@hemertje

Summary

After the Zaptec account email address was changed, the integration kept its config entry loaded for about two weeks with 23 of 25 sensors unavailable. No warning at default log level, no reauth, no Repair, no persistent notification. The cause only became visible with DEBUG logging.

What happened

  • Login (/oauth/token) still returned 200 with the old username, so ConfigEntryAuthFailed was never raised.
  • /api/installation and /api/chargers then returned 200 with a 36-byte body (an empty list), so the hierarchy contained zero chargers.
  • first_time_setup produced zero tracked devices and logged "Zaptec setup complete".
  • The Zaptec app (logged in with the new address) showed the charger and all sessions normally, so the charger and the cloud were fine.
  • A reload of the entry and a charger firmware update changed nothing.
  • Reconfiguring the entry to the new address fails with unique_id_mismatch (the entry's unique id is the old username), so the entry had to be deleted and added again.

Debug log (default level shows nothing)

[custom_components.zaptec.zaptec.api] @@@ REQUEST POST to 'https://api.zaptec.com/oauth/token'
[custom_components.zaptec.zaptec.api] @@@ RESPONSE 200 length 1424
[custom_components.zaptec.zaptec.api]      TOKEN OK
[custom_components.zaptec.zaptec.api] Discover and build hierarchy
[custom_components.zaptec.zaptec.api] @@@ REQUEST GET to 'https://api.zaptec.com/api/constants'
[custom_components.zaptec.zaptec.api] @@@ RESPONSE 200 length 37969
[custom_components.zaptec.zaptec.api] @@@ REQUEST GET to 'https://api.zaptec.com/api/installation'
[custom_components.zaptec.zaptec.api] @@@ RESPONSE 200 length 36
[custom_components.zaptec.zaptec.api] @@@ REQUEST GET to 'https://api.zaptec.com/api/chargers'
[custom_components.zaptec.zaptec.api] @@@ RESPONSE 200 length 36
[custom_components.zaptec] Zaptec setup complete

Suggestion

After discovery, if the hierarchy contains no chargers, log a warning and raise a Repair (or fail the setup with ConfigEntryError), so the user is told that the account is valid but sees no installation or charger. Optionally also make the config entry's unique_id independent of the username, or allow reconfiguring the username.

Environment

  • Integration version 0.8.7
  • Home Assistant Core 2026.10.0
  • Zaptec Go, firmware 2.6.1.6

Activity

  1. steinmn commented on Oct 17, 2026

    @steinmn
    Contributor

    Should already be handled by #415, which will be included in 0.8.8

  2. rhammen commented on Nov 1, 2026

    @rhammen
    Contributor

    I don't think #415 covers this: it only relaxed the validation models, and an empty installation/charger list already passed validation, so setup still completes silently with nothing tracked.

    #450 makes setup fail in this case, with an error on the integration card naming the account username (the username is kept out of the log).

    The second part (unique_id tied to the username, so reconfiguring to a new email fails) isn't addressed there and would need a separate change.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions