Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
The rc6 default x64 ZIP and NSIS installer use the Win7-compatible runtime, whose packaging path omitted usbmmidd_v2. The reporter’s #52 logs show an empty display list followed by repeated
Driver inf file not founderrors when RDP disconnects. Stage the pinned optional Windows 10+ IDD resources into that runtime and require the full bundle before creating an installer.The driver remains behind the existing Windows build 19041 runtime gate. Its exact DLL is validated by checksum separately from Win7 application PE compatibility checks; ordinary application DLLs and unexpected DLLs retain the existing checks. Record the optional driver in build provenance.
Validation: 30 packaging/build tests passed, including real NSIS compilation, missing/corrupt bundle rejection, preservation of user profiles, and rejection of unexpected incompatible DLLs. Staged the real pinned upstream archive, repackaged the released rc6 runtime and compiled a corrected installer. All 16 original application binaries retain their SHA-256 hashes, and the resulting ZIP passes integrity checks. Actual Windows installation and headless/RDP behavior still require device testing. This addresses the confirmed missing-driver blocker in #52; further session-recovery issues may remain.