Skip to content

Requirement file, Revit IDS, model-check screen docs (v0.44–v0.53) + model health checks - #81

Merged
SamuelAB merged 12 commits into
mainfrom
claude/project-thread-qhh2n0
Nov 23, 2026
Merged

SamuelAB merged 12 commits into
mainfrom
claude/project-thread-qhh2n0

Conversation

@SamuelAB

@SamuelAB SamuelAB commented Nov 23, 2026 •

Copy link
Copy Markdown
Owner

Requested by Sam · project thread

Brings Sam's work from the SamuelAB-VIM fork into main.

From sam/requirement-file (10 commits, taken as is)

  • v0.44: a requirement file export (JSON) and a Model rules section (16 kinds of rule)
  • v0.45–v0.47: wall kinds from the wall type's family and Function, fire ratings in minutes, STC/ASTC/IIC as whole numbers, a structural walls group
  • v0.49–v0.51: a second IDS export for Revit (Revit categories and parameter names only), concrete-only rows, checked Revit built-in names, Assembly Code must be a Uniformat II code
  • v0.52–v0.53: curtain wall parts counted but not scored, an empty lining or insulation counted as "none", rows with no Revit parameter shown as not checkable, a worksets rule
  • docs/model-check-screen/: design, pictures and example data for a VIM Flex check screen that reads the requirement file

From sam/03-checker-model-health (re-applied on top)

  • IFC check: storeys (duplicated by name or elevation, or empty), grid count, IfcBuildingElementProxy share
  • Schedule check: rows in Generic Models or Specialty Equipment, and categories the plan doesn't cover
  • 15 EN/FR/JA dictionary rows. Sam approved this on 2026-11-23 as an exception to the "no new model-checking features" rule.

Local checks: LOD, names and library checks, test_i18n.js, crawl_app.js, both reqfile_parity.js runs, check_i18n.py --app --strict, and a node test of the IFC model health on a small file. All pass.

🤖 Generated with Claude Code

https://claude.ai/code/session_01PYjDnDx9k182RtcuhtAu7c

SamuelAB-VIM and others added 10 commits November 20, 2026 12:11
The Builder can now write one machine-readable requirement file: every
element type with its Revit categories, the parameters asked at each
milestone, how a value is judged, and the plan's model rules. A new
Model rules section states 16 kinds of rule in the BEP draft. Nothing
is checked in OpenBEP; the existing model checker is unchanged.

A parity test shows that a reader of the file alone reproduces the
Builder's own check on the school example.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
Walls are told apart by what Revit itself records: the wall type's
family (basic, curtain, stacked), its Function (interior, core-shaft,
exterior, foundation, retaining) and, as a second question, the wall's
Structural Usage. Walls no element type covers (soffit, modelled in
place) are listed as not covered instead of being dropped.

The Builder's model check places walls by Function when the schedule
has that column; without it the result says walls could not be told
apart. The parity test now runs in the automatic checks.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
Fire resistance and fire protection ratings are now shared whole-number
parameters in minutes (0, 20, 30, 45, 60, 90, 120, 180, 240; 0 means no
rating required). STC, ASTC and IIC are whole numbers from 20 to 80.
Interior, exterior and curtain walls ask for a fire rating in every
project that authors a design model. Six optional parameters, off by
default, cover the joints at the head and base of a wall and the side
the fire comes from.

No parameter was deleted or renamed and no GUID changed; the built-in
Fire Rating text and the old text parameters stay available for tags.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
A wall whose Structural Usage is Bearing, Shear or Structural combined
keeps the requirements of its wall kind and must also meet a
structural group modelled on columns and slabs. The group shows on the
LOD page, in Element requirements, in the BEP draft and in the
requirement file. The Builder's model check applies it when the
schedule has a Structural Usage column.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
A second IDS export uses only Revit categories and Revit parameter
names, so a model can be checked against the plan without any IFC
concept. Structural walls are real specifications selected by
Structural Usage. The existing IFC IDS export is unchanged.

Structural walls are asked for a real material from LOD 200.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
Structural wall requirements are plain rows marked 'Structural walls
only'. Concrete cover, exposure class and reinforcement are asked only
of walls, columns and slabs whose structural material is concrete. The
IDS for Revit states as real requirements what a Revit parameter
holds, and no longer says 'check in the Revit model'.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
…ssembly Code format (v0.51)

The requirement file and the IDS for Revit use Revit's own built-in
names for U and R values, room finishes, beam end connections, ramp
slope and duct lining. Workset and Design Option can be asked of any
element type (optional, off by default). Load bearing on walls reads
Structural Usage. Assembly Code must be a Uniformat II code. A
requirement that names two Revit parameters is filled only when both
are.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
…rows (v0.52)

Only the curtain wall itself is scored against its requirements;
panels and mullions are counted as parts. A duct or pipe with no
lining or insulation is reported as none and not marked down. An
Assembly Code is case-sensitive everywhere. A requirement with no
certain Revit parameter is carried as not checkable instead of
scoring zero. Requirement file format 1.5.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
The rule counts the worksets the plan names that are missing from the
model's user worksets. Other user worksets are listed for information.
A new switch, off by default, forbids worksets the plan does not name.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
…Models)

Ported from Sam's branch sam/03-checker-model-health (SamuelAB-VIM fork) onto current main.
IFC check: storeys with duplicate names or elevations, empty storeys, grid count, IfcBuildingElementProxy share.
Schedule check: rows in Generic Models or Specialty Equipment, and categories the plan has no element type for.

Co-Authored-By: Samuel Arsenault-Brassard <Samuel.Arsenault-Brassard@vimaec.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01PYjDnDx9k182RtcuhtAu7c
@SamuelAB SamuelAB self-assigned this Nov 23, 2026
SamuelAB-VIM and others added 2 commits November 23, 2026 18:28
…tures, example data)

Reference for anyone building a checker screen on the OpenBEP requirement file:
the design of one screen (versions, rules over time, what changed), pictures, a demo
requirement file and two example results, and the known faults to fix.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
… health checks

Took sam/requirement-file from the SamuelAB-VIM fork as is, then re-applied the model
health additions on top: ifcHealth/ckHealthHtml, tblHealth on the reworked schedule check,
and the 15 dictionary rows. Rebuilt the I18N block and strings.js.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01PYjDnDx9k182RtcuhtAu7c
@SamuelAB SamuelAB changed the title Model checker: report model health (storeys, grids, proxies, Generic Models) Requirement file, Revit IDS, model-check screen docs (v0.44–v0.53) + model health checks Nov 23, 2026
@SamuelAB
SamuelAB merged commit 2e24d8d into main Nov 23, 2026
1 check passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.