Skip to content

Guided sensor dialogs, bundled ArgyllCMS first, Italian translation - #1

Open
Victory61 wants to merge 27 commits into
AndriyOrlov:mainfrom
Victory61:main
Open

Victory61 wants to merge 27 commits into
AndriyOrlov:mainfrom
Victory61:main

Conversation

@Victory61

Copy link
Copy Markdown

Hi Andrii, thank you for HDRDisplayCalibrate. I calibrated my LG UltraGear with it and the result is much better than my previous profile made by eye.

I made a few changes in my fork that you may want to include. Feel free to take all, some or none of them.

  1. Guided sensor dialogs (new src/Pages/ProbeGuide.cs)
  • Before HDR step 1 and before Verify: a "Place the sensor on the screen" dialog with a front/side diagram (centre, diffuser open, counterweight behind), a short checklist and a note that the screen turns black, grey, white and coloured for a few minutes.
  • Before HDR steps 2-5: an "Is the sensor still in the centre?" reminder.
  • After step 5 and after Verify: a "you can remove the sensor" message (after step 5 also a reminder to set SDR content brightness back).
  • Cancel in any dialog stops before anything is measured.
  1. Bundled ArgyllCMS always first (src/Core/Argyll.cs, src/Pages/DevicePage.cs)
  • If Argyll\bin exists next to the exe it is used before the saved "bin folder", so an old setting cannot point to another ArgyllCMS. The bin folder field becomes read-only and Apply is hidden.
  1. Italian translation (src/i18n/it.json, "Italiano" added in src/I18n.cs), all 392 strings including the new ones.

Notes:

  • The new strings have Ukrainian text in S.T(); please check it, as I do not speak Ukrainian. Other languages fall back to English for them.
  • Built with your GitHub Actions workflow and tested on Windows 11 with an i1Display Pro: dialogs, Italian interface and bundled ArgyllCMS detection. The dialogs between steps and at the end have not yet been seen during a full calibration.
  • I made these changes with the help of Claude (AI).
  • The changed files carry a "Modified by DMD61" note and NOTICE lists the changes, as Apache-2.0 asks; feel free to reword or remove them.

Thanks again,
DMD61 (Victory61)

@Victory61

Copy link
Copy Markdown
Author

Hi Andrii,

A short update: I have added more changes to this pull request (they come automatically from my main branch). All of them were tested today on Windows 11 with a full HDR calibration on an LG UltraGear and a Calibrite Display Pro.

  • The guided sensor dialogs were checked in a complete calibration (place, check between steps, remove).
  • The app opens on HDR calibration for an HDR monitor and on SDR calibration otherwise, switching Windows HDR on/off by itself; HDR calibration is greyed out on a monitor without HDR.
  • HDR page: a short "Before you start" box (OSD brightness read over DDC/CI), numbered steps in the profile prompt, a warning before step 2 (white screen), automatic scroll to the next step.
  • Step 5: name of the final profile, report folder and format (PDF/HTML), and a colour check of 24 colours (ΔE2000) added to the final verification.
  • Closing window: "SDR content brightness" back to its previous value (with a tick when it is), test profiles and work files deleted, a reminder for removing profiles by hand.
  • "Export report" (PDF or HTML) on the HDR and Verify pages; chart labels and legends no longer overlap.

The commit "Add files via upload" is version 3 of these changes. The details are listed in NOTICE.
As before, I made these changes with the help of Claude (AI). Please take only what you find useful: I can split the changes or make any of them optional if you prefer.

Thanks,
DMD61 (Victory61)

@Victory61

Copy link
Copy Markdown
Author

Hi Andrii,

a short summary of what this pull request contains now (it updates by itself with every push to my fork):

  • Guided sensor dialogs (where to place and remove the probe), ArgyllCMS bundled and used first, Italian translation.
  • HDR wizard: opens on HDR or SDR calibration according to the monitor and switches Windows HDR on/off; short "Before you start" box (OSD brightness read over DDC/CI); step 1 does not start unless "SDR content brightness" is at 100; the white screen of step 2 is explained; name of the final profile; closing window (SDR brightness back to its previous value, test profiles and work files deleted).
  • Fix in HdrPipeline: the grey curves were built by inverting the readings point by point, so the probe noise left flat stretches and jumps in the MHC2 LUT (visible banding, coloured where R/G/B jumped at different levels). The curves are now smoothed and always rising; on my monitor the banding is gone and the 24-colour check gives ΔE2000 mean 0.96, max 2.06.
  • HDR colour check (24 colours, ΔE2000) in the final verification; report saved automatically as PDF or HTML; report export also in Verify & report.
  • New "Test patterns" page for checking a calibration by eye, also as an independent check (grey ramp, grey steps, shadow and highlight detail, colour ramps, saturations, reference colours, full screens), each with what a correct result and a defect look like.

All changes are listed in NOTICE, with the credit to your original work kept. I'd be glad if you could take a look; feel free to take only the parts you find useful (the HdrPipeline fix is in src/Core/HdrPipeline.cs and is independent of the rest).

Thanks for HDRDisplayCalibrate!
DMD61 (Victory61)

@Victory61

Copy link
Copy Markdown
Author

A ready-to-install build with all these changes is now available here:
https://github.com/Victory61/HDRDisplayCalibrate/releases/tag/v0.3.0-DMD61.9

The ArgyllCMS card on the Display & probe page is hidden when ArgyllCMS is bundled with the app (installer build). It appears only when the bin folder has to be set by hand. Version 0.3.0-DMD61.10.
- Room light also read when ArgyllCMS prints only the XYZ result; wrong diffuser position refused.
- Measurement screen shows stage, pass, patch and time left, with a note that dark patches take longer.
- SDR calibration: Medium quality and 250 patches by default, estimated time shown.
- One-time notice about the Windows firewall question for ArgyllCMS.
- Brightness question: no DDC/CI option when the screen has none; sensor put back before going on.
- Log restarts above 5 MB (old one kept as log.old.txt).
- Italian strings.
…with the sensor on screen)

- Steps in the order they are done; optional room light measured before the sensor goes on the screen.
- Standard / Advanced / Maximum modes like Calibrite PROFILER (119 / 211 / 461 patches), Standard by default, estimated time from a real run.
- No message while the sensor is on the screen: luminance limited automatically, firewall rules added before, profile set as the display default by the app, summary at the end.
- Status line: "Phase X of N", pass and patch; dimmer on dark patches.
- Clearer room-light picture; CIECAM02 option explained; verification shows 65 patches.
- Clear message when the diffuser is left over the lens.
- HDR calibration greyed out for screens without HDR.
- Italian strings.
… screen

- One choice only, the mode (Standard 119, Advanced 211, Maximum 461 patches), with patches and estimated time next to it.
- Profile name with date and time, asked before the sensor is placed together with the report folder and format.
- Report saved automatically at the end, as in the HDR calibration.
- One measurement screen from the first patch to the last: no desktop between the phases.
- Button renamed "Measure ambient light".
- Italian strings.
…t the end

- SDR mode named just "Standard" (also in the "What to do" guide).
- At the end of the SDR calibration the program asks whether to delete the work files, as in the HDR calibration; the report and the installed profile are kept.
- Italian strings.
…ation

- Brightness check before the SDR calibration starts: if the white is close to the target, the calibration starts at once.
- With DDC/CI the program adjusts the monitor brightness by itself.
- Without DDC/CI a small window in a corner of the screen shows the white measured live while the user changes the brightness; the value turns green when it is right (Continue / Continue anyway / Cancel). The sensor is never touched.
- The summary explains what happens when the screen was left much brighter or darker than the target.
- New file src/Pages/BrightnessCheck.cs; Italian strings.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant