This repository hosts application packages and integrations for the Shelly Power Dongle (SPD), targeting CAN and RS485 devices.

Requirements

Every package developed for a MODBUS device in this repository must follow these requirements:

  1. Dynamic Modbus ID Virtual Component. The device's Modbus slave/unit ID must never be hardcoded into the script logic — it must be exposed as a number Virtual Component so it can be reconfigured from the Shelly app without redeploying code, following the pattern established in pkgs/marstek/venus_e/revision/app.shelly.js:
    • Component config: min: 1, max: 247 (the valid Modbus unit-ID range), persisted: true (survives reboot), meta.ui.view: "field" — a precise numeric text-entry input, not "slider", since being off by even one value breaks communication with the device entirely.
    • A getSlaveId()-style helper reads the component's live value on every request (not just once at script init), clamps/rounds it into the valid range, and syncs the clamped value back to the component if it was out of range — mirroring how getControlPower() handles the Control Power component in the same script.
    • Every MODBUS frame-building function (both read and write) must call this helper for the unit-ID byte, instead of referencing a static config constant.
    • This component's mapping.json entry must carry the modbus_id role (see Roles below).

This set of requirements is not closed — more will be added as new packages establish new conventions.

Roles

Each Virtual Component entry in a package's mapping.json carries a role field — a standardized tag describing what the component semantically represents (independent of its device-specific key/name). This lets tooling reason about components generically across different vendor integrations (e.g. any component tagged battery_level means the same thing regardless of which package defines it).

The currently defined roles are:

Role Data type Description Example use case
auto_balancing boolean Whether automatic (e.g. cell/load) balancing is enabled Battery pack auto cell-balancing toggle
auto_start boolean Whether the device automatically starts/resumes operation Generator or pump auto-start enable
average_temperature number An averaged temperature reading across multiple sensors Average of several battery cell temperatures
backlight_enable boolean Toggle for a display's backlight Thermostat screen backlight on/off
battery_consumption number Power/energy drawn from the battery Instantaneous discharge power
battery_level number Battery state of charge SOC, in %
battery_power number Instantaneous battery power, bidirectional (positive = discharge, negative = charge) Marstek Pbat-style live power reading
battery_state text The battery's current operating state charging / discharging / idle / fault
brightness number A numeric brightness/dimming level Display or light brightness, in %
charge_command enum A command that triggers a charge/discharge/stop action (not a passive mode readback) Marstek ChgCmd-style dropdown: Stop / Force Charge / Discharge
charged boolean Boolean flag: battery/device is fully charged —
charging_power number The power setpoint applied on the next charge or discharge command (bidirectional use, despite the name) Marstek ChgPowerSet-style control power field
close button Command to close an actuator Close a valve, cover, or gate
curr_temperature number Deprecated — legacy alias of current_temperature; use that instead —
current number Electrical current reading Amps
current_humidity number The current/live relative humidity reading —
current_limit number A configured maximum current limit Charge current cap
current_temperature number The current/live temperature reading (preferred over curr_temperature) —
enable boolean Generic on/off enable toggle for a feature/function —
energy_charge number Energy delivered during a charge session kWh charged this session
fan_mode enum The fan's operating mode auto / manual / sleep
fan_speed number The fan's speed setting Numeric or step level
flow_rate number Liquid/water flow rate L/min
grid_consumption number Power/energy drawn from the utility grid —
heater_relay_status boolean On/off status of a heater's relay/output —
house_consumption number Total household/site power consumption —
humidity number Legacy alias of current_humidity, kept for backward compatibility Prefer current_humidity in new integrations
last_precipitation number Most recent recorded precipitation reading/timestamp Weather-station rain gauge
max_charge number Configured maximum charge limit Max SOC % or max charge power
modbus_id number The Modbus slave/unit ID address used to reach this device on the RS485 bus Dynamic Modbus ID field required by every MODBUS package (see Requirements)
open button Command to open an actuator Open a valve, cover, or gate
position number A numeric position value Valve or cover position, in %
power number Generic instantaneous power reading Watts
ppm number A parts-per-million concentration reading CO2 / air-quality sensor
pv_consumption number Power/energy consumed that is sourced from a PV (solar) system —
start_charging button Command to begin a charging session —
status text General device status/health information Not tied to device-specific business logic
stop button Generic stop command —
switch boolean A generic on/off switch component —
target_humidity number The desired/setpoint humidity level —
target_temperature number The desired/setpoint temperature level —
thermostat_mode enum The thermostat's operating mode heat / cool / auto / off
time_charge TBD Meaning not yet finalized — needs a definition before use —
total_active_energy number Cumulative active energy (standard electrical metering term) kWh
total_charge number Cumulative (lifetime) energy charged into the battery —
total_current number Total/aggregated current reading e.g. summed across phases
total_power number Total/aggregated power reading e.g. summed across phases or sources
water_consumption number Cumulative water usage —
water_pressure number Water pressure reading —
water_temperature number Water temperature reading —
work_state text The device's operational state, tied to its core business logic idle / heating / cooling / charging / discharging
working_mode enum The mode the device is currently operating in, usually user- or schedule-selected manual / auto / eco / boost

status, work_state, and working_mode are related but distinct: status is general device health/info, work_state reflects the device's business-logic-driven operational state, and working_mode reflects how the device is configured to behave.

This set is not closed — new roles can be added as new integrations require them.

Contributing

Contributions are welcome — see CONTRIBUTING.md for contribution terms and guidelines.

License

Licensed under the Apache License 2.0.

About

No description, website, or topics provided.

Resources

Contributing

Stars

0 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages