Problem

On the "Dynamic Current" step, an appliance without dynamic current could not proceed while the "Cheap-window target current" field held a value (pre-filled, or left over from an earlier dynamic configuration). The validator returned cheap_grid_target_current_requires_dynamic and the user had to clear the field manually.

Change

  • Add and reconfigure flows: when dynamic current is off, the cheap-window target current is dropped from the input instead of raising an error. The existing cleanup then removes any stored value, so no stale setting survives.
  • The now unused error string is removed from strings.json and translations/en.json.

Validation

  • The rejection test is replaced by two regressions (add flow with a stale stored value, reconfigure from dynamic to non-dynamic); the dynamic-current acceptance test is unchanged.
  • Full suite on HA 2025.8 / Python 3.13: 1290 passed. scripts/check_public_tree.py: 0 findings.

Closes #68

…oCasa#68)

The current step rejected a pre-filled cheap-window target current when
dynamic current was off, so the user had to clear the field manually.
The value is only meaningful for dynamic-current appliances; it is now
dropped silently in both the add and reconfigure flows.