Skip to content

feat(dynamic): add spatial-temporal voltage risk diagnostics - #4

Open
BurhanAbdullah wants to merge 5 commits into
mainfrom
feat/dynamic-spatial-temporal-risk
Open

BurhanAbdullah wants to merge 5 commits into
mainfrom
feat/dynamic-spatial-temporal-risk

Conversation

@BurhanAbdullah

Copy link
Copy Markdown
Owner

Summary

Adds an independent evaluator-side metric module for the IEEE 39-bus transient-stability benchmark. The existing Integral of Violation (IoV) scalar averages voltage violations across buses; this extension separately quantifies spatial concentration and temporal persistence so localized but severe excursions do not disappear inside a fleet-wide average.

New capability

  • Per-bus time-integrated normalized undervoltage and overvoltage exposure, reported as both mean and worst-bus values.
  • Fraction of buses experiencing at least one threshold crossing.
  • Upper-tail mean of sample-level spatial-average violation to expose brief severe excursions.
  • Longest sampled contiguous violation duration, using actual nonuniform time intervals.
  • Strict validation of time ordering, finite values, metric thresholds, and tail fraction.
  • Offline synthetic tests; no licensed PowerFactory install or API is required.

The module does not change the published scalar score or the benchmark's instability flag. The accompanying document clarifies interpretation and limitations; the tail statistic is described as CVaR-like, not formal CVaR.

Validation

Tests are included under benchmarks/dynamic/level2/test_spatial_temporal_risk.py.

Scope

This is a standalone metric extension, not a patch to an existing defect. It is evaluator-side and does not expose hidden test memory or ground-truth labels to agents.