A Custom (or edited) tower could have tiers below the firmware's minimum extrusion temperature with no warning; Klipper then stops the print (RPT-003).

ADR-0014: fixed limit COLD_EXTRUSION_MIN_TEMPERATURE = 175 °C, the highest stock default found (Prusa MK3S firmware 3.14.1: 175; Klipper, Marlin 2.1.2.5 and Buddy MK4: 170). Validation emits temperature-below-cold-extrusion-limit (download stays reachable), the config form shows the same warning, and a fixture triggers it.

Closes TSK-010.