This is the official Container Storage Interface (CSI) driver for QNAP NAS devices.
- Introduction
- Software Prerequisites
- Supported Features
- Installation
- CSI Driver Configuration
- Deployment
- Operations
- Troubleshooting
The QNAP CSI driver is a storage service designed to provide volumes from local or remote NAS devices to Kubernetes. It is based on NetApp Trident, providing dynamic volume provisioning. The driver supports quality of service (QoS) assignment to ensure optimal performance tailored to application needs.
The key concepts in this driver are backend and pools. A backend represents the NAS storage used for PersistentVolumeClaim (PVC) requests. Each backend contains virtual pools, which are logical groupings of storage that dynamically select an appropriate physical pool based on specific requirements. PVCs request storage through a StorageClass, which binds to the virtual pool, ensuring the volume is created from the correct physical resources. The process for creating a volume using this driver is as follows (also illustrated in Figure 1):
- The user claims a PVC request specifying a StorageClass.
- The system binds the request to a suitable virtual pool configured in the backend.
- The system filters the available physical pools based on the required features.
- A suitable physical pool is selected from the filtered options.
- The requested volume is created on the selected physical pool.
Tip
The system prioritizes selecting the backend with the lowest current volume usage to ensure load balancing.

| Driver Version | Supported Kubernetes Versions | Supported QNAP NAS Operating Systems |
|---|---|---|
| v1.6.3 | v1.24 to v1.35 | QTS 5.1.0 or later (including QTS 6.0) QuTS hero h5.1.0 or later (including QuTS hero h6.0.0) |
- Debian 8 or later
- Ubuntu 16.04 or later
- CentOS 7.0 or later
- RHEL 7.0 or later
- CoreOS 1353.8.0 or later
- Talos 1.8 or later
- AMD64
- ARM64 and ARMv7
- Protocol: iSCSI, SMB
- High Availability: iSCSI Multipath support
- Security: iSCSI CHAP Authentication
- Access mode: ReadWriteOnce, ReadWriteMany
- Data Services: Snapshots, Cloning, Expansion
- Pool level: RAID levels, SSD cache, Tiering
- Optimization: Thin Provisioning, Deduplication, Compression, Thresholds
Note
QuTS hero high availability clusters: Synchronization between the active and passive nodes is managed by the high availability service on the NAS. A PVC operation completes once the active node has processed the request, and the NAS then synchronizes the volume to the passive node. To confirm that new, cloned, or restored volumes are protected, check the high availability cluster status in the High Availability Manager QPKG.
- Ensure that both the Kubernetes and the QNAP NAS operating system versions are supported.
Note
- Minikube is not supported.
- On Rancher-managed clusters, the driver auto-detects the Rancher environment and completes all Rancher-specific tasks automatically.
-
If you plan to use the iSCSI protocol, you must install the required iSCSI utilities on all Kubernetes master and worker nodes. You can choose to use a single-path iSCSI setup for basic connectivity, or a multipath iSCSI setup if you require path redundancy, load balancing, or improved performance.
-
Single-Path iSCSI Setup
sudo apt install open-iscsi[!NOTE] Use this setup when the backend declares at most one interface in
networkInterfaces.The driver decides whether an iSCSI volume needs a multipath device by checking whether the
multipathcommand is available on the node. If it is, every iSCSI volume must have a multipath device before it can be mounted. At its default setting,multipathddoes not create a multipath device for a LUN with only one path, so the volume may fail to mount.Several Linux distributions install multipath tooling as part of a default or recommended package set, so check each worker node even if you never configured multipath:
command -v multipathIf the command prints a path, we recommend one of the following:
- Remove the multipath tooling (recommended for single-path nodes):
sudo apt remove multipath-tools # Debian / Ubuntu sudo yum remove device-mapper-multipath # CentOS / RHEL- Or keep it and set
find_multipaths noin/etc/multipath.conf, then restartmultipathd, as described in the Multipath iSCSI Setup below. Note that this setting applies to the whole host.
Stopping or disabling the
multipathdservice alone is not enough, because themultipathcommand remains available after the service is stopped. -
Multipath iSCSI Setup Install the required packages
sudo apt-get install -y open-iscsi lsscsi sg3-utils multipath-tools scsitoolsSet scanning to manual
sudo sed -i 's/^\(node.session.scan\).*/\1 = manual/' /etc/iscsi/iscsid.confCreate or edit the multipath configuration file
sudo tee /etc/multipath.conf <<-EOF defaults { user_friendly_names yes find_multipaths no } devices { device { vendor "QNAP" product "iSCSI Storage" fast_io_fail_tmo 120 no_path_retry queue } } EOF[!NOTE] Ensure that /etc/multipath.conf contains find_multipaths no under defaults. At its default setting,
multipathddoes not create a multipath device for a LUN that has only one path, which prevents the volume from mounting.find_multipaths noapplies to the whole host, not only to QNAP volumes.multipathdwill claim every single-path block device on the node, including local disks. Apply it only on nodes intended for multipath iSCSI workloads.The
devicessection applies only to QNAP LUNs.multipathdoverrides the iSCSI timeout set by the CSI driver (replacementTimeoutin the StorageClass) with its ownfast_io_fail_tmo, which defaults to 5 seconds. With the default, a short network outage or a NAS high availability switchover can turn the filesystem read-only. Keepfast_io_fail_tmoequal to or greater thanreplacementTimeout.Enable and start the multipath service
sudo systemctl enable --now multipath-tools.service sudo service multipath-tools restartVerify that both services are active
sudo systemctl status multipath-tools sudo systemctl status open-iscsi
-
-
Verify that your NAS has at least one available storage pool and iSCSI service is enabled.
- To check storage pools on your NAS, open Storage & Snapshots and navigate to "Storage > Storage/Snapshots".
- If the iSCSI protocol is utilized. To check iSCSI service on your NAS, open iSCSI & Fibre Channel and verify that the "Service" toggle switch is on.
Verify your Kubernetes cluster.
-
Make sure
kubectlis installed and working.kubectl get pods -Akubectl versionVerify that both commands return expected results without errors.
-
Make sure that you are logged in as a Kubernetes cluster administrator.
kubectl auth can-i '*' '*' --all-namespacesThe command should return
yes. -
Verify that you can launch a pod using an image from Docker Hub and check connectivity to the storage system over the pod network.
kubectl run -i --tty ping --image=busybox --restart=Never --rm -- \ping <NAS management IP>For example:
kubectl run -i --tty ping --image=busybox --restart=Never --rm -- \ping 8.8.8.8
A successful test will display packet responses, indicating connectivity. The pod will automatically delete itself after completion.
-
Clone the git repository.
sudo git clone https://github.com/qnap-dev/QNAP-CSI-PlugIn.git -
Navigate to the directory.
cd QNAP-CSI-PlugIn -
Choose one of the following installation methods.
-
Installing via kubectl
Execute the following commands in order:
kubectl apply -f Deploy/Trident/namespace.yamlkubectl apply -f Deploy/crds/tridentorchestrator_crd.yamlkubectl apply -f Deploy/Trident/bundle.yamlkubectl apply -f Deploy/Trident/tridentorchestrator.yaml -
Installing via Kustomize
Execute the following commands in order:
kubectl apply -k Deploy/crdskubectl apply -k Deploy/Trident -
Installing via Helm
-
Install Helm.
Please refer to the Helm Installation Guide for instructions.
-
Install the CSI plugin.
helm install qnap-trident ./Helm/trident -n trident --create-namespace -
Upgrade the plugin.
helm upgrade qnap-trident Helm/trident/ -n trident
-
-
A VolumeSnapshot is required to take snapshots.
kubectl apply -k VolumeSnapshot
-
Check the status of Trident.
kubectl get deployment -n tridentThe output should display both
trident-controllerandtrident-operatoras being ready.
Example output: -
Verify the Trident service.
kubectl get service -n trident
To ensure the CSI driver functions correctly, it is important to configure the backend, secert (Optional), StorageClass, and PVC with matching labels and parameters to enable proper binding. The backend defines the virtual storage pools and connects the underlying physical resources, the secret is required when the Samba protocol is utilized for connection, while the StorageClass specifies the QoS that the PVC will request.
For binding to succeed, the PVC must reference a StorageClass that has the correct labels and selectors, which correspond to the virtual pools defined in the backend. Accurate configuration of names, labels, and selectors in each component is essential to ensure the PVC is correctly bound to the appropriate storage resources through the backend and StorageClass.
Warning
Avoid modifying CSI-provisioned resources directly through the UI. Changes made outside the CSI workflow may cause configuration mismatches between components and lead to unexpected behavior. In particular, do not map additional LUNs to an iSCSI target created by the CSI driver. The driver assumes one LUN per target and will not map a volume to a target that already has another LUN.
There are two methods for configuring the backend:
- Custom resource (
TridentBackendConfig) - CLI (
tridentctl).
Tip
We recommend using the newer custom resource method over the legacy CLI method.
-
Create or edit a YAML file (for the custom resource method) or a JSON file (for the CLI method).
Please refer to the following examples.-
Custom resource method
Example:Samples/Backend/backend-sample.yamlapiVersion: v1 kind: Secret metadata: name: backend-qts-secret # Required. Name your secret. namespace: trident type: Opaque stringData: username: user # Required. Your NAS username. password: "0000" # Required. Your NAS password. chapInitiatorUsername: <initiator_username> # Optional. Username used by the initiator to authenticate to the target. chapInitiatorPassword: <initiator_password> # Optional. Password for the initiator’s CHAP authentication. chapTargetUsername: <target_username> # Optional. Username used by the target to authenticate back to the initiator (for mutual CHAP). chapTargetPassword: <target_password> # Optional. Password for the target’s CHAP authentication (for mutual CHAP). storageAddress: "0.0.0.0" # Required. Your NAS IP address. On a QuTS hero high availability cluster, use the cluster IP. https: "false" # Optional. Whether to enable a secure connection. Default: False. port: "8080" # Optional. Specify the port. Default: 8080. trustedCACertificate: <Base64-encoded-trusted-ca-certificate-for-backend> # Optional. Base64-encoded value of trusted CA certificate. Used for certificate-based authentication. --- apiVersion: trident.qnap.io/v1 kind: TridentBackendConfig metadata: name: backend-qts # Required. Name your backend in Kubernetes. namespace: trident spec: version: 1 storageDriverName: qnap-nas #Required. Support 'qnap-nas'(latest) or 'qnap-iscsi' backendName: qts # Required. Name your backend in QNAP CSI. networkInterfaces: ["Adapter1"] # Optional. Your adapter name or leave it empty. Do not set it on a QuTS hero high availability cluster. useCHAP: true # Optional. Enables CHAP authentication for iSCSI connections. credentials: name: backend-qts-secret # Required. Enter the secret name set in metadata.name. debugTraceFlags: method: true storage: # Required. Define one or more virtual pools. - serviceLevel: pool1 # Required. Name your virtual pool. labels: # Required. Define custom labels for your virtual pool. performance: performance1 features: # Optional. Define features for your virtual pool. tiering: Enable - serviceLevel: pool2 labels: performance: performance2 features: tiering: Enable ssdCache: "true" raidLevel: "1"
-
CLI method
Example:Samples/Backend/backend-sample.json.{ "version": 1, "storageDriverName": "qnap-nas", "backendName": "qts", "storageAddress": "0.0.0.0", "username": "user", "password": "0000", "chapInitiatorUsername": "<initiator_username>", "chapInitiatorPassword": "<initiator_password>", "chapTargetUsername": "<target_username>", "chapTargetPassword": "<target_password>", "https": "false", "port": "8080", "trustedCACertificate": "<Base64-encoded-trusted-ca-certificate-for-backend>", "networkInterfaces": ["Adapter1"], "useCHAP": "true", "debugTraceFlags": {"method": true}, "storage": [ { "labels": {"performance": "performance1"}, "features":{ "tiering": "Enable" }, "serviceLevel": "pool1" }, { "labels": {"performance": "performance2"}, "features":{ "tiering": "Enable", "ssdCache": "true", "raidLevel": "1" }, "serviceLevel": "pool2" } ] }
-
Note
When a backend is registered, the driver automatically detects the operating system version of each NAS target and adapts its behavior accordingly. The version is always read from the NAS itself and cannot be declared through the backend configuration, a StorageClass, a ConfigMap, a Secret, or an environment variable.
If the version cannot be determined, the backend fails to register: it enters the Failed state and exposes no storage pools, so any PVC that resolves to it stays pending. Run the following command to check the backend state and the reported error.
./<your tridentctl path> get backend -n trident
- In the YAML or JSON file, configure the following based on your NAS settings and usage requirements.
-
Specify the correct NAS
user,password, andIP address. -
Optionally, use the
useCHAPfield to enable CHAP authentication. Providing both Initiator and Target credentials in the Secret enables mutual CHAP. For one-way CHAP, set only the Initiator credentials. -
Optionally enable HTTPS and configure the service port and trusted CA certificate according to your requirements.
-
Name the secret and backend.
-
Optional: Set the network portal in the
networkInterfacesfield.[!Note] Network settings support physical and virtual adapters. In the networkInterfaces field, assign one or multiple interface names (e.g., ["Adapter1", "Adapter2"]), or leave it empty to default to
storageAddress. To view the available adapters on your NAS, open Network & Virtual Switch and go to "Interfaces".
The number of interfaces determines the node setup. With zero or one interface, the volume has a single iSCSI path; follow the Single-Path iSCSI Setup in Installation.
If you plan to use multipath, consider the following requirements:- Configure multipath on your Kubernetes nodes. (Refer to Installation)
- Specify more than one interface in
networkInterfacesto enable redundant paths. - Use interfaces on different subnets or uplinks to improve availability and, when supported by the workload and OS policies, achieve better path distribution.
Multipath enhances reliability by providing multiple independent I/O paths. Its performance benefits depend on proper network topology, path separation, and node-side configuration.
[!IMPORTANT] QuTS hero high availability clusters: Set
storageAddressto the cluster IP and leavenetworkInterfacesunset.- Adapter names can differ between the two NAS nodes, so the same
networkInterfacesvalue may not match on the other node. - A node's own IP address stays with that node when the cluster switches over or fails over, so iSCSI sessions that use it stop working. The cluster IP always moves to the active node.
Without
networkInterfaces, each volume uses a single iSCSI path through the cluster IP. Follow the Single-Path iSCSI Setup in Installation. -
Define the virtual pools based on your usage requirements.
Field Description Example serviceLevel Name the virtual pool. serviceLevel: pool1 labels Label the virtual pool with any key/value. usage: test features Define the virtual pool with the specified features from the feature list below. features:
ssdCache: "true"Feature list:
Feature Description Value Note raidLevel Combines multiple disks to improve both redundancy and performance. 0, 1, 5, 6, etc. ssdCache Boosts NAS performance by caching frequently accessed data on SSDs, reducing latency and speeding up access. true, false tiering Moves hot data to high-performance drives and cold data to cost-efficient drives, optimizing performance and total cost of operation. enable, disable Only QTS
-
If the Samba protocol is utilized, the Secert configuration is required.
Create or edit the YAML file Samples/Secret/smb_user_secret.yaml
Example:
apiVersion: v1
kind: Secret
metadata:
name: qts-csi-smb #Required. Name your secert for Samba.
namespace: trident
type: Opaque
stringData:
username: user1 #Required. The valid Samba username on the NAS.
password: 0000 #Required. The valid Samba password on the NAS.-
Create or edit the YAML file.
iSCSI Protocol:
Samples/StorageClass/sc_iscsi_sample.yaml.Example:
apiVersion: storage.k8s.io/v1 kind: StorageClass metadata: name: storageclass1 # Required. Name your storageclass. provisioner: csi.trident.qnap.io parameters: selector: "performance=performance1" # Required. Corresponds to the labels in the virtual pool. fsType: "ext4" # Optional. You can choose to enter ext4 (default), xfs, or ext3. replacementTimeout: '120' # Optional. Define the iSCSI timeout in seconds, with a default value of 120. On multipath nodes, set fast_io_fail_tmo in /etc/multipath.conf to the same value or greater. allowVolumeExpansion: true
SMB Protocol:
Samples/StorageClass/sc_smb_sample.yaml.Example:
apiVersion: storage.k8s.io/v1 kind: StorageClass metadata: name: storageclass1 # Required. Name your storageclass. provisioner: csi.trident.qnap.io parameters: selector: "performance=performance1" # Required. Corresponds to the labels in the virtual pool. trident.qnap.io/fileProtocol: "smb" csi.storage.k8s.io/node-stage-secret-name: "qts-csi-smb" # Required. It must match the metadata.name in the Secret file. csi.storage.k8s.io/node-stage-secret-namespace: "trident" # Required. It must match the metadata.namespace in the Secret file. allowVolumeExpansion: true
-
Configure the file based on your usage requirements.
Bind the backend's virtual pool using the parameters.selector field, ensuring it matches the labels in the virtual pool.
Note
For the iSCSI protocol, when a volume is staged on a node, the CSI driver uses blkid to check whether the device already contains a filesystem. If no filesystem is present, the driver formats the device with the fsType defined in the StorageClass. If a filesystem already exists, the device is mounted as-is and no formatting is performed.
-
Create or edit the YAML file
Samples/Volumes/pvc-sample.yaml
Example:kind: PersistentVolumeClaim apiVersion: v1 metadata: name: pvc1 annotations: # Required. Define features for your volume. trident.qnap.io/Threshold: "90" trident.qnap.io/ThinAllocate: "true" spec: accessModes: - ReadWriteOnce # Required. iSCSI: ReadWriteOnce, Samba: ReadWriteMany resources: requests: storage: 10Gi # Required. Specify your resource size. storageClassName: storageclass1 # Required. Corresponds to the StorageClass name.
-
Configure the file based on your usage requirements.
-
Bind the StorageClass using the
storageClassNamefield. -
Set your volume feature requirements in the
annotationsfield using the prefixtrident.qnap.io/. For example,trident.qnap.io/Threshold: "90". Annotation names are case-sensitive; enter them exactly as listed in the following table.Volume features:
Feature Description Value Note Threshold Monitors storage usage to trigger alerts when capacity limits are reached, preventing overuse. 0-100 ThinAllocate Dynamically allocates storage space to meet demands, optimizing usage and avoiding shortages. true, false IoSyncMode Sets the I/O synchronization behavior of the volume. default, sync, async iSCSI protocol only. Refer to the note below. SharedFolderRecycleBin Enable or disable the Recycle Bin based on your needs. true, false SMB protocol only Compression Compresses files to reduce size, saving space and allowing more storage on the NAS. true, false Only QuTS hero Deduplication Eliminates duplicate data to reduce storage needs and minimize network data transfers. true, false Only QuTS hero FastClone Creates file copies faster to save space by sharing data blocks between originals and copies. true, false Only QuTS hero importOriginalName The original volume name. string Refer to Importing a PVC in the "Operations" section. importBackendName The imported backend name. string Refer to Importing a PVC in the "Operations" section.
-
Note
IoSyncMode is applied only when the volume is created, and the resulting setting depends on the operating system of the target NAS.
| IoSyncMode | QTS earlier than 6.0 | QTS 6.0 or later | QuTS hero |
|---|---|---|---|
| default | AsyncIO disabled | Synchronous by design. No configuration is required. | ZIL synchronized I/O mode: Auto |
| sync | AsyncIO disabled | Synchronous by design. No configuration is required. | ZIL synchronized I/O mode: Always |
| async | AsyncIO enabled | Not supported. Volume creation fails. | ZIL synchronized I/O mode: None |
Also note the following:
- The annotation name is case-sensitive:
trident.qnap.io/IoSyncMode. Any value other thandefault,sync, orasynccauses volume creation to fail. - Editing or removing the annotation after the PVC is bound does not change the setting of the existing volume.
- This feature is configured on the PVC only. The StorageClass does not provide an equivalent parameter.
When building the service, add the backend, the StorageClass, and then the PVC, in this order.
Make sure you have a corresponding pool, and based on the type of your backend configuration file, choose one of the following methods to add the pool.
-
Using the custom resource method to add a backend with the YAML file
a. Add a backend based on the YAML file you configured earlier.
kubectl apply -f <your backend yaml file path>For example:
kubectl apply -f Samples/Backend/backend-sample.yamlb. Check the result.
kubectl get tridentbackendconfig -n trident -
Using the CLI method to add a backend with the JSON file
a. Ensure you have permission to execute
tridentctl.chmod u+x tridentctlb. Add a backend based on the JSON file you configured earlier.
./<your tridentctl path> create backend -f <backend.json> -n tridentFor example:
./bin/linux-amd64/tridentctl create backend -f Samples/Backend/backend-sample.json -n trident
Note
If it takes over 30 seconds and shows the error "Command terminated with exit code 1" due to timeout, check your network connection and try again.
After adding the backend, check the result.
kubectl get pods -n trident
Execute the following command:
kubectl apply -f <your StorageClass yaml file path>
For example: kubectl apply -f Samples/StorageClass/sc_iscsi_sample.yaml
Note
If you want to use the SMB protocol, please execute the following command and apply the corresponding Secret before adding the StorageClass.
kubectl apply -f <your Secret yaml file path>
For example: kubectl apply -f Samples/Secret/smb_user_secret.yaml
Execute the following command:
kubectl apply -f <your pvc yaml file path>
For example: kubectl apply -f Samples/Volumes/pvc-sample.yaml
After completing the deployment steps, verify if the connection is mapped in iSCSI & Fibre Channel on the NAS. You should locate the connection in the "iSCSI Target List" on the "iSCSI Storage" page, as shown in the red frame in Figure 2.
Figure 2. Checking the iSCSI target connection.
kubectl edit pvc <your pvc name>
For example: kubectl edit pvc pvc-sample
After a few seconds, the capacity will increase on the NAS. After the pod restarts, the capacity information will be updated.
Create or edit the YAML file Samples/Volumes/pvc-clone.yaml based on your usage requirements.
Example:
apiVersion: v1
kind: PersistentVolumeClaim
metadata:
name: pvc-from-clone
spec:
accessModes:
- ReadWriteOnce # iSCSI: ReadWriteOnce, Samba: ReadWriteMany
resources:
requests:
storage: 5Gi
dataSource:
kind: PersistentVolumeClaim
name: pvc-sample
storageClassName: storageclass1Name the cloned PVC using the name field, configure the storage field, and assign the source PVC in the dataSource field.
Note
The cloned PVC's storage size must be greater than or equal to that of the source PVC.
After configuring the YAML file, run the following command:
kubectl apply -f <your pvc-clone yaml file path>
For example: kubectl apply -f Samples/Volumes/pvc-clone.yaml
iSCSI:
Create or edit the YAML file Samples/Volumes/import/pvc-import.yaml based on your usage requirements.
Important
We recommend importing only LUNs that were originally created by the QNAP CSI driver. A LUN created outside the driver may have a layout that the driver does not recognize, which can lead to unexpected errors after the import.
The LUN's existing filesystem must be one that the QNAP CSI driver supports, and should match the fsType defined in the StorageClass. Importing a LUN with an unsupported filesystem will fail.
Caution
We do not recommend importing a LUN whose iSCSI target also has other LUNs mapped. The driver assumes one LUN per target and cannot reliably identify which device belongs to the imported volume, so the node may attach and format a different LUN on the same target. Enabling multipathd does not prevent this.
Before importing, make sure the LUN is the only LUN mapped to its target.
Example:
kind: PersistentVolumeClaim
apiVersion: v1
metadata:
name: pvc-import-iscsi
namespace: default
annotations:
trident.qnap.io/importOriginalName: "test"
trident.qnap.io/importBackendName: "hero"
spec:
accessModes:
- ReadWriteOnce
resources:
requests:
storage: 10Gi
storageClassName: storageclass1After configuring the YAML file, run the following command:
kubectl apply -f <your pvc-import yaml file path>
For example: kubectl apply -f Samples/Volumes/import/pvc-import.yaml
Samba:
Create or edit the YAML file Samples/Volumes/pvc-import.yaml based on your usage requirements.
Important
We recommend importing only shared folders that were originally created by the QNAP CSI driver. A shared folder created outside the driver may have settings that the driver does not recognize, which can lead to unexpected errors after the import.
kind: PersistentVolumeClaim
apiVersion: v1
metadata:
name: pvc-import-file
annotations:
trident.qnap.io/importOriginalName: "shared-name"
trident.qnap.io/importBackendName: "qts"
spec:
accessModes:
- ReadWriteMany
resources:
requests:
storage: 10Gi # The value entered should correspond to the actual or displayed size.
storageClassName: storageclass1Note
Due to filesystem limitations in QTS, the capacity shown in "Storage & Snapshot" may be slightly smaller than the specified size when creating a shared folder. For resources.requests.storage, enter either the specified size or the displayed size.
For example:
- Specified size: 10GB
- Displayed size: 9.34GB.

In QuTS Hero, always use the specified size.
Create or edit the YAML file Samples/Snapshot/VolumeSnapshot.yaml based on your usage requirements.
Example:
apiVersion: snapshot.storage.k8s.io/v1
kind: VolumeSnapshot
metadata:
name: pvc-snapshot
spec:
volumeSnapshotClassName: trident-snapshotclass
source:
persistentVolumeClaimName: pvc-sampleAfter configuring the YAML file, run the following commands one at a time:
kubectl apply -f <VolumeSnapshotClass.yaml>
kubectl apply -f <VolumeSnapshot.yaml>
Check the result.
kubectl get volumesnapshot
Create or edit the YAML file Samples/Volumes/pvc-from-snapshot.yaml based on your usage requirements.
Example:
kind: PersistentVolumeClaim
apiVersion: v1
metadata:
name: pvc-from-snap
spec:
accessModes:
- ReadWriteOnce # iSCSI: ReadWriteOnce, Samba: ReadWriteMany
resources:
requests:
storage: 5Gi
dataSource:
name: pvc-snapshot
kind: VolumeSnapshot
apiGroup: snapshot.storage.k8s.io
storageClassName: storageclass1After configuring the YAML file, run the following command:
kubectl apply -f <pvc-from-snapshot.yaml>
Execute the following commands in order:
kubectl delete tridentorchestrator trident
kubectl apply -f Deploy/Trident/tridentorchestrator.yaml
-
Uninstalling via Kustomize (normal method)
Execute the following commands in order:kubectl delete deployment trident-operator -n trident./<your tridentctl path> uninstall -n tridentkubectl delete tridentorchestrator trident -
Uninstalling via Helm
helm delete qnap-trident -n trident
The pod event looks like this:
rpc error: code = Internal desc = ... multipath device not found when it is expected
The worker node has the multipath command installed, so the driver requires a multipath device for the volume, but multipathd has not created one.
Check how many interfaces the backend declares in spec.networkInterfaces of its TridentBackendConfig:
- Zero or one interface. The volume has a single iSCSI path. At its default setting,
multipathdnever creates a multipath device for a single-path LUN. The tooling is usually present because the distribution installed it, not because it was configured.
What to do: remove multipath tooling from the worker node, or setfind_multipaths noand restartmultipathd. See Single-Path iSCSI Setup in Installation. - Two or more interfaces.
multipathdis not running, orfind_multipathsis still at its default setting.
What to do: setfind_multipaths noin/etc/multipath.confand restartmultipathd. See Multipath iSCSI Setup in Installation.
To check the node:
multipath -ll
systemctl status multipathd
A node that prints nothing for multipath -ll but still has the command installed is the first case above.
A pod event says "node does not support multipath; device number should be one, currently N device(s)"
The backend declares more than one network interface, so the volume has several iSCSI paths, but the worker node has no multipath tooling to combine them into one device.
Install and configure multipath tooling on the node as described in Multipath iSCSI Setup in Installation, or reduce the backend to a single network interface.