This repository hosts application packages and integrations for the Shelly Power Dongle (SPD), targeting CAN and RS485 devices.
Every package developed for a MODBUS device in this repository must follow these requirements:
- Dynamic Modbus ID Virtual Component. The device's Modbus slave/unit ID must never be hardcoded into the script logic — it must be exposed as a
numberVirtual Component so it can be reconfigured from the Shelly app without redeploying code, following the pattern established in pkgs/marstek/venus_e/revision/app.shelly.js:- Component config:
min: 1,max: 247(the valid Modbus unit-ID range),persisted: true(survives reboot),meta.ui.view: "field"— a precise numeric text-entry input, not"slider", since being off by even one value breaks communication with the device entirely. - A
getSlaveId()-style helper reads the component's live value on every request (not just once at script init), clamps/rounds it into the valid range, and syncs the clamped value back to the component if it was out of range — mirroring howgetControlPower()handles the Control Power component in the same script. - Every MODBUS frame-building function (both read and write) must call this helper for the unit-ID byte, instead of referencing a static config constant.
- This component's
mapping.jsonentry must carry themodbus_idrole (see Roles below).
- Component config:
This set of requirements is not closed — more will be added as new packages establish new conventions.
Each Virtual Component entry in a package's mapping.json carries a role field — a standardized tag describing what the component semantically represents (independent of its device-specific key/name). This lets tooling reason about components generically across different vendor integrations (e.g. any component tagged battery_level means the same thing regardless of which package defines it).
The currently defined roles are:
| Role | Data type | Description | Example use case |
|---|---|---|---|
auto_balancing |
boolean | Whether automatic (e.g. cell/load) balancing is enabled | Battery pack auto cell-balancing toggle |
auto_start |
boolean | Whether the device automatically starts/resumes operation | Generator or pump auto-start enable |
average_temperature |
number | An averaged temperature reading across multiple sensors | Average of several battery cell temperatures |
backlight_enable |
boolean | Toggle for a display's backlight | Thermostat screen backlight on/off |
battery_consumption |
number | Power/energy drawn from the battery | Instantaneous discharge power |
battery_level |
number | Battery state of charge | SOC, in % |
battery_power |
number | Instantaneous battery power, bidirectional (positive = discharge, negative = charge) | Marstek Pbat-style live power reading |
battery_state |
text | The battery's current operating state | charging / discharging / idle / fault |
brightness |
number | A numeric brightness/dimming level | Display or light brightness, in % |
charge_command |
enum | A command that triggers a charge/discharge/stop action (not a passive mode readback) | Marstek ChgCmd-style dropdown: Stop / Force Charge / Discharge |
charged |
boolean | Boolean flag: battery/device is fully charged | — |
charging_power |
number | The power setpoint applied on the next charge or discharge command (bidirectional use, despite the name) | Marstek ChgPowerSet-style control power field |
close |
button | Command to close an actuator | Close a valve, cover, or gate |
curr_temperature |
number | Deprecated — legacy alias of current_temperature; use that instead |
— |
current |
number | Electrical current reading | Amps |
current_humidity |
number | The current/live relative humidity reading | — |
current_limit |
number | A configured maximum current limit | Charge current cap |
current_temperature |
number | The current/live temperature reading (preferred over curr_temperature) |
— |
enable |
boolean | Generic on/off enable toggle for a feature/function | — |
energy_charge |
number | Energy delivered during a charge session | kWh charged this session |
fan_mode |
enum | The fan's operating mode | auto / manual / sleep |
fan_speed |
number | The fan's speed setting | Numeric or step level |
flow_rate |
number | Liquid/water flow rate | L/min |
grid_consumption |
number | Power/energy drawn from the utility grid | — |
heater_relay_status |
boolean | On/off status of a heater's relay/output | — |
house_consumption |
number | Total household/site power consumption | — |
humidity |
number | Legacy alias of current_humidity, kept for backward compatibility |
Prefer current_humidity in new integrations |
last_precipitation |
number | Most recent recorded precipitation reading/timestamp | Weather-station rain gauge |
max_charge |
number | Configured maximum charge limit | Max SOC % or max charge power |
modbus_id |
number | The Modbus slave/unit ID address used to reach this device on the RS485 bus | Dynamic Modbus ID field required by every MODBUS package (see Requirements) |
open |
button | Command to open an actuator | Open a valve, cover, or gate |
position |
number | A numeric position value | Valve or cover position, in % |
power |
number | Generic instantaneous power reading | Watts |
ppm |
number | A parts-per-million concentration reading | CO2 / air-quality sensor |
pv_consumption |
number | Power/energy consumed that is sourced from a PV (solar) system | — |
start_charging |
button | Command to begin a charging session | — |
status |
text | General device status/health information | Not tied to device-specific business logic |
stop |
button | Generic stop command | — |
switch |
boolean | A generic on/off switch component | — |
target_humidity |
number | The desired/setpoint humidity level | — |
target_temperature |
number | The desired/setpoint temperature level | — |
thermostat_mode |
enum | The thermostat's operating mode | heat / cool / auto / off |
time_charge |
TBD | Meaning not yet finalized — needs a definition before use | — |
total_active_energy |
number | Cumulative active energy (standard electrical metering term) | kWh |
total_charge |
number | Cumulative (lifetime) energy charged into the battery | — |
total_current |
number | Total/aggregated current reading | e.g. summed across phases |
total_power |
number | Total/aggregated power reading | e.g. summed across phases or sources |
water_consumption |
number | Cumulative water usage | — |
water_pressure |
number | Water pressure reading | — |
water_temperature |
number | Water temperature reading | — |
work_state |
text | The device's operational state, tied to its core business logic | idle / heating / cooling / charging / discharging |
working_mode |
enum | The mode the device is currently operating in, usually user- or schedule-selected | manual / auto / eco / boost |
status, work_state, and working_mode are related but distinct: status is general device health/info, work_state reflects the device's business-logic-driven operational state, and working_mode reflects how the device is configured to behave.
This set is not closed — new roles can be added as new integrations require them.