Notifications
You must be signed in to change notification settings - Fork 8
chore(drivers): move the bundled pin to device-drivers@76c968bd #722
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Merged
Merged
Changes from all commits
Commits
File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,9 @@ | ||
| --- | ||
| "ftw": patch | ||
| --- | ||
|
|
||
| Move the bundled-driver pin to device-drivers@76c968bd. A gateway booting | ||
| offline no longer retries the Sungrow EMS control block on an inverter that | ||
| has already refused it — an SG string inverter logged a failed | ||
| self-consumption reset once per watchdog tick for the life of the session. | ||
| Sungrow is the only bundled driver the move changes (1.5.6 → 1.5.7). |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
When a controllable hybrid is left in forced EMS mode and three default-mode attempts encounter a temporary TCP outage or reconnect backoff, the pinned 1.5.7 driver counts those errors as refusals and suppresses subsequent reset writes for the rest of the session.
host.modbus_writereturns transport errors as well as definitive Modbus exceptions, so if connectivity recovers while dispatch remains stopped—for example, because the site meter is still stale—the watchdog cannot return the inverter to autonomous mode until FTW restarts. Only latch the unsupported-block state for a definitive device rejection, or resume attempts after transport recovery.AGENTS.md reference: AGENTS.md:L31-L32
Useful? React with 👍 / 👎.