BQ79600 / BQ79616 Battery Monitoring System

A firmware-level battery monitoring system built on the BQ79600 (Bridge) and BQ79616 (Slaves) ICs, communicating with an STM32 MCU over UART.


Table of Contents


System Overview

The system performs battery monitoring using the following hardware:

Component Role Connection
BQ79600 Bridge Connected to STM32 MCU
BQ79616 Slaves (×N) Daisy-chained to Bridge

The Bridge interfaces with the MCU on one side and connects to multiple slave devices in a daisy-chain topology on the other. Each slave is connected in series to the next.

Reference: Section 7.3.1.3 — SPI/UART Selection | Section 5 — Pin Configuration and Functions


Communication Interface

Two communication methods are supported between the MCU and the Bridge:

  • SPI
  • UART ✅ (selected in this design)

Selected Configuration: UART at 1 Mbps baud rate.


Initialization

The initialization phase must follow proper hardware setup and covers:

  1. Wake-up sequence
  2. Auto-addressing
  3. Cell voltage configuration
  4. GPIO configuration

Wake-Up Sequence

Reference: Section 7.3.1.2 — Pings

The wake-up procedure is as follows:

  1. Deinitialize UART:

    UART_DeInit();
  2. Configure the TX pin as GPIO.

  3. Drive the TX pin LOW for approximately 2.5 ms (this value is not strict and can be adjusted).

  4. Reinitialize UART:

    UART_Init();

After wake-up, communication continues normally using UART frames.

Reference: Section 7.3.2 — Communication


Auto-Addressing

Reference: Section 7.3.2.3.1 — Auto-Addressing

Auto-addressing assigns a unique address to each device on the bus:

  • The Bridge (BQ79600)
  • Each Slave (BQ79616)

Addresses are assigned sequentially starting from 0.


Cell Voltage Configuration

Reference: Section 9.3.2.1.1 — Cell Voltage Measurements

1. Active Cell Selection

Not all 16 cells are required to be active. Configure the number of active cells using:

Parameter Value
Register ACTIVE_CELL
Page 128

2. OV/UV Thresholds

Set overvoltage and undervoltage protection thresholds:

Parameter Value
Registers OV_THRESH, UV_THRESH
Page 160

Reference: Section 9.3.4.1 — OVUV Protectors


3. OV/UV Control Mode

Configure the operating mode for OV/UV monitoring:

  • Continuous mode
  • One-shot mode
Parameter Value
Register OVUV_CTRL
Page 161

Reference: Section 9.3.4.1.2 — OVUV Control and Status


4. OV/UV Status Check

Verify that OV/UV monitoring is active:

Parameter Value
Register DEV_STAT[OVUV_RUN]
Page 135

Cell Voltage Reading

Reference: Section 9.5.4.6 — ADC Measurement Results (Page 140)

Data Format

Each measurement is 16-bit, composed of:

  • High byte
  • Low byte

Voltage Calculation

Voltage (V) = ADC_Value × VLSB_ADC

Where:

  • VLSB_ADC = 0.00019073 V/LSB

Reference: ADC Resolution (Page 14)

Function Signature

uint8_t readBoardVoltages(uint8_t  boardNum,
                          uint8_t  numCells,
                          int     *totalV,
                          uint16_t *cellVoltages);

Data Storage

All cell voltage readings from all slave boards are stored in a 2D array:

uint16_t cellVoltages_board[SLAVEBOARDS][16];

GPIO & Temperature Configuration

Reference: Section 9.3.2.1.2 — Temperature Measurements

GPIO Modes

GPIO pins support the following operating modes:

Mode Description
Digital Input Standard logic input
Digital Output Standard logic output
ADC Only Analog measurement only
ADC + OT/UT ✅ Used in this design

1. OT/UT Thresholds

Set over-temperature and under-temperature protection thresholds:

Parameter Value
Register OTUT_THRESH
Page 161

Reference: Section 9.3.4.2 — OTUT Protector


2. Comparator Threshold

Parameter Value
Register OTCB_THRESH

3. TSREF Enable

Enable the internal reference voltage for temperature sensors:

Parameter Value
Register CONTROL2[TSREF_EN]
Page 132

Reference: Section 9.3.1.6 — TSREF

Function: Provides a 5V output to power temperature sensors. The ground reference is taken from the same slave board.


4. GPIO Configuration

Set all relevant GPIOs to ADC + OT/UT mode using the following registers:

Register Page
GPIO_CONF1 162
GPIO_CONF2 162
GPIO_CONF3 162
GPIO_CONF4 162

Reference: Section 9.5.4.9 — GPIO Configuration


5. OT/UT Control Mode

Configure the operating mode for OT/UT monitoring:

  • Continuous mode
  • One-shot mode
Parameter Value
Register OTUT_CTRL
Page 161

Reference: Section 9.3.4.2.2 — OTUT Control and Status


6. OT/UT Status Check

Verify that OT/UT monitoring is active:

Parameter Value
Register DEV_STAT[OTUT_RUN]
Page 135

GPIO Voltage Reading

Reference: Section 9.5.4.6 — ADC Measurement Results

Voltage Calculation

Voltage (V) = ADC_Value × VLSB_DIAG

Where:

  • VLSB_DIAG = 152.59 µV/LSB

Reference: Electrical Characteristics (Page 15)

Function Signature

float readGPIOVoltage(uint8_t   BID,
                      uint8_t   GPIO_NUM,
                      uint16_t *raw_value_ptr);

Fault Handling

After completing cell voltage and temperature monitoring, the system must detect and respond to faults.

Fault Types

Fault Description
OV Over Voltage
UV Under Voltage
OT Over Temperature
UT Under Temperature

Required Actions

  1. Read fault status registers
  2. Identify the fault type
  3. Take appropriate action based on severity:
    • 🔴 Shutdown — critical fault, halt operation
    • 🟡 Warning — non-critical, alert the system
    • 📋 Logging — record the event for diagnostics

System Flow Summary

The complete system execution flow proceeds as follows:

1. Hardware Setup
       ↓
2. Initialization
   ├── Wake-Up Sequence
   └── Auto-Addressing
       ↓
3. Cell Voltage Configuration
   ├── Active Cell Selection
   ├── OV/UV Threshold Setup
   ├── OV/UV Control Mode
   └── Status Verification
       ↓
4. Cell Voltage Reading
       ↓
5. GPIO / Temperature Configuration
   ├── OT/UT Threshold Setup
   ├── Comparator Threshold
   ├── TSREF Enable
   ├── GPIO Mode Configuration
   ├── OT/UT Control Mode
   └── Status Verification
       ↓
6. Temperature Reading
       ↓
7. Fault Detection & Handling