16 changes: 11 additions & 5 deletions terraform/contabo/vps.tf
Original file line number Diff line number Diff line change
Expand Up @@ -24,11 +24,16 @@ resource "contabo_instance" "prod" {
# the Cloudflare Named Tunnel (outbound-only from cloudflared).
# 8472/udp = Flannel VXLAN overlay — required for cross-node pod networking
# once worker nodes join (the server must accept inbound VXLAN from agents, or
# worker pods can't reach control-plane services). kubelet (10250) is NOT
# opened: k3s tunnels agent kubelets over the outbound 6443 connection, so no
# inbound 10250 is needed and exposing it would be an unnecessary risk.
# 8472 Anywhere here is a rebuild bootstrap default; the live runtime rule is
# scoped to node IPs (durable fix: wireguard-native overlay / private VLAN).
# worker pods can't reach control-plane services).
# 10250/tcp = kubelet read-only/authenticated API. It IS needed inbound:
# metrics-server runs OFF the control-plane (on a worker) and dials each
# kubelet directly at <node-ip>:10250 — it does NOT ride k3s's 6443 tunnel
# (that tunnel only backs apiserver→kubelet proxying for logs/exec, not the
# metrics scrape). Without this rule, `kubectl top node vmi3383846` returns
# <unknown> and HPA/scheduling signals for this node go dark (issue #318).
# 8472 and 10250 Anywhere here are rebuild bootstrap defaults; the live runtime
# rules are scoped to node IPs (durable fix: wireguard-native overlay / private
# VLAN). See ufw allows below.
# 51820/udp = Flannel WireGuard-native overlay (see provisioning.tf for the
# --flannel-backend=wireguard-native install flag). Opened ALONGSIDE 8472/udp
# during the transition: the flag is inert on the already-running prod
Expand All @@ -39,6 +44,7 @@ resource "contabo_instance" "prod" {
- ufw allow 22/tcp
- ufw allow 6443/tcp
- ufw allow 8472/udp
- ufw allow 10250/tcp
- ufw allow 51820/udp
- ufw --force enable
EOT
Expand Down