Fix Tesla/Powerwall data handling and improve robustness of control loop - #3232
Conversation
…d gateway diagnostics - add structured HTTP error handling in PowerwallHttpClient - distinguish transport, HTTP and JSON parsing failures - support fail_fast=False for non-critical requests - track cycle_failed and cookie_renewed state across one polling cycle - add fail-fast handling in device.py - stop remaining Tesla component updates once a critical Powerwall request fails - log native TCP connection state diagnostics via /proc/net/tcp(/tcp6) - emit periodic session / connection health logs - keep cookie reuse, but mark startup + reauth cycles explicitly - reduce /api/status traffic in counter.py - fetch firmware only after startup or after a new auth cookie was negotiated - treat /api/status as non-critical so it cannot fail the whole cycle - keep import/export counters based on aggregate["site"]["energy_imported/exported"] - do not use summed per-phase energy counters as meter source - keep /api/meters/site for phase details only - add derived fallback currents and signed power factors from P/Q/U when Tesla/Neurio currents are 0 - expose additional diagnostics such as frequency / serial number - add throttled debug logging to compare aggregate counters with per-phase sums - restore aggregate-based site counters so load management works correctly again
LKuemmel
left a comment
There was a problem hiding this comment.
Leider bläht dein PR den Code ganz schon auf. Von 154 Zeilen für die drei Python-Dateien auf 565.
Einige Punkte sind zentral gelöst, andere sind für den Entwickler des Moduls interressant, müssen aber nicht dauerhaft im Code enthalten sein.
Wichtig ist, dass der Code wartbar und verständlich bleibt. Gibt es konkrete Probleme mit der Powerwall, die du mit deinem PR lösen willst?
| # If all API currents are 0 -> use calculated currents | ||
| if all(self._nearly_zero(i) for i in api_currents): | ||
| currents = calculated_currents | ||
| log.debug( | ||
| "Tesla/Neurio phase currents missing (all 0). Calculated currents from P/Q and U." | ||
| ) | ||
| else: | ||
| currents = api_currents | ||
| # PF still useful even if currents exist | ||
| log.debug("Using phase currents from Tesla/Neurio API.") |
There was a problem hiding this comment.
Wenn es Modelle gibt, die keine Ströme liefern, dann dürfen diese im CounterState nicht gesetzt werden. Dann werden sie automatisch gesetzt.
| def _nearly_zero(x: float, eps: float = 1e-9) -> bool: | ||
| return abs(x) < eps | ||
|
|
||
| def _calc_currents_and_pf_from_pqu( |
There was a problem hiding this comment.
Diese Berechnung erfolgt zentral im CounterState, wenn keine Ströme gesetzt sind, aber Phasenspannungen und Phasenleistungen vorhanden sind. Die Berechnung soll nicht in jedem Modul erfolgen.
There was a problem hiding this comment.
Im CounterState sind jedoch nur die Wirkleistungen vorhanden. Reale Ströme können dann nicht berechnet werden. Das sollte in einem anderen PR grundlegend überarbeitet werden.
There was a problem hiding this comment.
Danke für den Hinweis.
Dann würde ich für diesen PR die lokale Stromberechnung im Tesla-Counter beibehalten. In meinem Setup liefert Tesla/Neurio für die Phase currents nur 0-Werte, und ohne diese Ableitung funktioniert das Lastmanagement nicht zuverlässig.
Den generischen Ansatz zur Berechnung realer currents im CounterState würde ich nicht in diesem PR lösen. Das wäre aus meiner Sicht ein separates Thema, wie von dir vorgeschlagen.
Ich reduziere den PR daher weiter auf:
reduzierte /api/status-Nutzung
schlankes fail-fast
Tesla-spezifische Stromableitung nur dort, wo die API keine brauchbaren currents liefert
Ist das in eurem Interesse?
There was a problem hiding this comment.
Ich habe das bei mir umgesetzt und teste die Änderungen über Ostern. Anschließend würde ich den PR aktualisieren...
| self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config)) | ||
|
|
||
| @staticmethod | ||
| def _safe_float(val, default: float = 0.0) -> float: |
There was a problem hiding this comment.
Default Werte werden zentral im CounterState gesetzt, damit sie konsistent sind.
There was a problem hiding this comment.
Bitte die Methode entfernen. Wenn Werte in einem Zyklus fehlen, wird eine Exception geworfen.
Es wird inkonsistent und der Code in jedem Modul sehr umfangreich, wenn überall default-Werte gesetzt werden.
There was a problem hiding this comment.
Erledigt. _safe_float() und die lokalen Default-Werte habe ich entfernt. Fehlende bzw. nicht konvertierbare Werte laufen jetzt über den bestehenden Exception-/Fallback-Pfad.
Zusätzlich wird HTTPError im Counter nicht mehr abgefangen, damit HTTP-/Kommunikationsfehler durch das zentrale Error-Handling verarbeitet werden.
…andling - remove session / connection diagnostics and analysis-only helpers - remove /proc-based connection stats and periodic session logging - keep fail-fast handling for the Tesla update cycle - keep cookie reuse and 401/403 reauthentication flow - keep support for non-critical requests via fail_fast=False - reduce implementation closer to upstream while preserving Powerwall-specific fixes
|
Hallo LKuemmel, für die Entwicklung und Optimierung der Schnittstelle hatte ich einige Debug und Testfunktionen implementiert. Die habe ich nun wieder entfernt (siehe meine PR-Aktualisierung 2d479e0). |
|
Meine Tests über das Osterwochenende sind erfolgreich verlaufen. Es wäre nett, wenn ihr nochmals einen Review durchführt. |
| self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config)) | ||
|
|
||
| @staticmethod | ||
| def _safe_float(val, default: float = 0.0) -> float: |
There was a problem hiding this comment.
Bitte die Methode entfernen. Wenn Werte in einem Zyklus fehlen, wird eine Exception geworfen.
Es wird inkonsistent und der Code in jedem Modul sehr umfangreich, wenn überall default-Werte gesetzt werden.
| need_status = False | ||
| if getattr(client, "cookie_renewed", False): | ||
| need_status = True | ||
| elif not getattr(self.store, "firmware", ""): | ||
| need_status = True | ||
|
|
||
| if need_status: | ||
| try: | ||
| status = client.get_json("/api/status", fail_fast=False) | ||
| self.store.firmware = status.get("version", "") | ||
| log.debug("Firmware: %s", self.store.firmware) | ||
| except Exception: | ||
| # /api/status is non-critical and must not trigger fail-fast | ||
| pass | ||
|
|
There was a problem hiding this comment.
Ist es nicht sinnvoller, die Firmware-Version in der initializer-Methode der device.py aufzurufen?
Die Firmware-Version wird ohnehin nur im Log aufgerufen und hat keinen weiteren Nutzen.
There was a problem hiding this comment.
Ja, das ist aus meiner Sicht sinnvoller. Die Firmware-Version ist nicht regelungsrelevant und sollte daher nicht im regulären Update-Zyklus abgefragt werden.
Ich nehme die /api/status-Abfrage aus dem Counter-Update heraus und verschiebe sie in die initializer-Methode.
There was a problem hiding this comment.
Danke für den Hinweis. Ich nehme die lokale Default-Wert-Behandlung an dieser Stelle wieder heraus, damit fehlende oder unvollständige Werte konsistent über den bestehenden Exception-/Fallback-Pfad behandelt werden.
Mein Ziel war hier vor allem, auf inkonsistente Tesla/Neurio-Antworten robuster zu reagieren. Ich richte mich im PR aber nach der zentralen openWB-Logik und reduziere die lokale Sonderbehandlung wieder.
| def _ensure_initialized(): | ||
| nonlocal http_client, session | ||
| if session is None or http_client is None: | ||
| initializer() | ||
| if session is None or http_client is None: | ||
| raise Exception("Powerwall device initializer did not create session/http_client") | ||
|
|
There was a problem hiding this comment.
Bitte entfernen, wird zentral gelöst.
Wenn bei einer Exception der initializer aufgerufen werden soll, in Z. 113 den Parameter error_handler mit initializer initialisieren.
There was a problem hiding this comment.
Danke für den Hinweis. Ich entferne die lokale Initialisierungs-Hilfslogik wieder, damit das Modul näher an der zentralen openWB-Struktur bleibt.
Falls eine Reinitialisierung bei Fehlern weiterhin nötig ist, binde ich das wie vorgeschlagen über den error_handler mit initializer an, statt es lokal im Modul zu behandeln.
| # Fail-fast marker for the current polling cycle | ||
| self.cycle_failed = False | ||
|
|
||
| # Marker: set when a new auth cookie was negotiated (startup or reauth) | ||
| self.cookie_renewed = False | ||
|
|
||
| def reset_cycle(self): | ||
| """Reset per update-cycle flags.""" | ||
| self.cycle_failed = False | ||
| self.cookie_renewed = False | ||
|
|
||
| def mark_cookie_renewed(self): | ||
| """Mark that cookies have been freshly negotiated (start or reauth).""" | ||
| self.cookie_renewed = True | ||
|
|
||
| def get_json(self, relative_url: str, *, fail_fast: bool = True): | ||
| """ | ||
| :param fail_fast: | ||
| True -> errors mark this cycle as failed (device aborts remaining components) | ||
| False -> errors do NOT mark cycle_failed (for non-critical endpoints like /api/status) | ||
| """ | ||
| url = self.__base_url + relative_url | ||
| return self.__session.get(url, cookies=self.cookies, verify=False, timeout=5).json() | ||
|
|
||
| try: | ||
| response = self.__session.get( | ||
| url, | ||
| cookies=self.cookies, | ||
| verify=False, | ||
| timeout=5, | ||
| ) | ||
| return response.json() | ||
| except (HTTPError, Timeout, ConnectionError, SSLError, RequestException, ValueError): | ||
| if fail_fast: | ||
| self.cycle_failed = True | ||
| raise No newline at end of file |
There was a problem hiding this comment.
Bitte die Änderungen entfernen, diese blähen den Code stark auf, ohne einen wirklichen Mehrwert zu bieten.
There was a problem hiding this comment.
Verstanden. Ich reduziere die Änderungen an dieser Stelle wieder deutlich.
Mein Ziel war hier, konkrete Probleme im Tesla-/Powerwall-Modul zu adressieren. Für den PR lasse ich aber nur die Teile stehen, die dafür funktional wirklich notwendig sind, und nehme die übrigen Erweiterungen wieder heraus.
…allback - remove analysis-only diagnostics and session tracking from device.py - remove connection stats and other debug-only helpers - simplify http_client.py to a minimal request wrapper - keep cookie reuse and 401/403 reauthentication flow in device.py - use fail-fast handling in device.py via SingleComponentUpdateContext(..., reraise=True) - move Tesla-specific robustness back into the counter module only - keep aggregate["site"]["energy_imported/exported"] as sole source for EVU counters - keep local current and power factor calculation when Neurio/Tesla returns only 0 currents - remove /api/status handling from counter.py - fix formatting / lint issues (newline at EOF, spaces instead of tabs)
| return default | ||
| return float(val) | ||
| except (TypeError, ValueError): | ||
| return default |
There was a problem hiding this comment.
Die Methode und die Aufrufe kann entfallen, das ist zentral umgesetzt.
There was a problem hiding this comment.
Danke, ich entferne _safe_float() und verlasse mich auf die zentrale Behandlung. Mein ursprünglicher Gedanke war, unvollständige Tesla-Antworten robuster abzufangen.
| try: | ||
| # For Tesla/Powerwall we want fail-fast behaviour: | ||
| # if one critical component update fails (especially EVU / house transition point), | ||
| # abort the remaining Tesla component updates in this cycle. | ||
| with SingleComponentUpdateContext(component.fault_state, reraise=True): | ||
| component.update(client, aggregate) | ||
| except Exception: | ||
| break |
There was a problem hiding this comment.
| try: | |
| # For Tesla/Powerwall we want fail-fast behaviour: | |
| # if one critical component update fails (especially EVU / house transition point), | |
| # abort the remaining Tesla component updates in this cycle. | |
| with SingleComponentUpdateContext(component.fault_state, reraise=True): | |
| component.update(client, aggregate) | |
| except Exception: | |
| break | |
| with SingleComponentUpdateContext(component.fault_state, reraise=True): | |
| component.update(client, aggregate) |
Das bricht mit der bestehenden Logik. Wenn eine Komponente nicht auslesbar ist, müssen alle anderen trotzdem ausgelesen werden, sonst kommen sie nicht in den Fehlerzustand oder wenn sie Werte liefern, braucht die Regelung diese.
There was a problem hiding this comment.
Ich verstehe den Einwand zum break im Komponentenloop. Ich würde das Verhalten gern präzisieren:
Bei Parsing-/Datenfehlern innerhalb einer einzelnen Komponente soll kein fail-fast erfolgen; dann soll die jeweilige Komponente über den bestehenden Fehlerpfad fehlschlagen und die übrigen Komponenten sollen weiter verarbeitet werden.
Fail-fast soll nur bei Gateway-/Transportfehlern greifen, also wenn die Powerwall/Gateway-Kommunikation selbst fehlschlägt. In diesem Fall hängen alle Tesla-Komponenten an derselben nicht erreichbaren Quelle, weitere Abfragen im selben Zyklus erzeugen nur zusätzliche Timeouts und verzögern die Regelschleife.
Ich würde die Änderung entsprechend anpassen, sodass nur Verbindungs-/Gatewayfehler den Tesla-Zyklus abbrechen, nicht aber komponentenspezifische Parsing- oder Datenfehler. Ist das in eurem Interesse?
There was a problem hiding this comment.
Bitte kein modulspezifisches Error-Handling implementieren. Das Error-Handling erfolgt zentral. Bei der Vielzahl der Module ist das sonst nicht wartbar.
Wenn die Powerwall nicht erreichbar ist, wird __update_components abgebrochen und die Modul-Updates nicht mehr aufgerufen.
There was a problem hiding this comment.
Danke für die Klarstellung. Ich habe das modulspezifische Fail-Fast jetzt vollständig entfernt.
__update_components() liest zunächst zentral /api/meters/aggregates. Ist die Powerwall nicht erreichbar, schlägt bereits dieser Aufruf fehl und die einzelnen Komponenten-Updates werden nicht mehr aufgerufen.
Im Komponentenloop verwende ich wieder den normalen SingleComponentUpdateContext ohne reraise=True, sodass Fehler einzelner Komponenten über die bestehende zentrale Logik behandelt werden und die übrigen Komponenten weiterhin aktualisiert werden können.
| timeout=5, | ||
| ) | ||
| log.debug("Authentication endpoint send cookies %s", str(response.cookies)) | ||
| response.raise_for_status() |
There was a problem hiding this comment.
| response.raise_for_status() |
Wird über einen Hook aufgerufen.
| <div class="alert alert-success"> | ||
| Anmeldung erfolgreich!<br> | ||
| Die erhaltenen Token wurden gespeichert. Du kannst diese Seite jetzt schließen. | ||
| Die erhaltenen Token wurden gespeichert. Sie können diese Seite jetzt schließen. |
There was a problem hiding this comment.
Im UI wird Du als Ansprache verwendet.
- use central openWB component error handling - remove Tesla-specific fail-fast handling - rely on the shared HTTP response hook - remove obsolete local API compatibility warning
- remove _safe_float and module-specific defaults - propagate HTTP errors to central error handling - keep compatibility fallback for missing phase data - calculate phase currents from P/Q/U when Tesla reports zero currents
|
Hallo @LKuemmel,
Die Änderungen habe ich anschließend nochmals an meiner Powerwall 2 / Backup Gateway 2 getestet. |
LKuemmel
left a comment
There was a problem hiding this comment.
Bitte noch die Flake8 Meldungen beseitigen, dann kann der PR so rein.
…oop (openWB#3232) * tesla/powerwall: implement load management, add fail-fast handling and gateway diagnostics - add structured HTTP error handling in PowerwallHttpClient - distinguish transport, HTTP and JSON parsing failures - support fail_fast=False for non-critical requests - track cycle_failed and cookie_renewed state across one polling cycle - add fail-fast handling in device.py - stop remaining Tesla component updates once a critical Powerwall request fails - log native TCP connection state diagnostics via /proc/net/tcp(/tcp6) - emit periodic session / connection health logs - keep cookie reuse, but mark startup + reauth cycles explicitly - reduce /api/status traffic in counter.py - fetch firmware only after startup or after a new auth cookie was negotiated - treat /api/status as non-critical so it cannot fail the whole cycle - keep import/export counters based on aggregate["site"]["energy_imported/exported"] - do not use summed per-phase energy counters as meter source - keep /api/meters/site for phase details only - add derived fallback currents and signed power factors from P/Q/U when Tesla/Neurio currents are 0 - expose additional diagnostics such as frequency / serial number - add throttled debug logging to compare aggregate counters with per-phase sums - restore aggregate-based site counters so load management works correctly again * tesla/powerwall: simplify device/http client and keep cookie reauth handling - remove session / connection diagnostics and analysis-only helpers - remove /proc-based connection stats and periodic session logging - keep fail-fast handling for the Tesla update cycle - keep cookie reuse and 401/403 reauthentication flow - keep support for non-critical requests via fail_fast=False - reduce implementation closer to upstream while preserving Powerwall-specific fixes * tesla/powerwall: simplify device/http client and keep local current fallback - remove analysis-only diagnostics and session tracking from device.py - remove connection stats and other debug-only helpers - simplify http_client.py to a minimal request wrapper - keep cookie reuse and 401/403 reauthentication flow in device.py - use fail-fast handling in device.py via SingleComponentUpdateContext(..., reraise=True) - move Tesla-specific robustness back into the counter module only - keep aggregate["site"]["energy_imported/exported"] as sole source for EVU counters - keep local current and power factor calculation when Neurio/Tesla returns only 0 currents - remove /api/status handling from counter.py - fix formatting / lint issues (newline at EOF, spaces instead of tabs) * Fix Tesla error handling and compatibility note - use central openWB component error handling - remove Tesla-specific fail-fast handling - rely on the shared HTTP response hook - remove obsolete local API compatibility warning * se standard error handling in Tesla counter - remove _safe_float and module-specific defaults - propagate HTTP errors to central error handling - keep compatibility fallback for missing phase data - calculate phase currents from P/Q/U when Tesla reports zero currents * Fix Tesla module lint errors * Adjust Tesla API compatibility note
* dimm kit: improve error handling, handle deleted output devices (#3868) * dimm kit: improve error handling, handle deleted output devices * review, complete logging * Apply batched suggestions from code review Co-authored-by: Copilot Autofix powered by AI <175728472+Copilot@users.noreply.github.com> * fixes * add pytest --------- Co-authored-by: Copilot Autofix powered by AI <175728472+Copilot@users.noreply.github.com> * PV-Reset: NO_CHARGING_ALLOWED blockiert den robustness-Reset nicht mehr (#3968) Nach PR #3966 blockierte ein eingesteckter, aber unterhalb der Einschaltschwelle wartender Ladepunkt (Zustand NO_CHARGING_ALLOWED) weiterhin dauerhaft den Reset von reserved_surplus/released_surplus - das ist aber der mit Abstand häufigste, langlebigste Zustand eines PV-ladenden Fahrzeugs. Jede Reservierung wird jedoch bereits beim Übergang in diesen Zustand freigegeben (siehe zB Counter.reset_switch_on_off()), sodass er nie mit einer noch offenen Reservierung erreicht wird - er gehörte also nie in die Blockierliste. Betroffen war zB ein Fall, in dem eine verwaiste reserved_surplus-Reservierung aus einem unterbrochenen Vorgang nie mehr zurückgesetzt wurde, wodurch die Einschaltschwelle dauerhaft nicht mehr erreicht werden konnte (PV-Laden startet gar nicht mehr) - siehe Diskussion. Ersetzt die 5 Einzelvergleiche + Chargepoint/Consumer-Fallunterscheidung + plug_state-Sonderfall durch eine einzige Zustandsliste der tatsächlich reservierungshaltenden Zustände (PERFORMING_PHASE_SWITCH, PHASE_SWITCH_DELAY, SWITCH_OFF_DELAY, SWITCH_ON_DELAY), verifiziert gegen jede +=/-=-Stelle in counter.py/ev.py/chargepoint.py. references #3908 (reply in thread) * fix: external_openwb chargepoint crashes when fault_state topic is missing (#3970) get_values() indexed received_topics[fault_state] directly, including inside its own KeyError handler - if the paired internal chargepoint hadn't published fault_state yet (startup, reconnect), the fallback crashed on the exact same missing key instead of handling it. * consumer: fix hierarchy, default usage (#3975) * consumer: fix hierarchy, default usage * Potential fix for pull request finding Co-authored-by: Copilot Autofix powered by AI <175728472+Copilot@users.noreply.github.com> --------- Co-authored-by: Copilot Autofix powered by AI <175728472+Copilot@users.noreply.github.com> * fix: external_openwb occasionally missed retained MQTT topics under load (#3976) start_finite_loop()'s fixed 1s collection window left little margin for connection/handshake overhead when the paired internal chargepoint was busy (eg mid-charge), occasionally causing get_values() to miss a retained topic despite retain=True. Made the timeout configurable (default unchanged for the other 17 call sites) and doubled it for external_openwb specifically, which has to reliably collect ~20 topics over a real network hop rather than one or two local values. * Systembericht Verbraucher (#3956) * add consumers; reorganize structure * improve * fix: Ladepunkte nutzen die Abschaltschwelle der Verbraucher (#3984) calc_switch_off_threshold() liest fuer alle Lasten surplus.consumer.switch_off_threshold. surplus.vehicle.switch_off_threshold ist konfigurierbar, wird migriert und in der Debug-Ausgabe angezeigt, aber im Regelalgorithmus nirgends gelesen. Die Migration verschiebt den alten pv_charging/switch_off_threshold nach surplus/vehicle/switch_off_threshold. Damit regeln bestehende Anlagen seit dem Update mit dem neu angelegten Consumer-Default 0 statt mit dem konfigurierten Wert. * removing meter-only consumers from load management priority (#3998) * removing meter-only consumers from load management priority * review * extend for self_controlled * Potential fix for pull request finding 'Preserve pre-existing empty groups during migration' Co-authored-by: Copilot Autofix powered by AI <175728472+Copilot@users.noreply.github.com> --------- Co-authored-by: Copilot Autofix powered by AI <175728472+Copilot@users.noreply.github.com> * build UI (#3999) * Update: Hausverbrauch Zähler (#3991) * EVU auf Auto entspricht Ja * fix * avm: fix consumer switch_on/off using unresolved ain, fix bare return in session lookup (#3987) * build UI (#4000) * Feature negative dc charging (#3795) * Add Bidi to instant-charging * Update Koala-UI min/max DC-Sollleistung * fix * Build Themes * avm consumer: invertierte Session-Refresh-Bedingung beheben (#4001) ensure_valid_session_id() erneuerte die Session nur, wenn check_valid_session_id() False war - die Funktion liefert aber "ist ungültig" zurück, nicht "ist gültig". Dadurch wurde nie erneuert, sobald session_id einmal None oder abgelaufen war: alle Anfragen liefen dauerhaft mit sid=None und schlugen mit HTTP 403 fehl. Umbenannt zu session_id_expired(), passend zum tatsächlichen Rückgabewert. * Peak Filter: bei Rückwärtssprüngen auf Wert größer/gleich Höchststand warten (#4007) * Peak Filter: bei Rückwärtssprüngen auf Wert größer/gleich Höchststand warten * review * build UI (#4008) * Consumer: Add Daikin, EGO and EMS-ESP (#3969) * Add Daikin, EGO and EMS-ESP consumer modules * daikin: Air2Air-Fixes aus Review (Lena, PR #3969) + neues Altherma-Modul Air2Air: Name korrigiert ("Daikin Air2Air (HomeHub EKRHH)"), METER_ONLY entfernt (keine Leistungsmessung verfügbar). Neu: daikin_homehub_altherma - eigenes Modul für Daikin Altherma, da eigene Modbus-Register (EKRHH Installer Reference Guide 4PDE744838, Kap. 9, separat von Air2Air/Kap. 10). Register gegen das offizielle Handbuch geprüft: - switch_on/off: Reg 56 (Smart-Grid-Modus), analog zu Air2Airs Reg 1000 - set_power_limit: Reg 58 (Allgemeine Leistungsbegrenzung, gilt laut Handbuch unabhängig vom Smart-Grid-Modus, anders als Reg 57) - update: Input-Reg 51 (Stromverbrauch Wärmepumpe) - Altherma kann im Gegensatz zu Air2Air tatsächlich Leistung melden, daher METER_ONLY hier sinnvoll * Consumer: Add Mitsubishi and Gree AC modules (#3973) * Add Mitsubishi and Gree AC consumer modules * Mitsubishi/Gree: METER_ONLY entfernt, da keine Leistungsmessung Beide Module haben keine update()-Funktion und liefern somit keine Leistungsmessung; ConsumerUsage.METER_ONLY war daher nicht zutreffend. * Gree: tcid im Bind-Request ergänzt (Review Lena) cid muss beim Binden konstant "app" sein, tcid identifiziert das Zielgerät per MAC - bestätigt gegen tomikaa87/gree-remote und cmroche/greeclimate. * build UI (#4010) * Fixed Hours Tariff: migrate fixed-hours weekdays to Python weekday format (#4009) * Hierarchie: Entferne mit Verbraucher verknüpften Zähler (#4011) * Hierarchie: Entferne mit Verbraucher verknüpften Zähler * flake8 * Speicher-Vorrang bei Erholung von Mindest- bis Maximal-SoC (#3986) * bat_all: restore Speicher-Vorrang beim Erholen von Mindest-SoC bis Maximal-SoC * bat_all: Speicherleistung nicht ans Fahrzeug weitergeben, wenn Entladung nicht erlaubt ist * build UI (#4025) * Add ACLs consumer and load management topics (#3964) * Add acls * Add load management prio to status * fix colors theme: leftover pv_charging topic paths from PR #3812 topic migration (#3946) * Build Themes * Consumer: Add Kermi, LG Therma V, Luxtronik (#3971) * Add Kermi, LG Therma V and Luxtronik consumer modules * kermi, luxtronik: Skalierungsfaktoren korrigiert (Review #3971) Kermi Reg 301 (PV-Überschuss): war /10, muss *10 sein. Luxtronik Reg 10301 (el. Leistung): war *10, muss *100 sein. Reg 108 (Kermi) war bereits korrekt. * Sonnenbatterie: add OperationMode Optimization (#3769) * add Mode Optimization * check for valid OperatingMode * Fix load management single phase netting and Bidi discharge currents (#4012) * Lastmanagement: eigenen Ladestrom bei ein-/zweiphasigem Laden nicht mehr als Fremdlast zählen _set_current_left() entschied per min(element_current) < 0, ob der Strom eines Ladepunkts als Verbrauch oder Einspeisung zählt. Bei ein-/zweiphasigem Laden reicht dafür schon minimales negatives Messrauschen auf einer ungenutzten Phase - der eigene Ladestrom wurde dann nirgends vom Zähler-Rohwert abgezogen, das Lastmanagement hielt die eigene Ladung für Fremdlast (falsche "Maximalstromstärke erreicht"/Schieflast-Meldungen, siehe Discussion #3908). _set_power_left() hat exakt dasselbe Problem nicht, da dort schon die Gesamtleistung statt einzelner Phasenströme geprüft wird - jetzt angeglichen. * Bidi-Entladung: eigene Hardware-Stromgrenze des Ladepunkts durchsetzen check_min_max_current() rief check_cp_max_current() (setzt dc_max_current des Ladepunkt-Templates durch) nur im Lade-Zweig auf, nicht beim Entladen (BIDI_CHARGING, required_current < 0) - die vom Fahrzeug gemeldete max_discharge_power wurde beachtet, die eigene Hardwaregrenze des Ladepunkts nicht. Bug in #3795, check_cp_max_current() behandelt negative Werte bereits korrekt (Vorzeichen wird erhalten). * build UI (#4026) * Improve Monthly/Yearly Log (#3829) * Improve Log * Move generate_totals-Logger in logger.py * Fix * Fix Circular Import * Update .gitignore * fix * Ensure ramdisk folder exists * retrigger Copilot * Add Copilot suggestions * fix * Fix Tesla/Powerwall data handling and improve robustness of control loop (#3232) * tesla/powerwall: implement load management, add fail-fast handling and gateway diagnostics - add structured HTTP error handling in PowerwallHttpClient - distinguish transport, HTTP and JSON parsing failures - support fail_fast=False for non-critical requests - track cycle_failed and cookie_renewed state across one polling cycle - add fail-fast handling in device.py - stop remaining Tesla component updates once a critical Powerwall request fails - log native TCP connection state diagnostics via /proc/net/tcp(/tcp6) - emit periodic session / connection health logs - keep cookie reuse, but mark startup + reauth cycles explicitly - reduce /api/status traffic in counter.py - fetch firmware only after startup or after a new auth cookie was negotiated - treat /api/status as non-critical so it cannot fail the whole cycle - keep import/export counters based on aggregate["site"]["energy_imported/exported"] - do not use summed per-phase energy counters as meter source - keep /api/meters/site for phase details only - add derived fallback currents and signed power factors from P/Q/U when Tesla/Neurio currents are 0 - expose additional diagnostics such as frequency / serial number - add throttled debug logging to compare aggregate counters with per-phase sums - restore aggregate-based site counters so load management works correctly again * tesla/powerwall: simplify device/http client and keep cookie reauth handling - remove session / connection diagnostics and analysis-only helpers - remove /proc-based connection stats and periodic session logging - keep fail-fast handling for the Tesla update cycle - keep cookie reuse and 401/403 reauthentication flow - keep support for non-critical requests via fail_fast=False - reduce implementation closer to upstream while preserving Powerwall-specific fixes * tesla/powerwall: simplify device/http client and keep local current fallback - remove analysis-only diagnostics and session tracking from device.py - remove connection stats and other debug-only helpers - simplify http_client.py to a minimal request wrapper - keep cookie reuse and 401/403 reauthentication flow in device.py - use fail-fast handling in device.py via SingleComponentUpdateContext(..., reraise=True) - move Tesla-specific robustness back into the counter module only - keep aggregate["site"]["energy_imported/exported"] as sole source for EVU counters - keep local current and power factor calculation when Neurio/Tesla returns only 0 currents - remove /api/status handling from counter.py - fix formatting / lint issues (newline at EOF, spaces instead of tabs) * Fix Tesla error handling and compatibility note - use central openWB component error handling - remove Tesla-specific fail-fast handling - rely on the shared HTTP response hook - remove obsolete local API compatibility warning * se standard error handling in Tesla counter - remove _safe_float and module-specific defaults - propagate HTTP errors to central error handling - keep compatibility fallback for missing phase data - calculate phase currents from P/Q/U when Tesla reports zero currents * Fix Tesla module lint errors * Adjust Tesla API compatibility note * Error status table (#3943) * add error and warning icons to chargepoint table * Align warning icons - remove extra warning column * No tooltip for mobile - ellipsis title only if truncated * Build Themes * add consumer temperature readings to consumer card (#3974) * add consumer temperature readings to consumer card * check if temperature data is present * use getValueObject for formatting * Build Themes * Consumer: Add M-TEC, Weishaupt, Xtherma (#3972) * Add M-TEC, Weishaupt and Xtherma consumer modules * M-TEC: Reg 707 durch evcc-Quelle bestätigt, Kommentar aktualisiert Reg 707 (elektrische Leistungsaufnahme) ist in evcc's mtec.yaml als holding register mit scale 1 gelistet, identisch zu unserer Implementierung. * Weishaupt: Reg 33126 entfernt (nicht verifizierbar), Xtherma: SG-Ready on/off ergänzt Weishaupt: Reg 33126 (el. Leistungsaufnahme) ist weder in der offiziellen Datenpunktliste (83807301) noch in einer ausgereiften Community-Implementierung (OStrama/weishaupt_modbus) zu finden - update()/METER_ONLY entfernt, SollwertPV (Reg 40002, offiziell dokumentiert) bleibt unverändert. Xtherma: Reg 60 (SG-Ready-Modus) ergänzt switch_on/switch_off (SUSPENDABLE_ONOFF), eigener 30min-Throttle laut Protokoll. * Fix charge cost calc (#4022) * fix chargelog energy source calculation * Add Test * fix circular error --------- Co-authored-by: LKuemmel <76958050+LKuemmel@users.noreply.github.com> Co-authored-by: Copilot Autofix powered by AI <175728472+Copilot@users.noreply.github.com> Co-authored-by: SeaSpotter <florian.horch@gmail.com> Co-authored-by: ndrsnhs <156670705+ndrsnhs@users.noreply.github.com> Co-authored-by: s0170071 <33855380+s0170071@users.noreply.github.com> Co-authored-by: GitHub Actions <actions@github.com> Co-authored-by: BrettS <168732306+Brett-S-OWB@users.noreply.github.com> Co-authored-by: NicoP-codeing <nico.prenzel@pn-systeme.de>
…llen Powerwall 3 / Gateway 3 stellen /api/meters/site nicht mehr bereit und antworten mit HTTP 404. Bis einschließlich 2.2.3 hat der Zähler bei dieser Abfrage HTTPError abgefangen und auf die Gesamtwerte aus /api/meters/aggregates zurückgegriffen. Beim Umbau in openWB#3232 ist HTTPError aus der except-Klausel entfallen. Der 404, den der raise_for_status()-Hook der Session auslöst, setzt dadurch die gesamte Zähler-Komponente auf Fehler, obwohl Leistung, Bezug und Einspeisung in aggregates verfügbar sind. Ein 404 auf /api/meters/site wird jetzt als "Endpunkt nicht vorhanden" behandelt: Es werden die Gesamtwerte aus aggregates verwendet, und der Endpunkt wird für die Lebensdauer der Komponente nicht erneut abgefragt. Andere HTTP-Fehler (z. B. 500 oder 401/403, die device.py für die erneute Anmeldung nutzt) werden weiterhin ausgelöst.
…llen Eine Powerwall 3 mit Backup Gateway 2 stellt /api/meters/site nicht mehr bereit und antwortet mit HTTP 404. Bis einschließlich 2.2.3 hat der Zähler bei dieser Abfrage HTTPError abgefangen und auf die Gesamtwerte aus /api/meters/aggregates zurückgegriffen. Beim Umbau in openWB#3232 ist HTTPError aus der except-Klausel entfallen. Der 404, den der raise_for_status()-Hook der Session auslöst, setzt dadurch die gesamte Zähler-Komponente auf Fehler, obwohl Leistung, Bezug und Einspeisung in aggregates verfügbar sind. Ein 404 auf /api/meters/site wird jetzt als "Endpunkt nicht vorhanden" behandelt: Es werden die Gesamtwerte aus aggregates verwendet, und der Endpunkt wird für die Lebensdauer der Komponente nicht erneut abgefragt. Andere HTTP-Fehler (z. B. 500 oder 401/403, die device.py für die erneute Anmeldung nutzt) werden weiterhin ausgelöst.
…llen (#4105) Eine Powerwall 3 mit Backup Gateway 2 stellt /api/meters/site nicht mehr bereit und antwortet mit HTTP 404. Bis einschließlich 2.2.3 hat der Zähler bei dieser Abfrage HTTPError abgefangen und auf die Gesamtwerte aus /api/meters/aggregates zurückgegriffen. Beim Umbau in #3232 ist HTTPError aus der except-Klausel entfallen. Der 404, den der raise_for_status()-Hook der Session auslöst, setzt dadurch die gesamte Zähler-Komponente auf Fehler, obwohl Leistung, Bezug und Einspeisung in aggregates verfügbar sind. Ein 404 auf /api/meters/site wird jetzt als "Endpunkt nicht vorhanden" behandelt: Es werden die Gesamtwerte aus aggregates verwendet, und der Endpunkt wird für die Lebensdauer der Komponente nicht erneut abgefragt. Andere HTTP-Fehler (z. B. 500 oder 401/403, die device.py für die erneute Anmeldung nutzt) werden weiterhin ausgelöst. Co-authored-by: matmoers <ploetman@gmx.de>
see also OpenWB Forum entry: https://forum.openwb.de/viewtopic.php?t=11634
Problem
Tesla/Powerwall sometimes provides unusable or inconsistent per-phase energy values.
/api/status is not critical for the control loop, but currently can still affect it.
Missing current values from Tesla/Neurio result in incomplete data, causing load management to fail.
Critical HTTP errors currently do not stop the Tesla cycle, which can lead to cascading issues.
Changes
Restored aggregate-based import/export counters (site-level data)
Per-phase energy is now used for diagnostic purposes only
Reduced /api/status usage and marked it as non-critical
Added fallback calculation for currents and power factor from P/Q/U
Implemented fail-fast behavior for critical requests
Added additional diagnostics and session logging
Motivation / Background
The main goal of this change is to restore reliable load management by using per-phase values for current-related calculations and diagnostics while keeping consistent aggregate site import/export counters.
Additional improvements were made to increase robustness and observability of the Tesla/Powerwall integration, especially in cases of incomplete data or intermittent API issues.
Testing
Tested with a real Tesla Powerwall setup
Verified that load management works reliably again
Checked that import/export counters are consistent and plausible
Simulated missing current values → fallback calculation works
Simulated API timeouts → control loop continues without cascading failures