@jayrmotta

I've noticed the fan behavior of my Bitaxe change (on/off by default) almost randomly when I power it up. It happens both when I start it normally or in boot mode.

I'm often on edge because I'm afraid the firmware isn't holding the ASIC on reset and might be generating heat without the fan to help cool it off. Once it actually got really hot and I thought it was idle, luckily no apparent damage happened.

More recently in this 256foundation/mujina#33 (comment) we aren't sure how safe it would be to rely on a fan default behavior, curious to hear if that's a common observation among others as well.

Activity

  1. rkuester commented on Mar 31, 2026

    @rkuester
    Contributor

    100% agree the fan does not reliably start at power-up. I have seen this on all of my three Bitaxe Gamma 601's here. Whether the ASIC is held in reset is a thermally-related but separate issue. Here's what I know about both:

    Fan

    At least through (1fc7d60), the bitaxe-raw firmware is making no attempt to initialize the fan, so we're relying on the hardware default. According to the EM2101 fan controller datasheet section 4.2, the fan should turn full-on at startup due to the R24 5.6k pull-up.

    This appears to be unreliable, however. @skot and I have talked about this quite a bit, but to no avail. (I'm kinda surprised I never filed a bug over in bitaxeorg/bitaxeGamma against the hardware, but I don't see one.)

    An interesting wrinkle: this initial setting only applies if the part is the EMC2101-R variant, and not its close cousin the EMC2101 variant. The Bill of Materials indeed calls for an EMC2101-R. Of the three Bitaxe Gamma 601s I have, only one of them1 has what purports to be the EMC2101-R variant. However, even the unit with the EMC2101-R suffers intermittency. 🤷‍♂️

    There is a product ID readable via I2C with identifies which variant the part is, and I've just added logging to Mujina in 256foundation/mujina@46db975 which prints it out at debug level. The numbers on the packages are slightly different too2.

    Reset

    I made sure reset was held low coming out of power-up way back in 025901d, after anonymizing a fingerprint by touching the heatsink in just such a case. Surprisingly, with reset low the ASIC still seems to draw about 2 W. That's enough power to make a fanless 40mm heat sink uncomfortable (60-degC/140-degF?).

    Conclusion

    In hardware, the regulator powering the ASIC turns on by itself, and this bitaxe-raw firmware does nothing to stop it. The firmware probably should turn it off to mitigate this issue. The fan turning on by itself is a nice to have, but the hardware probably shouldn't draw real power until software wants it to.

    Footnotes

    1. For what it's worth, all three came from PlebSource in early 2025, perhaps ordered a couple months apart. My guess is they're not the only Bitaxe manufacturer that might inadvertently substitute the wrong part here, not realizing there is a difference. ↩

    2. Image Image ↩

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions