@mcalisterkm

I am on a 64bit linux platform with hardware floating point and getting -ve values for both pressure and humidity, from a BME688 sensor.
I thought this was an unsigned to signed conversion error but it is not, this value is calculated and inside calc_humidity()
The hum_adc value is around 23232 and hoff is -27008 and the float cast returns -4.065e-19.
I have yet to debug pressure but I am getting the same -ve values.