Under the project IPIN there is an initiative to visualize the energy flows within the EUREF MSG.
For the online visualization, the availability of real-time data is needed. One possible way would be to have a JSON text file available every 10 minutes in a URL accessible to the visualization system.
Initially (in the test phase), only the variables listed under are going to be displayed. The plan is to extend the project to cover all the information available in the MSG in the middle term.
“SE DB ID” refers to the Database ID of the table tbLoggedEntities located in the database StruxureWareReportsDB.
| Object | Internal ID | Path | Schneider-DB ID |
|---|---|---|---|
| WEA_Haus1 | 1 & 2 | /MicroSmartGrid/Modbus Interface/Zähler 17 (WEA Haus 1)/Wirkleistung PSumme Erweiteter Trendlog | 403 |
| WEA_Haus4 | 3 & 5 | /MicroSmartGrid/Modbus Interface/Zähler 02 (WEA Haus 4)/Wirkleistung PSumme Erweiteter Trendlog | 64 |
| PVA_Haus4 | 15 | /MicroSmartGrid/Modbus Interface/Zähler 03 (PVA Haus 4)/Wirkleistung PSumme Erweiteter Trendlog | 365 |
| PVA_Haus8 | 11 | /MicroSmartGrid/Modbus Interface/Zähler 05 (PVA Haus 8)/Wirkleistung PSumme Erweiteter Trendlog | 355 |
17 charging stations + 2 batteries
| Object | Internal ID | Path | Schneider-DB ID |
|---|---|---|---|
| L_EnergyParken_11 | - | /MicroSmartGrid/Modbus Interface/Zähler 11 (Ladesäule Energie + Parken)/Wirkleistung PSumme Extended Trend Log | 5 |
| L_RweSchnell_12 | - | /MicroSmartGrid/Modbus Interface/Zähler 12 (Ladesäule RWE Schnellladesäule)/Wirkleistung PSumme Extended Trend Log | 6 |
| L_SchneiderEU_13 | - | /MicroSmartGrid/Modbus Interface/Zähler 13 (Ladesäule Schneider Electric + Ubitricity)/Wirkleistung PSumme Extended Trend Log | 8 |
| L_Db_14 | - | /MicroSmartGrid/Modbus Interface/Zähler 14 (Ladesäule DB)/Wirkleistung PSumme Extended Trend Log | 10 |
| L_Mini_15 | - | /MicroSmartGrid/Modbus Interface/Zähler 15 (Ladesäule E-Mini)/Wirkleistung PSumme Extended Trend Log | 12 |
| L_WallboxPlattform_16 | - | /MicroSmartGrid/Modbus Interface/Zähler 16 (Wallboxen Plattform Messelbau)/Wirkleistung PSumme Extended Trend Log | 14 |
| L_Dai_26 | - | /MicroSmartGrid/Modbus Interface/Zähler 26 (DAI)/04_Trend/ME_Wirkleistung°26_Extended Trend Log | 344 |
| L_DbCombi_27 | - | /MicroSmartGrid/Modbus Interface/Zähler 27 (DB-Combi)/04_Trend/ME_Wirkleistung_Extended Trend Log | 346 |
| L_RweSS_28 | - | /MicroSmartGrid/Modbus Interface/Zähler 28 (RWE_SS)/04_Trend/ME_Wirkleistung_Extended Trend Log | 348 |
| L_Vattenfall_29 | - | /MicroSmartGrid/Modbus Interface/Zähler 29 (Vattenfall)/04_Trend/ME_Wirkleistung_Extended Trend Log | 350 |
| L_Ebee_6 | - | /MicroSmartGrid/Modbus Interface/Zähler 06 (EBEE)/Wirkleistung PSumme Erweiteter Trendlog | 353 |
| Lead_Battery | 12 | /MicroSmartGrid/Modbus Interface/Zähler 08 (Batterie)/Wirkleistung PSumme Erweiteter Trendlog | 68 |
| LiIon_Battery | - | /MicroSmartGrid/Modbus TCP Network/Lithium_Ion_Battery/04_Trend/ME_Wirkeistung Erweiteter Trendlog | 294 |
| Object | Internal ID | Path | Schneider-DB ID |
|---|---|---|---|
| NetCon | 16 | /MicroSmartGrid/Modbus Interface/Schnittstelle 21 (Hauptzähler)/Wirkleistung_Extended Trend Log | 440 |
{
"Time": "2013-08-02 14:24",
"WEA_Haus1": 0.11,
"WEA_Haus4": 0.12,
"PVA_Haus4": 15.716,
"PVA_Haus8": 13.777,
"L_EnergyParken_11": 0.000,
"L_RweSchnell_12": 0.000,
"L_SchneiderEU_13": 0.000,
"L_Db_14": 0.000,
"L_Mini_15": 0.000,
"L_WallboxPlattform_16": 0.000,
"L_Dai_26": 0.000,
"L_DbCombi_27": 0.000,
"L_RweSS_28": 0.000,
"L_Vattenfall_29": 0.000,
"L_Ebee_6": 0.000,
"Lead_Battery": 0.000,
"LiIon_Battery": 0.000,
"NetCon":0.000
}