Repository navigation
transformers
The ideal transformer for e-stim applications has these specifications:
- Isolation rating of
$1500V$ or better. - Flat frequency response and low phase shift for frequencies
$500Hz$ to$3000Hz$ . - Low-ish DC resistance around
$1 \Omega$ for the driving side. - A winding ratio between
$1:5$ and$1:15$ , the ideal ratio depends on drive circuit characteristics. - Saturation between
$5,000V\mu s$ and$40,000V\mu s$ . Higher values are dangerous.
Annoyingly, some of these specifications are rarely mentioned in the datasheets.
The winding ratio is the square root of the impedance ratio.
A simple test to figure out the winding ratio and saturation for your specific transformer.
Requires an oscilloscope and a few basic components, a voltage source, capacitor and pushbutton.
The idea is to generate a square waveform (here from 0 to 5V) with the pushbutton, measure the voltage response on both sides. The input is the low-voltage side, and the output the high-voltage side.


The winding ratio is the voltage ratio at the start of the pulse
(about
The saturation is the area under the yellow curve, about
The saturation (volt-seconds) can be estimated from the inductance and saturation current. Recall the basic RL-circuit squation.
The transformer reaches saturation at time:
We want to know
If we select
The inductance scales with the
Many readily-available transformers are created for switch-mode power supplies.
These operate at a voltage of
With 50% duty cycle, it follows that volt-seconds is
- Xicon transformers. The only suitable option.
- elma TT IZ1892. A large audio transformer, commonly used in stereostim devices.
Assortment of 230v transformers: