Local, cloud-free integration for the Wavin Sentio central control unit (CCU-208) using Modbus TCP. Set up from the UI, no YAML needed.
This integration was written by an AI assistant (Claude, by Anthropic) in a conversation with the repository owner, who directed the work and tested it on his own installation. It was not written or reviewed by a professional developer or by Wavin.
- It may contain bugs and wrong assumptions. Register meanings come from Wavin's public Modbus manual, not from Wavin's source code.
- It has been tested on one real installation (see Tested setup) and otherwise only against a simulator. Your setup may behave differently.
- Parts of the Home Assistant side were never run in a CI environment. Expect rough edges.
- This integration can write to your heating controller (setpoints, modes, standby, vacation). Wrong values can affect comfort and energy use. Start with the controller in Read only mode if you are unsure.
- Provided "as is" under the MIT license, without any warranty. Do not rely on it for anything safety-critical (frost protection, flood prevention, and so on). Your controller's own safety functions keep working independently of Home Assistant.
- Unofficial. Not affiliated with, endorsed by, or supported by Wavin or Orbia. Do not contact Wavin support about problems with this integration.
Bug reports and pull requests are very welcome, see Contributing.
- Features
- Tested setup
- Requirements
- Enable Modbus TCP on the Sentio
- Installation
- Setup
- Devices and entities
- Using the integration
- Options
- Removing unused devices
- Reading raw registers (debug action)
- Troubleshooting
- Limitations
- Safety and security
- Contributing
- How it was built
- License
- Fully local over Modbus TCP (port 502). No Wavin account, no internet access needed.
- Devices are organised like your installation:
- one device for the controller (
Wavin Sentio CCU#xxxx), - one device per zone (named from the zone name stored in the Sentio),
- one device per heating circuit (HCC) that is in use,
- one device for the heat source (boiler / heat pump).
- one device for the controller (
- Zones, circuits and the heat source are discovered automatically. Unused ones are not created by default and can be switched on or off in the options.
- Climate entity per zone with current temperature, target temperature and Schedule/Manual mode.
- Thermistor inputs T1–T5, outdoor temperature, and a flow/return ΔT sensor.
- Pump state, flow temperature, boiler state and error flags.
- Reads are batched, "device busy" answers are retried, and invalid values show as unavailable instead of strange numbers.
- A debug action to read raw registers, useful for bug reports.
- English and Danish translations.
The author's installation, for reference:
- Sentio CCU-208, firmware TM60018.4, Modbus TCP set to Slave Read/write
- 8 zones (two zones share one room sensor, two zones unused), no floor sensors
- Gas boiler with a 3-way valve and a heat exchanger for the floor heating
- Floor heating circuit with its own pump on output P1 (seen by the integration as HCC1)
- Flow sensor on T2, return sensor on T3
- Home Assistant OS
Everything else in the Wavin manual (ITC controllers, domestic hot water, buffer tank, ventilation, dehumidifiers, cooling) is not tested and mostly not implemented, see Limitations.
- Sentio firmware TM60014 or newer (needed for Modbus TCP, according to Wavin's manual).
- Modbus TCP enabled on the controller, see below.
- The controller reachable on your network. Use a fixed IP (DHCP reservation in your router).
- Home Assistant 2025.3 or newer. This minimum is an estimate and has not been verified against older releases.
- Optional: HACS for installation and updates.
Modbus is off by default. On the Sentio display:
- Go to System → Installer settings → Modbus settings → Modbus TCP.
- Choose a mode:
- Read only: monitoring only. Writes from Home Assistant are rejected.
- Read/write: needed to change setpoints, modes, standby and vacation.
- Write with password is not supported by this integration (it never sends the password), so writes will fail in that mode.
- Note the controller's IP address (or reserve one in your router). The DHCP hostname is
Wavin Sentio CCU#followed by the last four digits of the serial number.
Newer Home Assistant versions are bringing HACS into core as a built-in Marketplace (reported as targeted for 2026.11). Custom GitHub repositories are reported to remain supported there, but menu names and steps may differ from what is written below. Check your version's documentation if you cannot find Custom repositories.
- In Home Assistant open HACS (or the Marketplace), then the menu (⋮) → Custom repositories.
- Add
https://github.com/puppetmaster91/Wavin-Sentio-Modbus-Localwith category Integration. - Find Wavin Sentio Local in HACS, install it, and restart Home Assistant.
- Download this repository.
- Copy the folder
custom_components/wavin_sentiointo/config/custom_components/on your Home Assistant (so you get/config/custom_components/wavin_sentio/). - Restart Home Assistant.
- Settings → Devices & services → Add integration, search for Wavin Sentio Local.
- Enter:
- IP address of the controller,
- Port:
502, - Modbus unit ID:
1(the manual also mentions255"if needed", so try that if1does not answer).
- The integration reads the controller's serial number, discovers zones and circuits, and
creates the devices. The title becomes
Wavin Sentio CCU#xxxx.
Only one entry per controller is allowed. If the IP address changes, adding the same controller again updates the stored address.
Entity IDs are built from the device name and entity name, so yours will differ from the examples. Entities marked diagnostic are hidden from the default dashboard cards; entities marked off by default are created disabled and can be enabled in the entity settings.
| Entity | Type | Notes |
|---|---|---|
| Standby | switch | Controller-wide standby. Writes the Standby register. |
| Vacation | switch | Controller-wide vacation mode. |
| Outdoor temperature | sensor | From the Sentio's outdoor input. |
| Heating/cooling mode | sensor | heating or cooling. |
| Thermistor input T1–T5 | sensor | Raw temperatures. Only inputs with a connected sensor are enabled by default. Rename them (for example T2 → "Flow"). |
| Flow/return difference | sensor | ΔT in K. Default is T2 minus T3. Choose other inputs in the options. |
| Warning / Error | binary sensor, diagnostic | Aggregated flags for the whole system. |
| Entity | Type | Notes |
|---|---|---|
| (zone name) | climate | See Climate. |
| Air temperature | sensor | Enabled by default only if the zone reports a value. |
| Humidity | sensor | Same. |
| Floor temperature | sensor | Same. Not created as enabled if you have no floor sensor. |
| Dew point | sensor, diagnostic | |
| Desired temperature | sensor, diagnostic, off by default | The controller's effective target. |
| State | sensor, diagnostic | idle, heating, cooling, blocked_heating, blocked_cooling. |
| Blocking source | sensor, diagnostic | Why the zone is blocked, for example contact, outdoor_temp, deadband. |
| Warning, Error, Low battery, Peripheral lost | binary sensor, diagnostic |
Zones that share a room sensor (two zones in one room, for example) each get their own device. A zone without its own sensor may have unavailable air temperature and humidity. If two zones have the same name, the zone number is added to the device name.
| Entity | Type | Notes |
|---|---|---|
| Pump | binary sensor (running) | Pump state as reported by the controller. |
| Pump demand | binary sensor, diagnostic | |
| Flow temperature | sensor | Measured flow temperature of the circuit. |
| Desired flow temperature | sensor | The controller's calculated target (heat curve). |
| Highest desired room temperature | sensor, diagnostic | Enabled only if reported. |
| State, Blocking source | sensor, diagnostic | |
| Warning, Error, Flow sensor failure, High temperature cut-off | binary sensor, diagnostic |
The Wavin manual has no registers for the physical pump outputs (P1/P2). Pump state is taken from the heating circuit the pump belongs to.
Created when the controller reports an H/C source or a boiler/heat pump.
| Entity | Type | Notes |
|---|---|---|
| State (H/C source) | sensor | |
| Boiler state | sensor | idle, heating_active, blocked_heating, failure and so on. |
| Requested boiler temperature | sensor | |
| Boiler inlet temperature | sensor | Enabled only if a sensor reports a value. |
| Blocking source | sensor, diagnostic | |
| Warning / Error / Failure flags | binary sensor, diagnostic | Flags the firmware does not provide show as unknown. |
Each zone has a climate entity.
- HVAC modes:
Heat= Manual mode on the Sentio,Auto= Schedule mode. - Current temperature: the zone's air temperature.
- Target temperature: the controller's effective desired temperature. It follows the schedule, vacation, standby or temporary override, so it can change by itself.
- Setting a temperature from Home Assistant writes the manual setpoint and switches the zone to Manual (Heat), because the Sentio ignores the manual setpoint in Schedule mode. Switch the zone back to Auto to return to the schedule.
- Step is 0.5 °C, range 5–35 °C. The controller may round or limit values to its own step and limits.
- Attributes:
manual_setpoint,override(none,temporary,vacation_away,adjust),blocking_sourceandzone. - The action is
heating/cooling/idlebased on the zone's state.
The two switches on the controller device turn the whole system's Standby or Vacation mode on and off.
automation:
- alias: "Wavin Sentio error"
triggers:
- trigger: state
entity_id: binary_sensor.wavin_sentio_ccu_1234_error # adjust to your entity
to: "on"
actions:
- action: notify.notify
data:
message: "The Wavin Sentio reports an error."Add the three sensors (T2 and T3, renamed, plus Flow/return difference) to an entities or history graph card.
Open the integration, then the gear icon (Configure).
| Option | Description |
|---|---|
| Zones to create | Choose which of the discovered zones become devices. |
| Heating circuits (HCC) to create | Shown only if circuits were discovered. |
| Flow / return thermistor for ΔT | Choose T1–T5, or - to disable the ΔT sensor. |
| Update interval | 5–300 seconds. Default 15. Each update makes roughly 30 Modbus requests with a typical setup. |
The integration reloads when you save. Discovery runs when the integration loads. If you connect a new zone or circuit later, reload the integration (⋮ → Reload) so it is found, then select it in the options.
By default a zone is created only if it reports a valid desired temperature, and a circuit only if it reports a valid flow temperature. That is how unused zones and circuits are kept out.
Devices for zones or circuits you have deselected can be deleted: open the device → ⋮ → Delete device. The controller device and all active devices are protected and cannot be deleted. If you only see Disable, the device is still selected in the options.
The action wavin_sentio.read_registers reads raw Modbus registers and returns them. It is
meant for debugging, for exploring a setup, and for bug reports. It never writes.
Open Developer tools → Actions, switch to YAML mode and run, for example:
action: wavin_sentio.read_registers
data:
type: input # input | holding | discrete
address: 7701 # register number exactly as printed in Wavin's manual
count: 8
individually: true # read one at a time so missing registers do not fail the whole readThe response contains raw values, and for 16-bit registers also fp100 (the value divided
by 100, null for the invalid marker 0x7FFF). Missing registers show error: exception 2
("illegal data address"), which simply means that register does not exist on your setup.
Register numbers are used exactly as printed in the manual (no ±1 offset).
Enable debug logging and include the log in bug reports:
logger:
default: warning
logs:
custom_components.wavin_sentio: debug| Problem | What to try |
|---|---|
| "Cannot connect" during setup | Check the IP, that Modbus TCP is enabled on the display, that the firmware is TM60014 or newer, and that port 502 is not blocked. If another Modbus client (Node-RED and so on) is connected, try closing it. This last point is a suggestion and not verified. |
| "The controller answered with a Modbus error" | Try unit ID 255 instead of 1. |
| Writes fail or have no effect | Modbus mode must be Read/write (not Read only or Write with password). |
| Target temperature does not stick | In Schedule mode the schedule wins. Setting a temperature from Home Assistant switches the zone to Manual, check that this happened. |
| Entities show unavailable | The controller returned the invalid marker 0x7FFF: no sensor connected, or a wireless sensor has not reported yet. For zones sharing a sensor, only the zone that owns it may report values. |
| Zone or circuit missing | It reports no valid value, so it is not selected by default. Select it in the options. For something newly connected, reload the integration first. |
| Occasional short errors or gaps | The controller answers "busy" during start-up and while saving its configuration. The integration retries automatically. |
| Values look wrong or a register is not what you expect | Use the debug action and open an issue. Firmware versions differ, and Wavin says the register list is not final. |
| Entity IDs are not what you expected | IDs come from device and entity names at first creation. Rename entities in the UI. They keep a stable unique ID. |
- Not implemented: ITC controllers (73xx/74xx), domestic hot water (Calefa DHW-201 and tank), buffer tank controls, ventilation, dehumidifiers, the peripheral list (thermostats and sensors with signal strength), writing names, schedules, tuning parameters (heat curve and similar), outdoor temperature override, and Modbus Write with password mode.
- The registers for these exist in the Wavin manual, so they can be added. Register dumps from installations that have them help a lot.
- Cooling is only partly handled. The mode is shown, and the climate action can report
cooling, but nobody has tested it. The climate entity offers Heat and Auto only. - Dummy rooms (zones with no thermostat or sensor) are skipped.
- One controller per config entry. Multiple controllers can each be added.
- Update interval is polling-based. There is no push from the controller.
- The Wavin manual says the Modbus interface is not meant as a user or installer interface, but for monitoring, tuning and restricting users.
- Modbus on the Sentio supports at most 32 registers per read. The integration stays within that.
- Modbus TCP has no authentication or encryption. Anyone who can reach port 502 can read and, in Read/write mode, change values, without going through Home Assistant. Keep the controller on a trusted network or VLAN, and never expose port 502 to the internet.
- Prefer Read only if you only want monitoring.
- Changing setpoints and modes affects your heating and energy use. Use Home Assistant automations that write to the Sentio with care, and avoid very frequent writes: after changes the controller runs a configuration save and may answer "busy" meanwhile.
- Frost protection, high-temperature cut-off and other safety functions run inside the Sentio. Do not disable them through any tool.
Bug reports, register dumps and pull requests are welcome.
When opening an issue, please include:
- Sentio firmware version (System information on the display) and controller model
- What hardware is connected (floor heating, radiators, boiler or heat pump, DHW, ventilation)
- Home Assistant version and integration version
- Debug logs from
custom_components.wavin_sentio - If relevant, output of
wavin_sentio.read_registersfor the registers in question
Useful register ranges to dump from setups that have them (use individually: true):
| What | Type | Start | Count |
|---|---|---|---|
| ITC1 | input / discrete | 7301 / 7301 | 10 / 8 |
| HCC1–HCC3 | input | 7701, 7801, 7901 | 8 |
| H/C source | input | 8101 | 1 |
| Boiler / heat pump | input | 8201 | 4 |
| Buffer tank | input | 8301 | 5 |
| DHW (DHW-201) | input | 6501 | 12 |
| DHW tank | input | 6601 | 8 |
| Ventilation 1 | input | 61001 | 38 |
| Dehumidifier 1 | input | 65001 | 12 |
Please read code changes carefully: this project has no automated tests against real hardware, so reviews by humans who know the Sentio are valuable.
- Written by Claude (Anthropic) from Wavin's public Sentio Modbus Manual (August 2024, firmware packages 3.2–3.4) and a community forum thread about Sentio on Modbus TCP, directed by the repository owner.
- The Modbus layer is a small, dependency-free asyncio client (
api.py), so it does not depend on thepymodbusversion in your Home Assistant. - The register logic was tested against a simulated Sentio, including "busy" answers, missing registers, invalid values, writes and the author's real register values. The Home Assistant platform code (entities, config flow) was syntax-checked and then used on the author's real installation (setup, zones, circuits, ΔT and removing unused devices), but has no automated test suite.
- Please treat the code as you would any unreviewed third-party code.