tierCount floors |end - start| / step, so 230→228 step 5 gave a single tier and 230→190 step 15 never printed 190 °C, while the form and STL name said it would (RPT-004).

ADR-0013: the end temperature is the top tier and is reached exactly. validateTowerConfig rejects fewer than 2 tiers and a non-dividing step, naming the nearest reachable end temperatures. The config form lists the same problems. All presets stay valid (test added).