Talk to and flash the firmware of a Creality CFS (Creality Filament System)
directly from a K1-series printer, over its RS485 bus, using nothing but the
printer's own Python. No mcu_util_485 binary required.
Why this exists: on some K1-series printers the CFS firmware is meant to be flashed by
/usr/bin/mcu_util_485over RS485 (see/etc/init.d/S13mcu_update), but that binary is missing from the firmware image. As a result the printer can talk to the CFS (versions, material handling) but can never update it, so an older CFS stays stuck on its factory version. The onlymcu_util_485you can find elsewhere is built for a different CPU architecture (ARM) and won't run on the printer's MIPS CPU.
cfstoolre-implements the RS485 flash protocol in pure, standard-library Python, so it runs natively on the printer regardless of CPU — or on a Pi/PC.
The flash command erases and rewrites the CFS microcontroller. Getting it
wrong can permanently damage (brick) the CFS board.
- This is a community-reconstructed tool, not Creality's official flasher.
- Always run a DRY RUN first (that's the default) and check the output.
- Connect exactly one CFS for flashing. Stop Klipper so it doesn't fight for the bus. (The tool refuses to flash when it sees more than one CFS.)
- Keep power rock-stable during writing. Do not unplug or power off mid-flash.
- Use at your own risk. No warranty (see LICENSE).
Good news on recoverability: the erase step wipes only the application flash region, not the bootloader. So an interrupted flash usually leaves the CFS in its bootloader, and you can simply run the flash again. A true permanent brick requires corrupting the bootloader region, which the normal flow never writes to.
The printer firmware stayed on 2.3.5.34 the whole time; only the CFS units were upgraded, one at a time, straight from their factory versions.
Before — CFS 1 shipped on 1.1.3, CFS 2 (a refurb) on 1.4.2:
After flashing CFS 1 — both on 1.4.2:
After flashing both to 1.5.0 — printer still 2.3.5.34, both CFS on 1.5.0:
(The "Version checking" screen reads the live version from each CFS, so it
reflects the real on-CFS firmware — independent of version.json.)
And the CFS happily doing multi-color work after the update (colour changes on the claws and faces — this doesn't prove anything about the flasher, the version screen above does that, but it's the real-world result):
| Device | Bus | Naming | Supported? |
|---|---|---|---|
| Original CFS, G32 | RS485 (CH340) | cfs0_050_G32-… |
✅ Tested (1.1.3 → 1.4.2 → 1.5.0 → 1.5.3 verified on real hardware) |
| Original CFS, G30 | RS485 (CH340) | cfs0_050_G30-… |
|
Any cfs0 app version |
RS485 (CH340) | …cfs0_000_113/142/150/… |
✅ Version-agnostic |
| CFS "cfs6" generation | — | cfs6_100_G31 / cfs6_220_000 |
❌ No (different hardware; blocked by the tool) |
| CFS-C | CAN (cmd_iap) |
— | ❌ No (different product & protocol) |
Only G32 has actually been flashed and verified on real hardware (1.1.3 → 1.4.2
→ 1.5.0 → 1.5.3). G30 is expected to work but is unconfirmed — if you have a G30 CFS, a
dry run (cfstool.py flash) is safe and a report back would be very welcome.
Confirmed printer models: K1 Max (the author) and K1C (reported working by a user). The flow should be the same on any K1-series printer whose CFS is on the CH340 RS485 adapter.
- Works on K1-series printers where the CFS is on the CH340 USB-RS485 adapter
(VID
1a86) — and in principle on any Linux host with that adapter (printer, Pi, PC). - The tool reads the connected CFS's hardware (G30/G32) and refuses a mismatched firmware file, so you can't accidentally flash the wrong variant.
- Multiple CFS units: flash them one at a time, with only one connected at a
time. Reading them while all are connected works with
--box N. See Multiple CFS units.
- A K1-series printer (or any Linux host) with root shell access.
- Python 3 (standard library only — no pip installs).
- The CFS connected via its USB-RS485 adapter (CH340, VID
1a86), which shows up as/dev/serial/by-id/usb-1a86_USB_Serial-if00-port0→ttyUSB0. - The firmware
.binyou want to flash. Not included here (it is Creality's copyrighted firmware). You already have it on your printer at/usr/share/klipper/fw/cfs/, or inside a newer official firmware image.
Copy cfstool.py onto the printer to /usr/data/ (that folder survives reboots,
and all commands in this README use that path), then stop Klipper so the RS485 bus is
free:
# find and stop the klipper service (name varies)
ls /etc/init.d/ | grep -i klip
/etc/init.d/S55klipper_service stopConnect only one CFS.
1. Your CFS firmware lives here on the printer — /usr/share/klipper/fw/cfs/.
These cfs0_050_G32-cfs0_000_*.bin files are what gets flashed (keep a copy as a
backup; here an old 1.1.3 Backup folder sits next to them).
2. Find the Klipper service name (it varies between firmware versions):
3. Stop Klipper so it doesn't use the RS485 bus while you talk to the CFS:
4. Put cfstool.py on the printer (e.g. in /usr/data/) with an SFTP client
such as FileZilla:
Now you're ready to run query, diag, probe, or flash (below). The commands
use the full path /usr/data/cfstool.py, so they work from any directory.
When you're done, start Klipper again: /etc/init.d/S55klipper_service start.
All commands below use the full path
/usr/data/cfstool.py, so you can copy and paste them and they work from any directory — nocdneeded. If you put the file somewhere else, just change/usr/data/to wherever it is.Always start with
python3. (Plaincfstool.py querywon't work — the file isn't on your PATH.)
python3 /usr/data/cfstool.py queryPrints a comm test, the device identity/UUID, GET_VERSION_SN, and hardware
status. The leading digits of the version string are the firmware version
(e.g. 113… = 1.1.3, 142… = 1.4.2). This is the easiest way to check what a CFS
is running, before and after flashing.
python3 /usr/data/cfstool.py diagSame idea as query, but formatted into labelled fields — communication, firmware,
serial number, UUID, hardware status, and RFID/filament per slot:
Communication : OK (ACK)
Firmware : 1.5.0
Serial number : 10000854965B625BAJG
UUID : 54 62 30 02 18 53 33 11 52 35 38 32
Hardware stat : 10 20 30 40 50 60 00 ...
RFID/Slots : A:...;B:none;...
It sends only safe read commands. The hardware variant (G30/G32) and
bootloader version come from probe (they need bootloader mode). Motor state and
environment sensors (temp/humidity, filament sensors) are deliberately not queried
— those commands aren't clean read-only in the protocol, and this tool never sends an
unverified command to the CFS.
python3 /usr/data/cfstool.py probeEnters the bootloader, enumerates + addresses the CFS, reads the bootloader version and the flash sector size, then starts the app again. Writes nothing. Useful to confirm bootloader access works before flashing.
Example output (a CFS reporting cfs0_050_G32-cfs0_000_142, sector 0xe0 → 128-byte
chunks):
Pick from a folder (recommended): with no file given, flash scans the
printer's CFS firmware folder (/usr/share/klipper/fw/cfs), reads the connected
CFS's current version/hardware, lists the available firmware, and then asks you
which version to install (interactively). You don't put the filename on the
command line — you choose it from the menu. Incompatible files (wrong hardware,
e.g. G30 vs G32) are flagged and blocked.
# DRY RUN (default): scan, ask which version, validate - writes NOTHING
python3 /usr/data/cfstool.py flashThe command is just flash; the version choice happens at the prompt it shows:
Scanned /usr/share/klipper/fw/cfs: found 3 firmware file(s).
Mode: DRY RUN (no erase/write)
enter bootloader TX f7 eb 03 ff 56 cf
enumerate 0xA1 OK RX ...
assign 0x01 0xA0 OK RX ...
-> current version: 'cfs0_050_G32-cfs0_000_142'
get sector 0xF0[03] OK RX ...
-> sector 0xe0 => chunk = 128 bytes
Available firmware (connected CFS: hardware G32, version cfs0_050_G32-cfs0_000_142):
! [0] cfs0_050_G30-cfs0_000_142.bin v1.4.2 <- WRONG HARDWARE (G30), do not pick
[1] cfs0_050_G32-cfs0_000_142.bin v1.4.2 <- already installed
[2] cfs0_050_G32-cfs0_000_150.bin v1.5.0
Which firmware to install? [number, or q to cancel]: 2
Selected: cfs0_050_G32-cfs0_000_150.bin (v1.5.0)
size: 175104 bytes
PLAN: 1.4.2 -> 1.5.0 (175104 bytes, 1368 frames of 128, last 128)
>>> DRY RUN complete. NOTHING was written.
>>> If the plan looks right, re-run with --flash to write.
Real flash: the exact same command plus --flash. It scans and asks the
same way, then actually writes:
python3 /usr/data/cfstool.py flash --flash...same scan + prompt...
Which firmware to install? [number, or q to cancel]: 2
Selected: cfs0_050_G32-cfs0_000_150.bin (v1.5.0)
PLAN: 1.4.2 -> 1.5.0 (175104 bytes, 1368 frames of 128, last 128)
Erase and write cfs0_050_G32-cfs0_000_150.bin now? Type YES to flash: YES
=== FLASH START - DO NOT POWER OFF ===
erase 0xF0[06] OK RX f7 01 04 00 f0 75 00
request 0xF0[01] OK RX f7 01 04 00 f0 75 00
fw len 0xF0 OK RX f7 01 04 00 f0 75 00
-> sending 1368 frames ...
50/1368 frames (6400/175104 bytes)
100/1368 frames (12800/175104 bytes)
...
1368/1368 frames (175104/175104 bytes)
startup 0xF0[02] OK RX f7 01 04 00 f0 75 00
=== FLASH END ===
Next: POWER-CYCLE the CFS (it stays in the bootloader until you do).
Verify with: python3 /usr/data/cfstool.py query
Look at GET_VERSION_SN - the leading digits are the version.
Only an exact, upper-case YES starts the erase. Anything else (including yes)
cancels without writing. The firmware number prompt likewise accepts only a plain
number, so a pasted shell command that lands in the prompt cannot pick a firmware.
Type the commands one at a time instead of pasting several lines at once.
Power-cycle the CFS after the flash — this matters. On at least some original G32 CFS units, right after a completed flash the CFS will not answer APP-mode
query/diagcommands, and the tool's own post-flash version read may come back empty — so the update can look like it failed when it actually succeeded. Physically power the CFS off and back on (only after=== FLASH END ===, never during the flash), then start Klipper again and confirm withquery. (Reported by a user on a K1C, and matches the author's experience on a K1 Max.)
After it finishes, power-cycle the CFS, then confirm:
python3 /usr/data/cfstool.py query # GET_VERSION_SN should now start with 150...You can also skip the menu and point at a directory or a single file:
python3 /usr/data/cfstool.py flash /path/to/fw/dir # scan that directory, then ask
python3 /usr/data/cfstool.py flash /usr/share/klipper/fw/cfs/cfs0_050_G32-cfs0_000_150.bin --flash # one file, no menucfstool is version-agnostic — it flashes any cfs0_…_<ver>.bin (1.4.2, 1.5.0,
and future releases) with no code changes; it reads the target version from the
file and the current version from the CFS.
The dry run enumerates the CFS, reads its current version and sector size, validates the file, and prints the plan — without touching flash. Safety gates abort on a wrong-hardware file, on a file that isn't a CFS image, if the CFS already runs that version, or if no single CFS is found.
During a real flash do not power anything off until you see === FLASH END ===.
The printer shows the CFS version based on the version.json next to the firmware.
After a real flash, cfstool automatically keeps that file in sync — it backs
up the existing version.json (timestamped, e.g. version.json.bak_2026-07-28_2325)
and then sets the flashed hardware's entry to the new version. Other entries (e.g. a
G30 block, or the newer cfs6 block) are left untouched. In a dry run it only
previews the change and writes nothing.
Add --no-json if you don't want the file touched at all:
python3 /usr/data/cfstool.py flash --flash --no-jsonThis is purely cosmetic for the printer's UI; the actual firmware on the CFS is what
query reports and does not depend on version.json.
Then power-cycle the CFS and verify:
python3 /usr/data/cfstool.py query # GET_VERSION_SN should now start with the new versionWith two or more CFS in series, flash them one at a time with only that one connected (unplug the others from the bus, so the one you flash sits directly on the printer). That is the proven path. Both boxes on the author's K1 Max went to 1.5.3 this way.
The tool protects you if you forget: without --box it first asks addresses
0x01–0x04, and if more than one CFS answers it stops before sending the
enter-bootloader broadcast. If the boxes are not addressed yet, it stops when more
than one answers the enumerate.
Reading individual boxes works with all of them connected, via --box N. Let
stock Klipper run ~30 s first so the boxes get their addresses, then stop it:
python3 /usr/data/cfstool.py query --box 2 # or: diag --box 2
python3 /usr/data/cfstool.py probe --box 2 # only box 2 enters the bootloader
python3 /usr/data/cfstool.py flash --box 2 # dry run: plan for box 2, writes nothingprobe --box and the flash --box dry run send enter-bootloader only to that box
and check before and after that every other box is still in app mode. Afterwards
the box sits in the bootloader: start stock Klipper and wait ~30 s (its loader check
restarts the app), or power-cycle that box.
flash --box N --flash is refused. Flashing through that addressed path ACKs
every frame but leaves the box without a valid app (details in
PROTOCOL.md).
Symptom: query gets no answer, but cfs_probe.py or probe --box N shows the box
in LOADER mode, and the bootloader version ends in a dash with nothing after it
(cfs0_050_G32-). That means no valid app is installed. The bootloader itself is
fine, so re-flash:
- Stop Klipper:
/etc/init.d/S55klipper_service stop - Connect only that CFS, directly to the printer.
- Power-cycle that CFS while Klipper stays stopped. (If stock Klipper addressed
it in the bootloader, it ignores the enumerate and
flashreportsenumerate 0xA1 FAIL.) python3 /usr/data/cfstool.py flash→ pick a version → dry run looks right →python3 /usr/data/cfstool.py flash --flash→YES.- Power-cycle the CFS, check with
query, then reconnect the other boxes and start Klipper.
--dev <port>— serial device (default/dev/serial/by-id/usb-1a86_USB_Serial-if00-port0). Some printers have a second1a86adapter (…USB_Single_Serial…) that is not the CFS bus.--box <N>— talk to boxN(1–4) when several CFS are connected:query,diag,probeand theflashdry run. Not for a real flash.--no-json— don't touchversion.jsonafter a real flash.
The CFS is an RS485 slave. The printer normally: (1) broadcasts an "enter
bootloader" frame, (2) enumerates the bus and assigns the CFS address 0x01,
(3) drives an erase → request → length → data → startup sequence. cfstool
reproduces exactly this. See PROTOCOL.md for the wire format and
the full command sequence.
Extra files, all optional and not needed to flash a CFS:
FIRMWARE-CHANGES.md— what changed between the CFS firmware versions 1.1.3, 1.4.2, 1.5.0, 1.5.2 and 1.5.3, reconstructed from the images (Creality publishes no changelog for the CFS).cfs_probe.py— a read-only diagnostic. It sends only safe identity/version queries (ff 14,ff a2) plus an enumerate, dumps the raw replies, and ends with a summary of every box: address, type, mode (app/bootloader), UUID and firmware version. No risk of a write. Works with several CFS connected (it queries each address, and lists boxes that have no address yet).k1_cfs_bus.py(GPLv3) — a reactor-friendly RS485/CAN transport for using the CFS from mainline Klipper, using the sameF7framing ascfstool. It is derived from grant0013'sk2_motor_bus.pyand contributed toward the K2-OpenKlipper CFS stack. Not involved in flashing.
(Observations from analysing the stock printer module and the CFS firmware — not official docs.) There are two separate pieces of software, and people often confuse them:
- Printer side — a Klipper module (
[box], implemented in a compiledbox_wrapper*.so) that exposesBOX_*G-code commands (e.g.BOX_GET_RFID,BOX_EXTRUDE_MATERIAL,BOX_SET_PRE_LOADING). Internally these callcommunication_*methods that send RS485 messages. - CFS side — the firmware on the CFS's own MCU (the
.binthis tool flashes), which receives those RS485 messages and runs the actual motor/RFID/ feeding logic (STATE_PRELOAD, feeder start/stop, RFID read/write, …).
They map like a chain, they are not the same command set:
G-code BOX_SET_PRE_LOADING
→ printer: BoxAction.communication_set_pre_loading
→ RS485 message on the bus
→ CFS firmware: STATE_PRELOAD / feed process / feeder start
Consequences worth knowing:
- A config or macro can only call
BOX_*commands that the printer's compiled module already contains. You can't add new commands (or port another model's features, e.g. the K2's filament drying commands) by editing a.cfg— that logic isn't in your printer's module, and the modules are model/CPU/Python specific (K1 Max = MIPS/py3.8, K2 = ARM/py3.9), so you can't just swap them. - CFS firmware updates change what the CFS does behind an unchanged interface.
The feeding/preload refinements in CFS 1.5.0 are internal to the CFS — the
RS485 opcodes didn't change, so a stock printer still drives them fine. 1.5.2
adds an optional new mode to an existing command; a printer that never asks for
it gets the old behaviour. That's why flashing the CFS newer works without
touching printer firmware. Details per version:
FIRMWARE-CHANGES.md. - Some features need both sides. RFID usage tracking (the CFS writes used
filament back to the tag since 1.4.2) only works end-to-end because the printer
also has
BOX_GET_RFIDto ask for it.
Can I upgrade only the CFS and keep my printer firmware?
Yes — that's exactly what this tool is for. The CFS runs its own firmware on its
own microcontroller; cfstool flashes that firmware over RS485 without touching
the printer firmware. (Demonstrated in practice: printer left on 2.3.5.34, both
CFS units taken from their factory versions up to 1.5.0 — see the photos above.)
"Isn't the CFS firmware just a protocol bound to the printer, not stored on the CFS?"
No. The CFS has its own GD32F303 MCU running RT-Thread, with the firmware stored
in its own flash. The .bin files are real ARM Cortex-M images (vector table, reset
handler, etc.). You can read the version straight off the CFS (query) and this tool
erases/writes that on-CFS flash. There is a version coupling — the printer bundles a
CFS firmware and normally force-flashes the CFS to match, and the RS485 feature set
must line up between versions — but that coupling exists because the printer writes
the CFS firmware, not because the CFS has none.
Can I downgrade (flash an older version)?
Yes. The flash is direction-agnostic — it erases the application region and writes
whichever .bin you pick, so an older version flashes exactly like a newer one; just
choose the lower version from the menu (or pass its file path). The only version gate
refuses re-flashing the version that is already installed. Two honest caveats:
upgrades are what has been verified on real hardware (1.1.3 → 1.4.2 → 1.5.0 → 1.5.3)
— a downgrade runs the identical flash path but hasn't been explicitly tested; and
going below a feature threshold changes behaviour (e.g. below 1.4.2 the CFS loses
the reworked RFID handling, such as writing used filament back to the tag, and the
printer may then flag it as "needs update" even though the flash itself succeeded).
See FIRMWARE-CHANGES.md for what each version adds.
Do I need the version.json next to the firmware?
No. cfstool reads the current version from the CFS and the target from the .bin
filename/contents. version.json is only used by the printer's own (here: missing)
auto-flash mechanism.
Will it work for future versions / new CFS hardware?
For cfs0-family boxes, yes — any cfs0_…_<ver>.bin works. Newer bundles have begun
listing a different cfs6-family hardware too; that is a separate device type and is
out of scope here (the tool blocks mismatched hardware).
I'll be upfront: I'm not a programmer. I don't really know how to code. This
tool was built with the help of AI (Anthropic's Claude and OpenAI's ChatGPT) —
the AI did the reverse-engineering of the stock mcu_util_485, worked out the RS485
flash protocol, and wrote the Python. What I brought was the printer and CFS
hardware, the goal, all the trial-and-error testing on real hardware, and the final
decisions (including hitting "flash").
So please read the code with that in mind, and use it at your own risk. Every step was verified against the stock tool and confirmed on live hardware before it was trusted — nothing here was guessed — but it is still a community-reconstructed tool, not an official Creality one. Reviews, fixes, and improvements from people who do know what they're doing are very welcome.
- RS485 bus/command documentation cross-checked against the excellent archworks.co K2-Plus reverse-engineering write-up.
- The flash/bootloader sequence was derived by analyzing Creality's own
mcu_util_485for interoperability. No Creality code or firmware is included. - grant0013 (Hark Tech) / K2-OpenKlipper —
the reactor-safe RS485/CAN bus (
k1_cfs_bus.py) is derived from hisk2_motor_bus.py(GPLv3), and the CFS protocol was cross-checked both ways, including the0xA2device-type/mode reading, through the K2-OpenKlipper collaboration.
MIT — see LICENSE. Provided as is, without warranty. You are
responsible for anything you flash.
One exception: k1_cfs_bus.py is GPLv3, not MIT — it is derived from
grant0013's k2_motor_bus.py (K2-OpenKlipper, GPLv3) and carries its own GPLv3
header. It is optional and not used by the flasher; everything else in this repo
is MIT.
This is an independent, community-built tool. It is not affiliated with, authorized by, or endorsed by Creality. "Creality" and "CFS" are trademarks of their respective owners and are used here only to describe compatibility. No Creality firmware, binaries, or other proprietary files are included in this repository — you supply your own firmware from your own device. The protocol notes were derived by observing and analysing an existing device for interoperability. Use at your own risk.