7 changes: 4 additions & 3 deletions docs/samples/sample_modbus/sample_modbus/bat.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
#!/usr/bin/env python3
from enum import IntEnum
from typing import Optional, TypedDict, Any
from typing import TypedDict, Any
from modules.common.abstract_device import AbstractBat
from modules.common.component_state import BatState
from modules.common.component_type import ComponentDescriptor
Expand All @@ -11,6 +11,7 @@
from modules.devices.sample_modbus.sample_modbus.config import SampleBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint


class KwargsDict(TypedDict):
Expand Down Expand Up @@ -79,11 +80,11 @@ def update(self) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
Comment thread
ndrsnhs marked this conversation as resolved.
Resolved
# Wenn der Speicher die Steuerung der Ladeleistung unterstützt, muss bei Übergabe einer Zahl auf aktive
# Speichersteurung umgeschaltet werden, sodass der Speicher mit der übergebenen Leistung lädt/entlädt. Wird
# None übergeben, muss der Speicher die Null-Punkt-Ausregelung selbst übernehmen.
self.client.write_register(reg, power_limit)
self.client.write_register(reg, setpoint.power_limit)
# Wenn der Speicher keine Steuerung der Ladeleistung unterstützt
pass

Expand Down
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
#!/usr/bin/env python3
from typing import Optional, TypedDict, Any
from typing import TypedDict, Any
from modules.common import req
from modules.common.abstract_device import AbstractBat
from modules.common.component_state import BatState
Expand All @@ -10,6 +10,7 @@
from modules.devices.sample_request_by_component.sample_request_by_component.config import SampleBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint


class KwargsDict(TypedDict):
Expand Down Expand Up @@ -45,11 +46,11 @@ def update(self) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
# Wenn der Speicher die Steuerung der Ladeleistung unterstützt, muss bei Übergabe einer Zahl auf aktive
# Speichersteurung umgeschaltet werden, sodass der Speicher mit der übergebenen Leistung lädt/entlädt. Wird
# None übergeben, muss der Speicher die Null-Punkt-Ausregelung selbst übernehmen.
self.client.write_register(reg, power_limit)
self.client.write_register(reg, setpoint.power_limit)
# Wenn der Speicher keine Steuerung der Ladeleistung unterstützt
pass

Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -9,6 +9,7 @@
from modules.devices.sample_request_by_device.sample_request_by_device.config import SampleBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint


class KwargsDict(TypedDict):
Expand Down Expand Up @@ -42,11 +43,11 @@ def update(self, response) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
Comment thread
ndrsnhs marked this conversation as resolved.
Resolved
# Wenn der Speicher die Steuerung der Ladeleistung unterstützt, muss bei Übergabe einer Zahl auf aktive
# Speichersteurung umgeschaltet werden, sodass der Speicher mit der übergebenen Leistung lädt/entlädt. Wird
# None übergeben, muss der Speicher die Null-Punkt-Ausregelung selbst übernehmen.
self.client.write_register(reg, power_limit)
self.client.write_register(reg, setpoint.power_limit)
# Wenn der Speicher keine Steuerung der Ladeleistung unterstützt
pass

Expand Down
1 change: 1 addition & 0 deletions packages/control/bat.py
Original file line number Diff line number Diff line change
Expand Up @@ -42,6 +42,7 @@ def get_factory() -> Get:
@dataclass
class Set:
power_limit: Optional[int] = field(default=None, metadata={"topic": "set/power_limit"})
evu_power: Optional[int] = field(default=None, metadata={"topic": "set/evu_power"})


def set_factory() -> Set:
Expand Down
3 changes: 2 additions & 1 deletion packages/control/bat_all.py
Original file line number Diff line number Diff line change
Expand Up @@ -295,7 +295,8 @@ def _set_bat_power_active_control(self, power):
log.debug(("Aktive Speichersteuerung: Ladung - "
f"Speicher (ID: {bat_component.component_config.id}) "
f"laden mit {power_limit} ({factor} x {bat_component_data.get.max_charge_power}) W"))
data.data.bat_data[f"bat{bat_component.component_config.id}"].data.set.power_limit = power_limit
bat_component_data.set.power_limit = power_limit
bat_component_data.set.evu_power = data.data.counter_all_data.get_evu_counter().data.get.power

def setup_bat(self):
""" prüft, ob mind ein Speicher vorhanden ist und berechnet die Summen-Topics.
Expand Down
6 changes: 5 additions & 1 deletion packages/control/process.py
Original file line number Diff line number Diff line change
Expand Up @@ -24,6 +24,7 @@
from modules.io_actions.controllable_consumers.dimming_direct_control.api import DimmingDirectControl
from modules.io_actions.generator_systems.stepwise_control.api_eebus import StepwiseControlEebus
from modules.io_actions.generator_systems.stepwise_control.api_io import StepwiseControlIo
from dataclasses import replace

log = logging.getLogger(__name__)
control_command_log = logging.getLogger("steuve_control_command")
Expand Down Expand Up @@ -71,11 +72,14 @@ def process_algorithm_results(self) -> None:
log.exception("Fehler im Process-Modul für Ladepunkt "+str(cp))
if data.data.bat_all_data.data.set.set_limit:
for bat_component in get_bat_components_by_controllability()[0]:
setpoint = replace(
data.data.bat_data[f"bat{bat_component.component_config.id}"].data.set
)
modules_threads.append(
Thread(
target=set_power_limit_wrapper,
args=(bat_component,
data.data.bat_data[f"bat{bat_component.component_config.id}"].data.set.power_limit),
setpoint),
name=f"set power limit {bat_component.component_config.id}"))
for consumer in data.data.consumer_data.values():
try:
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -20,6 +20,7 @@ def _get_data_path() -> Path:
INTERNAL_TOPICS = ['openWB/bat/set/charging_power_left',
'openWB/bat/set/regulate_up',
'openWB/bat/+/set/power_limit',
'openWB/bat/+/set/evu_power',
'openWB/command/max_id/autolock_plan',
'openWB/command/max_id/charge_template',
'openWB/command/max_id/charge_template_scheduled_plan',
Expand Down
2 changes: 2 additions & 0 deletions packages/helpermodules/setdata.py
Original file line number Diff line number Diff line change
Expand Up @@ -743,6 +743,8 @@ def process_bat_topic(self, msg: mqtt.MQTTMessage):
self._validate_value(msg, bool)
elif "/set/power_limit" in msg.topic:
self._validate_value(msg, float)
elif "/set/evu_power" in msg.topic:
self._validate_value(msg, float)
else:
self.__unknown_topic(msg)
else:
Expand Down
1 change: 1 addition & 0 deletions packages/helpermodules/update_config.py
Original file line number Diff line number Diff line change
Expand Up @@ -105,6 +105,7 @@ class UpdateConfig:
"^openWB/bat/[0-9]+/get/fault_str$",
"^openWB/bat/[0-9]+/get/power_limit_controllable$",
"^openWB/bat/[0-9]+/set/power_limit$",
"^openWB/bat/[0-9]+/set/evu_power$",

"^openWB/chargepoint/get/power$",
"^openWB/chargepoint/get/exported$",
Expand Down
10 changes: 8 additions & 2 deletions packages/modules/common/abstract_device.py
Original file line number Diff line number Diff line change
@@ -1,5 +1,11 @@
from __future__ import annotations
from abc import abstractmethod
from typing import Optional, Type
from typing import Optional, Type, Protocol


class SetPoint(Protocol):
power_limit: Optional[int]
evu_power: Optional[int]


class AbstractDevice:
Expand Down Expand Up @@ -31,7 +37,7 @@ def update(self, *kwargs) -> None:
pass

@abstractmethod
def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
Comment thread
ndrsnhs marked this conversation as resolved.
Resolved
# power limit None heißt, auf maximale Speicherleistung setzen = Speicher-Begrenzung aufheben
pass

Expand Down
7 changes: 4 additions & 3 deletions packages/modules/common/configurable_device.py
Original file line number Diff line number Diff line change
@@ -1,13 +1,14 @@
import inspect
import logging
from typing import Optional, TypeVar, Generic, Dict, Any, Callable, Iterable, List
from typing import TypeVar, Generic, Dict, Any, Callable, Iterable, List

from dataclass_utils import dataclass_from_dict
from helpermodules import timecheck
from helpermodules.pub import Pub
from modules.common.abstract_device import AbstractBat, AbstractDevice
from modules.common.component_context import SingleComponentUpdateContext, MultiComponentUpdateContext
from modules.common.fault_state import ComponentInfo, FaultState
from control.bat import Set as SetPoint

T_DEVICE_CONFIG = TypeVar("T_DEVICE_CONFIG")
T_COMPONENT = TypeVar("T_COMPONENT")
Expand Down Expand Up @@ -130,9 +131,9 @@ def update(self):
self.__component_updater(initialized_components, self.error_handler)


def set_power_limit_wrapper(bat_component: AbstractBat, power_limit: Optional[int]):
def set_power_limit_wrapper(bat_component: AbstractBat, setpoint: SetPoint):
"""set_power_limit innerhalb des SingleComponentUpdateContext aufrufen,
damit Fehler im fault_state-Handler behandelt werden
"""
with SingleComponentUpdateContext(bat_component.fault_state, update_always=False):
bat_component.set_power_limit(power_limit)
bat_component.set_power_limit(setpoint)
9 changes: 5 additions & 4 deletions packages/modules/devices/alpha_ess/alpha_ess/bat.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
import logging
import time
from typing import TypedDict, Any, Optional
from typing import TypedDict, Any
from modules.common.abstract_device import AbstractBat
from modules.common.component_state import BatState
from modules.common.component_type import ComponentDescriptor
Expand All @@ -11,6 +11,7 @@
from modules.devices.alpha_ess.alpha_ess.config import AlphaEssBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint

log = logging.getLogger(__name__)

Expand Down Expand Up @@ -62,16 +63,16 @@ def update(self) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
unit = self.__modbus_id

if power_limit is None:
if setpoint.power_limit is None:
# Kein Powerlimit gefordert, externe Steuerung deaktivieren
log.debug("Keine Batteriesteuerung gefordert, deaktiviere externe Steuerung.")
if self.last_mode is not None:
self.__tcp_client.write_register(2127, 0, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = None
elif power_limit <= 0:
elif setpoint.power_limit <= 0:
# AlphaESS kann die Entladung nur über den SoC verhindern (komplette Entladesperre)
# Netzladung mit geringen Ziel SoC verhindert auch Entladung (Default 10%)
# Zeiten für Netzladung müssen im Wechselrichter aktiviert werden
Expand Down
11 changes: 6 additions & 5 deletions packages/modules/devices/anker/solarbank/bat.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
#!/usr/bin/env python3
import logging
from typing import Any, Optional, TypedDict
from typing import Any, TypedDict

from modules.common.abstract_device import AbstractBat
from modules.common.component_state import BatState
Expand All @@ -12,6 +12,7 @@
from modules.devices.anker.solarbank.config import Anker, AnkerBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint

log = logging.getLogger(__name__)

Expand Down Expand Up @@ -52,10 +53,10 @@ def update(self) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
unit = self.device_config.configuration.modbus_id

if power_limit is None:
if setpoint.power_limit is None:
log.debug("Keine Batteriesteuerung, Selbstregelung durch Wechselrichter")
if self.last_mode is not None:
self.client.write_register(10064, 0, data_type=ModbusDataType.UINT_16, unit=unit)
Expand All @@ -65,9 +66,9 @@ def set_power_limit(self, power_limit: Optional[int]) -> None:
self.client.write_register(10064, 3, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = 'limited'

power_value = 0 if power_limit == 0 else int(power_limit) * -1
power_value = 0 if setpoint.power_limit == 0 else int(setpoint.power_limit) * -1
self.client.write_register(10071, power_value, data_type=ModbusDataType.INT_32, unit=unit)
log.debug("Aktive Batteriesteuerung angefordert, angeforderte Leistung: {power_value} W")
log.debug(f"Aktive Batteriesteuerung angefordert, angeforderte Leistung: {power_value} W")

def power_limit_controllable(self) -> bool:
return True
Expand Down
9 changes: 5 additions & 4 deletions packages/modules/devices/batterx/batterx/bat.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
#!/usr/bin/env python3
import logging
from typing import Dict, TypedDict, Any, Optional
from typing import Dict, TypedDict, Any

from modules.devices.batterx.batterx.config import BatterXBatSetup
from modules.common.abstract_device import AbstractBat
Expand All @@ -12,6 +12,7 @@
from modules.common import req
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint

log = logging.getLogger(__name__)

Expand Down Expand Up @@ -49,10 +50,10 @@ def update(self, resp: Dict) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
log.debug(f'last_mode: {self.last_mode}')

if power_limit is None:
if setpoint.power_limit is None:
# Kein Powerlimit gefordert, externe Steuerung deaktivieren
log.debug("Keine Batteriesteuerung gefordert, deaktiviere externe Steuerung.")
if self.last_mode is not None:
Expand All @@ -67,7 +68,7 @@ def set_power_limit(self, power_limit: Optional[int]) -> None:
timeout=5
)
self.last_mode = None
elif power_limit <= 0:
elif setpoint.power_limit <= 0:
# BatterX kann Entladung nur komplett sperren
log.debug("Aktive Batteriesteuerung angestoßen. Setze Entladesperre.")
if self.last_mode != 'stop':
Expand Down
21 changes: 11 additions & 10 deletions packages/modules/devices/fox_ess/fox_ess_h3_smart/bat.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
#!/usr/bin/env python3
import logging
from typing import TypedDict, Any, Optional
from typing import TypedDict, Any

from modules.common.abstract_device import AbstractBat
from modules.common.component_state import BatState
Expand All @@ -12,6 +12,7 @@
from modules.devices.fox_ess.fox_ess_h3_smart.config import FoxEssH3SmartBatSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType
from control.bat import Set as SetPoint

log = logging.getLogger(__name__)

Expand Down Expand Up @@ -50,17 +51,17 @@ def update(self) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
def set_power_limit(self, setpoint: SetPoint) -> None:
unit = self.component_config.configuration.modbus_id

if power_limit is None:
if setpoint.power_limit is None:
log.debug("Keine Batteriesteuerung, Selbstregelung durch Wechselrichter")
if self.last_mode is not None:
# remote control disabled, mode self use (1)
self.__tcp_client.write_register(46001, 0, data_type=ModbusDataType.UINT_16, unit=unit)
self.__tcp_client.write_register(49203, 1, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = None
elif power_limit == 0:
elif setpoint.power_limit == 0:
# remote control enabled, watchdog 60s, active power 0W, mode FeedIn Priority (2)
log.debug("Aktive Batteriesteuerung. FoxEss H3 Smart wird auf Stop gesetzt und nicht entladen")
if self.last_mode != 'stop':
Expand All @@ -69,26 +70,26 @@ def set_power_limit(self, power_limit: Optional[int]) -> None:
self.__tcp_client.write_register(49203, 2, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = 'stop'
self.__tcp_client.write_register(46003, 0, data_type=ModbusDataType.UINT_16, unit=unit)
elif power_limit < 0:
elif setpoint.power_limit < 0:
# remote control enabled, watchdog 60s, active power 0W, mode Backup (3)
log.debug(f"Aktive Batteriesteuerung FoxEss H3 Smart:"
f"Speicher soll mit {power_limit} W entladen werden")
f"Speicher soll mit {setpoint.power_limit} W entladen werden")
if self.last_mode != 'discharge':
self.__tcp_client.write_register(46001, 1, data_type=ModbusDataType.UINT_16, unit=unit)
self.__tcp_client.write_register(46002, 60, data_type=ModbusDataType.UINT_16, unit=unit)
self.__tcp_client.write_register(49203, 3, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = 'discharge'
self.__tcp_client.write_register(46003, -power_limit, data_type=ModbusDataType.UINT_16, unit=unit)
elif power_limit > 0:
self.__tcp_client.write_register(46003, -setpoint.power_limit, data_type=ModbusDataType.UINT_16, unit=unit)
elif setpoint.power_limit > 0:
# remote control enabled, watchdog 60s, active power 0W, mode Backup (3)
log.debug(f"Aktive Batteriesteuerung FoxEss H3 Smart:"
f"Speicher soll mit {power_limit} W geladen werden")
f"Speicher soll mit {setpoint.power_limit} W geladen werden")
if self.last_mode != 'charge':
self.__tcp_client.write_register(46001, 1, data_type=ModbusDataType.UINT_16, unit=unit)
self.__tcp_client.write_register(46002, 60, data_type=ModbusDataType.UINT_16, unit=unit)
self.__tcp_client.write_register(49203, 3, data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = 'charge'
self.__tcp_client.write_register(46003, -power_limit, data_type=ModbusDataType.UINT_16, unit=unit)
self.__tcp_client.write_register(46003, -setpoint.power_limit, data_type=ModbusDataType.UINT_16, unit=unit)

def power_limit_controllable(self) -> bool:
return True
Expand Down