8 changes: 6 additions & 2 deletions packages/modules/devices/fronius/fronius_http_api/counter.py
Original file line number Diff line number Diff line change
Expand Up @@ -70,8 +70,12 @@ def update(self, powerflow_response: Dict, meter_system_response: Optional[Dict]
if meter.location in (MeterLocation.external, MeterLocation.subload):
power *= -1

currents = [powers[i] / meter.voltages[i] for i in range(0, 3)]

currents = [
powers[i] / meter.voltages[i]
if powers[i] is not None and meter.voltages[i] not in (None, 0)
else 0
for i in range(3)
]
counter_state = CounterState(
voltages=meter.voltages,
currents=currents,
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -50,7 +50,12 @@ def update(self, meter_system_response: Optional[Dict] = None) -> None:
# Dokumentation (4.8.6/4.8.7) positive Werte für Erzeugung -- openWBs Konvention ist umgekehrt
# (negativ = Erzeugung, siehe inverter.py), daher wird hier immer invertiert.
power = meter.power_sum * -1
currents = [meter.powers[i] / meter.voltages[i] for i in range(0, 3)]
currents = [
meter.powers[i] / meter.voltages[i]
if meter.powers[i] is not None and meter.voltages[i] not in (None, 0)
else 0
for i in range(3)
]

self.peak_filter.check_values(power)
_, exported = self.sim_counter.sim_count(power)
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -36,20 +36,20 @@ def read_meter(session: Session,
data = _fetch_device_scope(session, ip_address, meter_id, variant)
location_key = "Meter_Location_Current"
power_sum_key = "PowerReal_P_Sum"
powers = [data["PowerReal_P_Phase_"+str(num)] for num in range(1, 4)]
voltages = [data["Voltage_AC_Phase_"+str(num)] for num in range(1, 4)]
power_factors = [data["PowerFactor_Phase_"+str(num)] for num in range(1, 4)]
frequency = data["Frequency_Phase_Average"]
powers = [data.get(f"PowerReal_P_Phase_{num}", 0) for num in range(1, 4)]
voltages = [data.get(f"Voltage_AC_Phase_{num}", 0) for num in range(1, 4)]
power_factors = [data.get(f"PowerFactor_Phase_{num}", 0) for num in range(1, 4)]
frequency = data.get("Frequency_Phase_Average", 50)
elif variant == 2:
if meter_system_response is None:
raise ValueError("meter_system_response wird für Variante 2 benötigt")
data = dict(meter_system_response["Body"]["Data"]).get(str(meter_id))
location_key = "SMARTMETER_VALUE_LOCATION_U16"
power_sum_key = "SMARTMETER_POWERACTIVE_MEAN_SUM_F64"
powers = [data["SMARTMETER_POWERACTIVE_MEAN_0"+str(num)+"_F64"] for num in range(1, 4)]
voltages = [data["SMARTMETER_VOLTAGE_0"+str(num)+"_F64"] for num in range(1, 4)]
power_factors = [data["SMARTMETER_FACTOR_POWER_0"+str(num)+"_F64"] for num in range(1, 4)]
frequency = data["GRID_FREQUENCY_MEAN_F32"]
powers = [data.get(f"SMARTMETER_POWERACTIVE_MEAN_0{num}_F64", 0) for num in range(1, 4)]
voltages = [data.get(f"SMARTMETER_VOLTAGE_0{num}_F64", 0) for num in range(1, 4)]
power_factors = [data.get(f"SMARTMETER_FACTOR_POWER_0{num}_F64", 0) for num in range(1, 4)]
frequency = data.get("GRID_FREQUENCY_MEAN_F32", 50)
else:
raise ValueError("Unbekannte Variante: "+str(variant))

Expand Down