Reads measurements straight off an Omron cuff into Home Assistant, over BLE, with no Omron cloud account and no phone involved. The cuff keeps its readings in an internal memory; this component opens a session, copies what is there, and publishes it.

248 model names across 37 profiles. One profile has been verified against real hardware. Read Confidence levels before trusting a reading from any of the others.

Quick start

external_components:
  - source: github://dzikus/esphome-omron

esp32_ble_tracker:

omron:
  - id: omron_cuff
    mac_address: !secret omron_mac
    profile: auto          # see "Which profile is mine" below
    # Everything that varies per person lives here, so a platform block below
    # only has to say which user it is for.
    users:
      - user: 1
        name_prefix: Alex

# One block per person, plus one for the cuff itself. Each block creates the
# whole set of entities it is entitled to; there is nothing to list by hand.
sensor:
  - platform: omron
    omron_id: omron_cuff          # the cuff's own: clock drift, poll duration, RSSI
  - platform: omron
    omron_id: omron_cuff
    user: 1                       # this person's readings

text_sensor:
  - platform: omron
    omron_id: omron_cuff
  - platform: omron
    omron_id: omron_cuff
    user: 1

A fuller node is in example.yaml.

Flash it, then press the cuff's Bluetooth button briefly. The node connects, reads, publishes and disconnects. A session takes five to seven seconds.

A block without user: carries the cuff's own entities (clock, status, RSSI); a block with user: N carries one person's measurements. Configure only the first kind and every record is read correctly and has nowhere to go. The component says so at startup rather than leaving you to notice.

Which profile is mine

Omron sells one cuff under several model codes and several cuffs under one trade name, and the code on the box is not always the one that matters: HEM-7155T alone covers four different memory layouts. Picking the wrong profile does not fail. It reads a different region and publishes numbers that look like blood pressure.

So do not guess. Set profile: auto, press the button once, and read the log:

[W] Detected HEM-7155T-MW3 from "X4 Smart" (trade name), hardware verified.
    Pin it with `profile: hem_7155t_mw3` in the yaml.

Then put that line in the yaml and leave it there. auto is for finding the answer, not for running on: under it ESPHome cannot validate the user count or the bind key requirement at config time, because neither is known until the cuff has been asked.

If detection cannot decide, it says so and refuses rather than guessing. Two trade names are genuinely ambiguous, and a cuff whose reported string means nothing here is the expected case for models nobody has tried.

With a profile configured, the same check runs as a verification: it confirms the profile, accepts a different entry over the same memory map, or reports a mismatch. Loudly, and once per session, because a wrong map is the one failure nothing downstream can catch.

First run and pairing

Most Omron cuffs need to know this node before they will keep talking to it, and they drop the bond of a host that pairs without registering. The component handles that, but the button sequence is yours to press:

  1. Hold the cuff's Bluetooth button until -P- blinks. The cuff is now offering pairing.
  2. The node bonds, registers itself, and reads. One session.
  3. From then on a brief press is enough.

Two options govern this, and neither belongs in a working config: both take their answer from the profile, which is why the example writes neither.

  • require_bond bonds before touching any characteristic. Cuffs on the newer stack refuse everything else, and their profiles say so.
  • keep_bond lets the bond survive the session. No profile here asks for it to be dropped: a cuff that looks like it invalidates its side after every session is really discarding the bond of a host that never registered itself. Setting it to false means pairing mode every single time.

If a bond ever goes stale, the Forget bond button drops this node's own record and only that one; the next pairing starts clean. Watch for Selective bond cleanup complete before holding the button again.

Cuffs that store a key instead

Older models do not rely on the Bluetooth bond at all. They keep a 16-byte key in their own memory, and a host proves itself by presenting it. Roughly half the profiles here work this way; the component says so at startup and refuses to guess, so the sign of one is requires an already-provisioned bindkey in the log.

The key is yours to invent. It is not issued by Omron and there is nothing to look up: pick 32 hex characters, put them in bindkey, and the node writes them into the cuff the first time it pairs. What matters is that the value never changes afterwards, because the cuff stores it and every later session authenticates with it. It is not tied to this node either - the same key from a different node, with a different Bluetooth address, still works.

ESPHome treats the option as sensitive and masks it, so keep it in !secret like the MAC.

omron:
  profile: hem_7155t
  bindkey: !secret omron_bindkey   # 32 hex characters, yours to choose

Programming only happens while the cuff is showing -P-, so the first run needs the long press exactly as above. If a key is refused, power the cuff off before trying again: it latches the error and will reject even a correct key until it is restarted and put back into pairing mode.

Coming from another tool, the cuff already holds a key and you have to match it. Both omblepy and the Home Assistant omron integration write the same fixed value, so a cuff paired with either wants:

  bindkey: deadbeaf12341234deadbeaf12341234

Anything else is refused, since the cuff compares against what it stored. Pairing again with a key of your own replaces it - and then the other tool stops working until it is told the new one.

None of this path has been run against hardware here - no cuff of that kind was available - though it is checked frame by frame against implementations that have. Treat a first pairing as something to watch the log through.

What it publishes

Per user: systolic, diastolic, pulse, pulse pressure, estimated MAP, shock index, rate pressure product, ACC/AHA category, measurement timestamp, sequence number, and the detection flags the model actually supports: cuff fit, body movement, irregular pulse, and where the model has them, consecutive-measurement, artifact and IHB counts. Also what the cuff stores about that person rather than measures: their birth date, and on models that keep one, the settings version counter that says whether a registration landed. Per cuff: device clock and its drift, model, firmware, serial, poll duration, link state, RSSI, and a battery-low flag whose meaning is unproven - see the note on it in the source.

Older readings still in the cuff's ring are emitted as esphome.omron_measurement events with their original timestamps, watermarked in flash so each is sent once.

Platforms: sensor, binary_sensor, text_sensor, button, switch.

Configuration

On the omron: block:

option meaning
mac_address required, the cuff
profile required, a profile name or auto
bindkey 32 hex characters you choose, for profiles that store a key rather than bond; see above
time_id a time source, used to report clock drift and to set the cuff's clock
history_records how deep to read; omit for the whole ring, 0 for the newest only
ignore_records_before drop readings older than this date
require_bond, keep_bond see above
register_as_user which user slot this node registers as when pairing
clock_sync_threshold drift tolerated before the clock is rewritten; 0s means every session
auto_connect connect on a readable advertisement rather than waiting for the button
full_read_on_pairing re-read every ring when the cuff advertises pairing, default off
device_id sub-device for the cuff's own entities
users one entry per person, see below

Everything that varies per person goes in one entry under users:, so a platform block only has to say which user it is for:

omron:
  - id: omron_cuff
    mac_address: !secret omron_mac
    profile: auto
    register_as_user: 2
    device_id: cuff_device
    users:
      - user: 1
        device_id: user1_device
        name_prefix: Alex
        birth_date: 1955-11-05
        # Needed only for someone this node does not register as.
        write_birth_date: true
      - user: 2
        device_id: user2_device
        name_prefix: Sam

sensor:
  - platform: omron
    omron_id: omron_cuff
    user: 1
per-user option meaning
device_id sub-device this person's entities file under
name_prefix prefix for their entity names, defaulting to the sub-device's name
birth_date written into their settings block, and read back to confirm it landed
write_birth_date send the date without registering as them

The prefix is not cosmetic. Two people would otherwise both get an entity called "Systolic blood pressure", and an entity's API key is a hash of its name with no device in it, so they collapse into one on MQTT and on any client that addresses by key. Without a prefix or a sub-device name to borrow, it falls back to "User 1" and "User 2".

Confidence levels

Every profile states how much is actually known about it, and the node says so at startup:

level count what it means
hardware verified 1 read off a real cuff of that model
reference tested 9 another project reports the model as working
transcribed from a catalog 28 the map has not been confirmed on that device by anyone in the chain

The last group is the majority, and those profiles log a warning every boot for that reason. If your model is in that group, compare the first few readings against the cuff's own screen. A map that is internally consistent is not the same as a map that is right.

What this does not do

  • No backfill into Home Assistant history. New measurements arrive seconds after the cuff finishes; older ones are emitted as events with their real timestamps, and what happens to them is up to you. HA does not accept historical states, only hourly statistics buckets, which would merge a TruRead series into one point.
  • No live readings during a measurement. The standard blood pressure characteristic is subscribed only while the model is unknown, where it is the whole of what a session can offer. With a profile the memory read is the source, and nothing else that talks to these cuffs subscribes that characteristic alongside one either.
  • No guessing. An unrecognised model gets no profile, and a cuff whose memory map cannot be resolved gets a live-only session rather than an invented map.
  • No writes you did not ask for, but not none either. Three things go into the cuff's memory: the clock, once per session; the "not yet collected" marker of every person whose readings were just taken, which is how the cuff is told they arrived; and, only in a session that pairs, that user's settings block. Nothing else is written, and no measurement is ever altered.

Requirements

ESP32 with esp32_ble_tracker. The component runs its own GATT client and takes one connection slot. Bonding on ESP32 with these cuffs is delicate and the sequencing here took a long time to get right; if you are sharing the node with other BLE clients, raise esp32_ble.max_connections accordingly.

Development

bash tests/run_protocol_tests.sh builds the host test suite the way the firmware is built (gnu++20, -Wall -Wextra -Werror) and runs it. It ends with ok: N test groups passed; anything else, including a silent exit, is a failure.

Set OMRON_TEST_LOG=1 to see the component's own log lines while the suite runs. They are the lines the device prints, and they are off by default so that a run shows its assertions and nothing else.

python -m unittest discover -s tests/python runs the code generation and table tests; it needs esphome installed.

New functionality comes with tests in the same pull request: protocol, session and publishing logic in tests/, code generation and the tables in tests/python/.

Issues and pull requests

Report problems at https://github.com/dzikus/esphome-omron/issues. For a cuff that is not recognised or is read wrong, use the Cuff report form. Include the component version or commit, the ESPHome version, the cuff model and profile, the configuration and the node log, with the MAC address and the bindkey removed. Report security issues privately, see SECURITY.md.

Pull requests go against main:

  • Run pre-commit install once. The hooks format C++ and Python and check that commit messages follow Conventional Commits.
  • A pull request that adds functionality adds tests for it, see Development.
  • CI runs pre-commit, the unit tests, clang-tidy and the ESP32 builds on every pull request. All of them must pass before merge.
  • User-visible changes get an entry in CHANGELOG.md.

License

GPL-3.0. See LICENSE.

About

ESPHome component for Omron Bluetooth blood pressure monitors

Topics

Resources

Security policy

Stars

4 stars

Watchers

1 watching

Forks

Releases

Used by

Contributors

Languages