Skip to content

Baseplates: a magnet at its cap beside an H-clip or snap clip put in from above leaves open edges at 34.5 mm #85

Closed

Description

@Oliver-Johnson

Found by the sweep for #83 (PR #84). It is on main (88fef25), on a solid floor, and #84 does not touch it.

What happens. On a solid floor at 34.5 mm, with an H-clip or a wall snap clip put in from above, the magnet field takes 6.3 mm (its cap there). At that size piece A1 builds with open edges on its seam face, and Download stays on with no warning. 6 mm builds clean.

Repro (Baseplates page, default magnets from beneath, checked on main's page):

Link A1 B1
#pi=34.5&w=138&d=69&mm=custom&ml=0&mr=0&mf=0&mb=0&bw=85&bd=400&cn=hclip&ki=top&mg=1&md=6.3 4 bad edges 0
#pi=34.5&w=138&d=69&mm=custom&ml=0&mr=0&mf=0&mb=0&bw=85&bd=400&cn=snap&km=wall&ki=top&mg=1&md=6.3 3 bad edges 0

The same plates with md=6 build clean. I haven't swept other pitches or sizes yet.

Possible cause and fix. At its cap the pocket stops MOUNT_SEAM short of the cell's wall junction, where the clip's housing from above is cut into the seam face; the housing's cavity and the pocket may share a plane there, as in #64's level faces. Find where the open edges sit, then either keep the faces apart or lower the cap where the pocket meets the housing's plane, and add an audit row at 34.5 mm.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Labels

bugSomething isn't working

Projects

No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions