8 changes: 6 additions & 2 deletions packages/control/chargepoint/chargepoint.py
Original file line number Diff line number Diff line change
Expand Up @@ -248,6 +248,7 @@ def remember_previous_values(self):
self.data.set.plug_state_prev = self.data.get.plug_state
self.data.set.current_prev = self.data.set.current
self.data.set.ev_prev = self.data.config.ev
self.data.set.state_prev = self.data.control_parameter.state

def reset_log_data_chargemode_switch(self) -> None:
reset_log = Log()
Expand Down Expand Up @@ -284,9 +285,12 @@ def initiate_control_pilot_interruption(self):
if self.data.config.control_pilot_interruption_hw:
control_parameter = self.data.control_parameter
retry_interval = charging_ev.ev_template.data.control_pilot_interruption_retry_interval
# Wird die Ladung gestartet? (nicht nach Phasenumschaltung, da diese bereits CP umschaltet)
# Wird die Ladung gestartet? Nicht, wenn eine Phasenumschaltung gerade lief oder jetzt
# ansteht - die schaltet CP bereits selbst um (state_prev statt state, da
# WAIT_FOR_USING_PHASES auch unabhängig von einer Umschaltung erreicht wird).
started_now = (self.data.set.current_prev == 0 and self.data.set.current != 0 and
self.data.control_parameter.state != ChargepointState.WAIT_FOR_USING_PHASES)
self.data.set.state_prev != ChargepointState.PERFORMING_PHASE_SWITCH and
self._is_phase_switch_required() is False)
# Ladung angefordert, Auto lädt aber trotz gültigem Signal seit geraumer Zeit nicht.
stuck = (
retry_interval > 0 and
Expand Down
6 changes: 6 additions & 0 deletions packages/control/chargepoint/chargepoint_data.py
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,7 @@
from threading import Event
from typing import Dict, List, Optional, Protocol
from control.chargemode import Chargemode
from control.chargepoint.chargepoint_state import ChargepointState
from control.chargepoint.chargepoint_template import CpTemplate

from control.chargepoint.control_parameter import ControlParameter, control_parameter_factory
Expand Down Expand Up @@ -174,6 +175,11 @@ class Set:
charging_ev_data: Ev = field(default_factory=ev_factory)
ocpp_transaction_id: Optional[int] = field(default=None, metadata={"topic": "set/ocpp_transaction_id"})
charge_state_prev: bool = field(default=False, metadata={"topic": "set/charge_state_prev"})
# control_parameter.state aus dem vorherigen Zyklus, um eine Control-Pilot-Unterbrechung beim
# Ladestart von einer, die direkt nach einer echten Phasenumschaltung erfolgt, zu unterscheiden
# (siehe initiate_control_pilot_interruption()).
state_prev: ChargepointState = field(default=ChargepointState.NO_CHARGING_ALLOWED,
metadata={"topic": "set/state_prev"})
# letzter CP-SoC-Timestamp, für den bereits ein force_soc_update ausgelöst wurde, und das zugehörige EV,
# um bei dauerhaft veraltetem EV-SoC (zB API-Fehler) nicht jeden Zyklus erneut ein Update anzustoßen,
# aber bei einem EV-Wechsel am selben Ladepunkt trotzdem einmal neu auszulösen
Expand Down
69 changes: 69 additions & 0 deletions packages/control/chargepoint/chargepoint_test.py
Original file line number Diff line number Diff line change
Expand Up @@ -68,6 +68,75 @@ def test_check_min_max_current(required_current, phases, expected_required_curre
assert ret == expected_required_current


@pytest.mark.parametrize("state_prev, expected_message_present",
[
pytest.param(ChargepointState.SWITCH_ON_DELAY, True,
id="Ladestart nach Einschaltverzoegerung: CP-Unterbrechung noetig"),
pytest.param(ChargepointState.NO_CHARGING_ALLOWED, True,
id="regulaerer Ladestart: CP-Unterbrechung noetig"),
pytest.param(ChargepointState.PERFORMING_PHASE_SWITCH, False,
id="direkt nach Phasenumschaltung: keine zusaetzliche CP-Unterbrechung"),
])
def test_initiate_control_pilot_interruption_uses_state_prev_not_state(state_prev, expected_message_present):
""" WAIT_FOR_USING_PHASES wird nicht nur direkt nach einer echten Phasenumschaltung erreicht, sondern
zB auch direkt nach Ablauf der Einschaltverzoegerung (siehe Discussion #3908, lackylacky) - dort war
dann also nach jedem PV-Ladestart mit reiner Ein-Phasen-Ladung (kein hw_supports_phase_switch())
dauerhaft keine Control-Pilot-Unterbrechung mehr moeglich. state_prev unterscheidet die beiden
Faelle korrekt, state (aktuell WAIT_FOR_USING_PHASES in beiden Faellen) nicht. """
# setup
cp = Chargepoint(0, None)
cp.chargepoint_module = Mock(interrupt_cp=Mock(), config=Mock(id=0))
cp.data.set.charging_ev_data = Ev(0)
cp.data.set.charging_ev_data.ev_template.data.control_pilot_interruption = True
cp.data.set.charging_ev_data.ev_template.data.control_pilot_interruption_duration = 4
cp.data.set.charging_ev_data.ev_template.data.control_pilot_interruption_retry_interval = 0
cp.data.config.control_pilot_interruption_hw = True
# state_prev ueber remember_previous_values() setzen statt direkt zuzuweisen
cp.data.set.current = 0
cp.data.control_parameter.state = state_prev
cp.remember_previous_values()
# aktueller Zyklus: Ladung startet
cp.data.control_parameter.state = ChargepointState.WAIT_FOR_USING_PHASES
cp.data.set.current = 6

# evaluation
cp.initiate_control_pilot_interruption()

# assertion
message_present = (cp.data.get.state_str is not None and
"Control-Pilot-Unterbrechung" in cp.data.get.state_str)
assert message_present == expected_message_present


def test_initiate_control_pilot_interruption_skipped_when_phase_switch_pending():
""" Kontaktoren stehen noch auf falscher Phasenzahl -> initiate_phase_switch() schaltet im selben
Zyklus bereits CP um, keine zusaetzliche Unterbrechung noetig. """
# setup
cp = Chargepoint(0, None)
cp.chargepoint_module = Mock(interrupt_cp=Mock(), config=Mock(id=0))
cp.data.set.charging_ev_data = Ev(0)
cp.data.set.charging_ev_data.ev_template.data.control_pilot_interruption = True
cp.data.set.charging_ev_data.ev_template.data.control_pilot_interruption_duration = 4
cp.data.set.charging_ev_data.ev_template.data.control_pilot_interruption_retry_interval = 0
cp.data.config.control_pilot_interruption_hw = True
cp.data.set.current = 0
cp.data.control_parameter.state = ChargepointState.SWITCH_ON_DELAY
cp.remember_previous_values()
cp.data.control_parameter.state = ChargepointState.WAIT_FOR_USING_PHASES
cp.data.set.current = 6
# Kontaktoren (1p) weichen von der benoetigten Phasenzahl (3p) ab
cp.data.set.phases_to_use = 3
cp.data.control_parameter.phases = 1

# evaluation
cp.initiate_control_pilot_interruption()

# assertion
message_present = (cp.data.get.state_str is not None and
"Control-Pilot-Unterbrechung" in cp.data.get.state_str)
assert message_present is False


@pytest.mark.parametrize("required_current, max_discharge_power, dc_max_current, expected_required_current",
[
pytest.param(-50, -30000, 25, -25,
Expand Down
2 changes: 2 additions & 0 deletions packages/helpermodules/setdata.py
Original file line number Diff line number Diff line change
Expand Up @@ -497,6 +497,8 @@ def process_chargepoint_topic(self, msg: mqtt.MQTTMessage):
"/set/charge_state_prev" in msg.topic or
"/set/plug_state_prev" in msg.topic):
self._validate_value(msg, bool)
elif "/set/state_prev" in msg.topic:
self._validate_value(msg, int, [(0, 7)])
elif "/set/autolock_state" in msg.topic:
self._validate_value(msg, int, [(0, 4)])
elif "/set/rfid" in msg.topic:
Expand Down
Loading