
)

def initializer():
nonlocal client
client = modbus.ModbusTcpClient_(
device_config.configuration.ip_address,
device_config.configuration.port
)

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
component_factory=ComponentFactoryByType(counter=create_counter_component),
component_updater=IndependentComponentUpdater(lambda component: component.update()),
)


device_descriptor = DeviceDescriptor(configuration_factory=KebaE10)
14 changes: 14 additions & 0 deletions packages/modules/devices/keba/vendor.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,14 @@
from pathlib import Path

from modules.common.abstract_device import DeviceDescriptor
from modules.devices.vendors import VendorGroup


class Vendor:
def __init__(self):
self.type = Path(__file__).parent.name
self.vendor = "KEBA"
self.group = VendorGroup.VENDORS.value


vendor_descriptor = DeviceDescriptor(configuration_factory=Vendor)