25 changes: 13 additions & 12 deletions packages/control/chargepoint/chargepoint.py
Original file line number Diff line number Diff line change
Expand Up @@ -519,19 +519,20 @@ def set_phases(self, phases: int, template_phases: int) -> int:
phases = min(phases, self.get_max_phase_hw())

if phases != self.data.get.phases_in_use:
# Wenn noch kein Eintrag im Protokoll erstellt wurde, wurde noch nicht geladen und die Phase kann noch
# umgeschaltet werden.
if self.data.set.log.imported_since_plugged != 0 and charging_ev.ev_template.data.prevent_phase_switch:
log.info(f"Phasenumschaltung an Ladepunkt {self.num} nicht möglich, da bei EV"
f"{charging_ev.num} nach Ladestart nicht mehr umgeschaltet werden darf.")
if self.data.get.phases_in_use != 0:
if self.data.set.log.imported_since_plugged != 0:
if self.hw_supports_phase_switch() is False:
# sonst passt die Phasenzahl nicht bei Autos, die eine Phase weg schalten.
log.info(f"Phasenumschaltung an Ladepunkt {self.num} wird durch die Hardware nicht unterstützt.")
phases = self.data.get.phases_in_use
else:
phases = self.data.control_parameter.phases
elif self.hw_supports_phase_switch() is False:
# sonst passt die Phasenzahl nicht bei Autos, die eine Phase weg schalten.
log.info(f"Phasenumschaltung an Ladepunkt {self.num} wird durch die Hardware nicht unterstützt.")
phases = self.data.get.phases_in_use
if charging_ev.ev_template.data.prevent_phase_switch:
# Wenn noch kein Eintrag im Protokoll erstellt wurde, wurde noch nicht geladen und die Phase kann
# noch umgeschaltet werden.
log.info(f"Phasenumschaltung an Ladepunkt {self.num} nicht möglich, da bei EV"
f"{charging_ev.num} nach Ladestart nicht mehr umgeschaltet werden darf.")
if self.data.get.phases_in_use != 0:
phases = self.data.get.phases_in_use
else:
phases = self.data.control_parameter.phases
if phases != self.data.control_parameter.phases:
self.data.control_parameter.phases = phases
self.data.control_parameter.template_phases = template_phases
Expand Down
11 changes: 9 additions & 2 deletions packages/control/chargepoint/get_phases_test.py
Original file line number Diff line number Diff line change
Expand Up @@ -153,8 +153,15 @@ def __init__(self,
imported_since_plugged=1, phase_switch_supported=True, expected_phases=3),
SetPhasesParams(name="Switch phases", phases=1, phases_in_use=3, prevent_phase_switch=False,
imported_since_plugged=1, phase_switch_supported=True, expected_phases=1),
SetPhasesParams(name="Phase switch not supported by cp", phases=1, phases_in_use=3, prevent_phase_switch=False,
imported_since_plugged=1, phase_switch_supported=False, expected_phases=3)
SetPhasesParams(name="Phase switch not supported by cp, use phases in use after charge start",
# aktuelle Phasenzahl verwenden, sonst passt die Phasenzahl nicht bei Autos,
# die eine Phase weg schalten.
phases=1, phases_in_use=3, prevent_phase_switch=False,
imported_since_plugged=1, phase_switch_supported=False, expected_phases=3),
SetPhasesParams(name="Phase switch not supported by cp, use passed phases before start",
# vor dem Ladestart die konfigurierte Phasenzahl verwenden
phases=1, phases_in_use=3, prevent_phase_switch=False,
imported_since_plugged=0, phase_switch_supported=False, expected_phases=1)
]


Expand Down
Loading