Skip to content

[a11y][Chip] Clickable always assigned to component #49511

Open

Description

@ayl01rwt

Steps to reproduce

Steps:

  1. Open this link to live example
  2. When table is displayed with Chip component within cell
  3. And user uses NVDA tool to navigate within table
  4. And user uses arrow keys to hover over table cell with Chip component
  5. Then NVDA states that Chip is clickable
Image

Current behavior

Chip component is labelled as clickable in NVDA

Expected behavior

Default clickable flag false

Context

NVDA screen reader displays Chip component within table cell to be clickable when it shouldn't

Your environment

npx @mui/envinfo
  Chrome 155.0.8059.85 
  Latest MUI

Search keywords: Chip

Activity

  1. A-Raphie commented on Oct 20, 2026

    @A-Raphie

    Could you paste the rendered outerHTML of the non-clickable Chip from the sandbox (the root element is enough)? In the current master a Chip without onClick/onDelete/clickable resolves clickable to undefined and renders a plain div root - no role="button", no tabIndex, and the clickable class (the one that adds cursor: pointer) is not applied. NVDA announces "clickable" from either a button-like role or pointer-cursor styling, so the exact rendered markup + which MUI version/v8-beta the sandbox resolves would pin down where the clickable semantics leak in (app wrapper vs the component).

  2. ZeeshanTamboli commented on Oct 21, 2026

    @ZeeshanTamboli
    Member

    I am not able to reproduce this issue using NVDA. It does not announce with the word "clickable" to me. Which version of NVDA are you using? I am using version 2026.2.0.57664. Maybe you need to upgrade your NVDA version.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment