Repository navigation
Add S-Bio MS-9384U 384-well plate labware - #41
Draft
kingbedjed wants to merge 5 commits into
Draft
kingbedjed wants to merge 5 commits into
kingbedjed wants to merge 5 commits into
Conversation
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This branch has not been deployed
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
The request
Slack
#labware-requests, requester Slack userU0APRMP9RH8, 2026-10-30 (permalink):Closes #40
Decisions needed
notes. Is that right, and which code is on the requester's box?top_shape: square,diameter_top3.3 mm (side),shape: circle,diameter2.92 mm. A look at a plate in hand would settle it.What is included
S-Bio_MS-9384U_384_well_plate.jsonFigures
S-BIO PrimeSurface dimensions to support instrument setup, page 1, cropped to the table (last row is MS-9384UZ)
S-Bio PrimeSurface product photo from the product page; the two 384-well plates are on the right (white 384W top, clear 384U bottom)
Sources used
Judgement calls
diameter= 2.92 mm is the table's "bottom" value anddiameter_top= 3.3 mm its "top" value. The opening is taken as square (see Decisions needed).floor_height2.4 mm,bottom_elevation1.6 mm,bottom_thickness0.8 mm.working_volume_maxis the table's 100 µL well volume; the brochure's 106 µL maximum is innotes.skirt_height2.5 mm is the table's "Flange or Skirt Height". There is no drawing, so the skirt outline and flange width are not recorded and nothing was scaled.Testing
pytest -q: 184 passed.lint(ruff 0.15.22 check + format --check, ty 0.0.74 via pixi, as inlint.yml): all checks passed.🤖 Generated with Claude Code
Opened by the
add-labwareskill of ramona-claude 0.16.0 (ramona-llm c377eb0, prompt bc769991).