OpenECraft is extended through the openecraft-api crate. A plugin adds

Extension What it is Editor Command line / MCP
Command function on the project with typed parameters, returns JSON Plugin commands pane (Plugins tab: every command by plugin with a search; favorites, recently used commands and a menu per external plugin on the tab; a form for the parameters) and the command search a command / tool of its own
Check adds issues to the project check Messages pane check
Report table generated from the project Reports pane, report pages and report blocks report --kind <name>
Exporter file generated from the project File › Export export --format <name>

Names are snake_case and unique among all plugins; commands must not take the name of a built-in tool. Changes a command makes to the project are one undo step. openecraft-cli plugins lists the loaded plugins, Tools › Manage plugins in the editor enables and disables them (remembered by the editor).

In Plugins › Manage plugins, enter a plugin folder containing plugin.json, or a parent folder whose subfolders contain plugins, and click Load plugins. The editor loads them for the current session and remembers usable folders for later launches. A failed sibling plugin does not prevent remembering plugins that loaded. OPENECRAFT_PLUGINS remains available for environment-based configuration.

Rust plugins

Built-in plugins live in crates/openecraft-api/src/builtin.rs and its submodules and are compiled into every front end (also the web version): the project checks, reports and exports of openecraft-core, project statistics, panel layout checks, panel manufacturing, part lifecycle, and one plugin per area of project commands (pages, sheets, drawing, device boxes, devices, plugs, PLC, potentials, process engineering, single-line diagrams, tables, engineering, electrical engineering, panel layout, rooms, buildings, 19-inch racks, routing, field wiring, wiring, harnesses, integration, languages, structure, properties, configurator, report blocks, project management). An area lists its commands in a COMMANDS table of Specs (builtin/<area>.rs); the command line and the MCP server offer them as tools next to the session tools of cli/. The project checks themselves are registry entries of openecraft_core::checks (one Check per area, with a snake_case name), and the registry kinds, parameters and tables are defined in openecraft_core::{ext, params, table}. A plugin implements Plugin:

use openecraft_api::{param, Info, Kind, Plugin, Registry, Table, Text};
use openecraft_core::issue::{Issue, Severity};
use openecraft_i18n::tr_const;

pub struct Spares;

impl Plugin for Spares {
    fn info(&self) -> Info {
        Info { id: "spares".into(), name: Text::Borrowed(tr_const!("Spare parts")), version: "1.0".into(), description: Text::Borrowed("") }
    }

    fn register(&self, reg: &mut Registry) -> Result<(), String> {
        reg.command("set_spares", tr_const!("Sets the spare quantity of a part"), vec![param("number", Kind::Str, tr_const!("Part number"))], |prj, args| {
            // change `prj`, return JSON
            Ok(serde_json::json!({ "part": args.req("number") }))
        })
        .check("spares_missing", tr_const!("Spare parts"), |prj, analysis| Ok(vec![Issue::plain(Severity::Info, "nothing missing", None)]))
        .report("spares", tr_const!("Spare parts"), |prj, analysis| Ok(Table::new([tr_const!("Part")])))
        .exporter("spares_csv", tr_const!("Spare parts (CSV)"), "csv", |prj| Ok(String::new()));
        Ok(())
    }
}

Texts given as &'static str are English catalog entries (tr_const!, see AGENTS.md) and are shown translated. Issues of a check carry either a finished text (Issue::plain) or, like the built-in checks, a catalog entry with its arguments (openecraft_core::issue!(Severity::Warning, target, "Cable {} defined {} times", tag, n)), which Issue::message() renders in the current language; the check tool reports the template as key next to the message.

External plugins

An external plugin is a program in any language in a folder of its own:

my_plugin/
  plugin.json
  main.py
{
  "id": "my_plugin",
  "name": "My plugin",
  "version": "1.0",
  "description": "What it does",
  "api": 1,
  "run": ["python3", "main.py"]
}

The folders containing plugin folders are given in the environment variable OPENECRAFT_PLUGINS (separated like PATH) for the editor and the command line, or with openecraft-cli --plugins <folder>. External plugins need processes and are not available in the browser.

Protocol

For every request OpenECraft starts the program (run, in the plugin folder), writes one JSON object to its stdin and reads one JSON object from its stdout, both in UTF-8 (Python is started with PYTHONUTF8=1 and PYTHONIOENCODING=utf-8; where python3 is not installed, as on Windows, python is started instead). Every request has "api": 1 and a method. An answer {"error": "message"} (or a non-zero exit code, with the message on stderr) is an error. project is the project as in a .oec file. A program that has not answered after 5 minutes is stopped and the request fails. Plugins run with the rights of the user: load only plugin folders you trust.

Requests also include project_features, an array advertising model support in the running host (PROJECT_FEATURES in openecraft-api); each is described with the data it concerns, for example directional_pin_contacts, explicit_wire_junctions, directed_junction_paths, fluid_port_roles, wire_hide_labels and scoped_connections. Importers can require features before returning a changed project; using a separate updated CLI does not give an older editor these features.

Request Answer
{"method": "describe"} {"commands": [{"name", "help", "params": [{"name", "kind", "required", "help"}]}], "checks": [{"name", "title"}], "reports": [{"name", "title"}], "exporters": [{"name", "title", "extension", "params"}]} (all lists optional, params of exporters too)
{"method": "command", "name", "params": {…}, "project": {…}} {"result": <any JSON>, "project": {…}} – project only if the command changed it
{"method": "check", "name", "project"} {"issues": [{"severity": "error" | "warning" | "info", "message", "page": <page index>, "item": <item id>}]} – page / item optional; page alone points at the page, a page the project does not have at nothing
{"method": "report", "name", "project"} {"headers": ["…"], "rows": [["…"]]}
{"method": "export", "name", "params": {…}, "project"} {"content": "file content"} (text; params holds what the front end passed: by convention page, the name of one page, and file, the file name)

Parameter kinds: str, int, num, bool, ids (list of item ids), points (list of [x, y] in mm), object (JSON object). required defaults to true.

A command that answers with an error leaves the project unchanged, also in the editor and the MCP server.

describe is asked once when the plugin is loaded; checks run after every change of the project in the editor, so they should answer quickly. The project's check settings apply to the issues of plugins as well: a check can be switched off by its name, and its plain messages share the check's name as code (level changes then apply to all of them) and can be accepted one by one.

Parts may set symbol to the key of a project symbol definition. The shared part placement logic uses that definition in the editor, CLI and MCP. An empty key keeps the existing template-based selection. source_data on parts and symbol definitions can retain importer identifiers and vendor properties as JSON. Project.import_sources maps stable source IDs to JSON datasets, including records that have no native editing surface. These fields are optional for older files.

Portable native macro clips may carry symbol_defs, an array of project symbol definitions. Inserting a clip installs missing definitions and renames conflicting incoming keys, preserving local edits and updating the incoming instances. The optional devices map and parts array carry device assignments and catalog records. Insertion renames device assignments with their instances and installs missing parts without overwriting local catalog records. Part.symbol follows renamed definitions. Macro previews resolve bundled definitions before consulting the destination project. The insert_macro command accepts a native macro as a JSON string plus page, x and y. The editor, CLI and MCP expose the same command. Large CLI parameter objects can be supplied as --json @parameters.json to avoid shell argument limits. User symbol pins may set internal: true for jumper attachment nodes. They still participate in local bridges but do not appear as physical device endpoints. A wire passing through an internal pin connects to it; other pins need a wire end there. list_nets exposes native membership by symbol ID and zero-based pin index; its pins array contains physical device endpoints. The additional connection_points array includes junction and internal bridge attachment points that belong to a wired or physical net, without adding device endpoints or empty nets. Importers can verify paths ending at these points through the same command in the editor, CLI and MCP. bridge_terminals defaults to true and can be disabled for individual wire runs. list_connections returns physical pin-to-pin wire targets as from and to objects containing a symbol ID and zero-based pin index, together with the potential, conductor number, color, cross section, cable and core. Internal device bridges retain electrical continuity without creating external manufacturing wires. User junction symbols may set directed_junction: true: their bridges then also describe physical target paths between spaced ports. set_symbol_junction_paths accepts a symbol key and paths: {"links": [[0, 1], [0, 2]], "directed": true}; the symbol editor exposes the same paths. The page property page.use_drawn_wire_targets preserves explicit branches at device connection points and traces wires through the internal bridges of devices. On such pages and on pages with explicit junctions, pins of one symbol at the same position count as one attachment. User symbols can supply pin_directions, a map from zero-based pin indices to local direction masks (up 1, right 2, down 4, left 8). Omitted entries allow every side; zero disables automatic side contacts. Directions follow instance rotation and mirroring. Saved wire endpoints always connect. set_pin_connection_directions accepts symbol, pin and directions ("up,right", "all" or "none"); the symbol editor exposes the same directions. New automatic wires use these directions. The page property page.explicit_wire_junctions makes endpoint-to-interior crossings nonconductive unless a junction connects them, and device ports connect only to authored wire endpoints. Internal rail attachments and junction ports retain side contacts. Junction dots and open-end checks use the same rules. device_box_roles adds SymbolInst.box_role to device boxes: extension adds connection points to the device of the box's tag, view shows connection points it already has and connects them across pages by device and designation; the default device is left out of the file. An interruption instance can store function.connection_scope in its values. Points connect and cross-reference only others with the same scope and label; an empty scope retains the existing project-wide behavior. The label stays the displayed name. This property is editable through the property database in the editor and the shared CLI/MCP property commands. User symbols can supply fluid_ports, a map from zero-based pin indices to supply, pressure, working, exhaust, return, pilot, suction, leakage, measuring or passage. An omitted entry keeps designation-based inference. These roles survive library copies, portable macros and project serialization; list_symbols exposes them and set_fluid_port_role edits or clears an entry (role: "automatic") through the editor's Plugins pane, CLI and MCP. The symbol editor also offers the role on the selected fluid connection point. FieldKind::TagName displays the device name without inherited structure while remaining linked to the instance tag. Plot frames can set visible: false when imported artwork includes its own border and title block; paper geometry remains available. ZeroBasedNumbers is supported for source drawing column labels. PNG drawing images, including palette images and transparency, export to PDF with an image soft mask. Func::Graphic keeps decorative artwork outside device identification and netlist evaluation while retaining editable symbol primitives.

Project symbol definitions can contain an Image drawing primitive. It carries a file name, base64 encoded data, and four corners in local symbol coordinates, ordered top left, top right, bottom right, bottom left. The editor and SVG/PDF output apply the symbol's rotation and mirror to these corners. Existing drawing primitive representations are supported alongside images.

User symbols can specify a domain of Electrical, Fluid, or Process. Older symbol files default to Electrical. Fluid and process connection points participate in fluid nets, and connecting them to an electrical pin is reported as a mixed net.

Field primitives accept an optional angle in degrees using the same convention as symbol text. Omitting it keeps the historical horizontal-label behavior. Their kind can also be {"Pin": 0} (zero-based pin index), which follows the placed instance's connection designation. A terminal's displayed designation uses Label.

The Auxiliary function represents an additional device function with electrical pins and a cross-reference to its main function, without inventing a contact type. Junction has no device tag and connects only the paths listed in its bridges. Its connection points are local routing nodes and are excluded from device endpoints in the netlist.

Wires can set hide_labels: true when their wire numbers and cable/core labels are already drawn as separate annotations. Electrical properties and reports stay available. The wire properties panel and update_wire command can restore the automatic labels; new wires show labels by default.

A complete example is in examples/plugins/page_notes.

CAD drawing coordinates

The CLI/MCP import_dxf and import_dwg tools return source_bounds (min and max points in decoded drawing millimetres, Y up) and page_origin (the page position of the source top-left bound), alongside scale. For an imported page point p, its source coordinates are source_bounds.min.x + (p.x - page_origin.x) / scale and source_bounds.max.y - (p.y - page_origin.y) / scale. This includes the drawing's unit conversion and permits external importers to apply an authored viewport. Existing page placement and parameter defaults remain unchanged.

EPLAN window macros

The drawing plugin accepts PXF window macro XML with import_ema (parameter xml). Its result lists native symbol definitions, function types, variant IDs, multi-device macros, and unresolved references. Reimport preserves locally edited definitions. The place_part command accepts an optional variant symbol key. The CLI and MCP file tool import_eplan_symbols reads an EMA, an EDZ, a companion article XML, or a vendor folder with a selected part number.

product_designation_fields advertises Prim::Field kind {"Product":N}. It displays the final N product designation levels of the current instance tag, excluding function and location aspects; zero behaves as one. The field updates after renaming and survives symbol-library and project serialization. The symbol editor exposes the level count; plugins use the same serialized primitive through symbol definitions. Hosts without this feature cannot load these field variants.

function_text_fields advertises Prim::Field kind "FunctionText" and the optional user-symbol default_function_text. Shared placement initializes the native instance function text from the library default. Fields render the current instance value, including transformed multiline text; the automatic tag block omits a duplicate function text when an explicit field exists. list_symbols returns the library default.

function_part_selection advertises function-specific assigned-part references. The function.part_index property selects a one-based position in the device parts and records its part number in SymbolInst.values["function.part_number"]. Removing earlier parts does not change this reference. A removed selected part yields an empty selection, position zero, and a project issue; setting an existing position repairs it, while clearing the position resets automatic first-part selection. part.* properties on a function read only its selected part; device properties retain their aggregate behavior. function.manufacturer supports an explicit editable override with selected-part fallback, and function.selection_text retains authored selection text independently of catalog type numbers. The registered list_function_parts command returns every function’s selected part and editable attribute values for batch inspection.

property_blocks advertises Prim::PropertyBlock with ordered Property(key), Field(FieldKind) and Text(value) rows, local pos and step vectors, font size, horizontal anchor, text angle, align (Start, Middle, End) and optional RGB color. The shared canvas/export renderer resolves properties on the original full-tagged function, skips empty values, and flows every line before applying symbol transforms. User-symbol default_values initializes editable instance properties during shared placement; list_symbols exposes defaults and blocks. The symbol editor supports creation and editing of blocks and default properties.

The wire_type project feature preserves conductor construction on Wire.wire_type. update_wire accepts wire_type; list_connections returns it for each physical connection. The editable connections table appends Wire type after its original nine columns; connection reports include the same value. Empty means unspecified.

The physical_wire_routes feature advertises contact-aware conductor tracing. list_connections includes route_traced and wires (native page ID and wire ID). When route_traced is false, the wire list is the existing net-wide property scope, not a demonstrated point-to-point path. Explicit-junction pages keep wire-local vertices separate until a valid endpoint, junction or directional pin contact joins them. These rules also apply when a crossing belongs to one net by another route.

trace_wire_routes accepts routes: {"pairs": [{"from": {"symbol": 12, "pin": 0}, "to": {"symbol": 34, "pin": 0}}]} and returns an ordered result for each pair. It traces exact local drawn endpoints, including virtual interruption points, without jumping between equal potential or interruption names. Each result has route_traced and wires with native page/segment IDs and their conductor properties. This verifies a particular branch even when the physical wiring list chooses another valid path through a named net. An invalid or disconnected endpoint has no traced route.

Complete PLC module channels

The multi_channel_plc project feature advertises UserSymbol.plc_channels, also exposed by list_symbols. Each channel definition contains a stable key, zero-based directional index, optional input direction, analog, data_type, designation, zero-based physical pins, and an optional signal_pin. Existing single-channel plc_channel metadata remains supported.

Channel instance values use one-based property keys function.plc_address[1], function.plc_symbol[1], function.plc_comment[1], and function.plc_data_type[1]. Library definitions should leave configured addresses and signal names empty. Property blocks can reference these keys to display current configuration. get_plc_points returns a row per channel with its physical pin indices; set_plc_channel edits one channel using a symbol ID and a zero-based channel index. PLC table row keys use symbol_id:channel_index for complete modules and retain numeric symbol IDs for legacy single points. Blank and directionless channels are excluded from PLC tag exports.

Linked PLC channel representations

The linked_plc_channels feature adds SymbolInst.plc_bindings, a map from zero-based channel indices to {group, primary}. A nonempty group identifies the same logical channel across representations with the same full device tag. Set primary on the electrical representation whose physical pins and location should be used for I/O navigation. Different full device tags keep copied devices independent.

The PLC overview, hardware counts, tables and tag exports use logical channels. Channel edits, indexed channel property edits, card readdressing and symbol-table import update all linked views; a released view rejects the whole channel edit. Existing authored values remain stored on each view. Empty displayed fields can fall back to another linked view. get_plc_points returns logical I/O rows by default; representations:true returns all schematic representations with their own stored values, physical pin indices and binding metadata for lossless import verification.

The plc_channel_indices feature adds optional ChannelBinding.index, the card-relative hardware channel number. Store the module overview's hardware number on every linked view, even when an electrical view contains only one local channel. get_plc_points.hardware_index exposes this number separately from the symbol-local channel index used by set_plc_channel. Readdressing and the logical channel designation use the hardware number. Older bindings without an explicit number fall back to the most complete linked module definition, keeping continued projects usable after sheet reordering.

Parts representing complete PLC modules use one FunctionTemplate per channel, with PlcInput, PlcOutput, PlcAnalogInput or PlcAnalogOutput and that channel's physical pin designations. Leave reusable signal descriptions empty. Native function usage and reserve calculations count linked schematic channels once and exclude cabinet graphics. list_device_descriptions includes analog function capacities; list_unplaced recognizes occupied module channels by hardware identity independently of configured address text.

set_plc_card preserves authored channel addresses for metadata-only changes. Supplying start_byte, output_byte, readdress:true, or a Rockwell slot rebuilds addresses from configuration. An imported head description with empty ports and no configured bus keeps an empty port list; it does not acquire an inferred PROFINET interface.

Station scheme conversion includes complete-module digital channels and their linked representations. It retains each configured address offset and signal name. Custom address text that is not a supported digital address remains unchanged.

The explicit_panel_mounts feature supports EnclosureKind::Assembly, an open mounting canvas without implicit shell or plate geometry, and ItemKind::MountingPlate, an explicit item with authored position, size and thickness. Explicit plate items also suppress the default plate of a cabinet. Coordinates remain in the enclosure's common frame. PanelItem.mounted_on references another item in the same enclosure; mounting_explicit:true distinguishes an explicitly free item from legacy inferred rail placement. rail_mount_override:true retains the instance datum through native loading and part refresh. rail_vertical:true measures the cross-rail datum along x instead of y.

Use add_enclosure / set_enclosure with assembly:true, place_mounting_plate, and set_panel_item with mounted_on, dimensions, rail_offset, clip_on, rail_vertical and rail_mount_override. Parent moves and depth changes carry descendants once, including nested supports. Explicitly detached items keep their position. Item lists expose the mounting fields. Portable and pattern copies remap internal mounting references; deleting a support detaches surviving children. Both horizontal and vertical rails support snapping and arrangement. Original project data without these optional fields retains legacy behavior.

The individual_panel_terminals feature adds PanelItem.terminal: a nonempty designation binds a footprint and its own part to one terminal of a strip. Empty retains whole-strip layout. Physical points, meshes, virtual wiring and 3D cable endpoints resolve each terminal separately; ambiguous repeated placements do not select an arbitrary item. Function-specific selected parts also drive terminal strip layout. place_panel_device creates an explicitly dimensioned device or terminal; set_panel_item can edit its terminal designation. get_panel_points exposes generated or exact physical points through the shared API.

The explicit_panel_geometry feature retains PanelItem.single_part: the footprint represents only its own catalog part even with no terminal designation. Missing catalog dimensions can generate non-exact connection points using the instance footprint, without rewriting the catalog. Multiple physical views resolve by selected article only when unique. Enclosure.no_implicit_plate suppresses the default plate, while mounting_origin: [x,y,z] gives an explicit mounting-face datum in enclosure coordinates. Open assemblies default to the zero datum and full canvas extent; their routing spaces have no cabinet walls. The add/set enclosure commands expose implicit_plate, mounting_origin (object with x/y/z; empty resets) mounting_size (object with width/height for a plate that is not centred; empty resets) and door_hinge (left or right, the edge the door is hinged at seen from the front), and device placement/edit commands expose single_part. Explicit plates contribute their own part to the material list.

The cached_impossible_routes feature adds layout.routing.reuse_failed_searches (default false), also exposed by the routing_rules command. A project can explicitly retain impossible ahead-search results after channel fill changes instead of repeating exhaustive searches. Ordinary projects keep the existing retry behavior. Successful cached routes still require capacity and clearance checks.

The literal_part_quantities feature adds PartRef.total. A true value makes count the literal quantity for the whole device/strip (including an explicit zero), instead of multiplying terminal articles by strip positions. The default false preserves legacy counting, including the legacy zero-as-one default. Primary automatic and additional literal references may use the same article number; their quantities add, so newly drawn terminals still increase primary material without multiplying spares. Literal material-only devices also appear in list_devices and the BOM. The shared add_device_part and set_device_part_quantity commands expose both count and mode; the latter uses a 1-based assignment index. The device parts editor also exposes the total quantity flag. Zero literal references contribute no function capacity, pieces, weight, heat loss or material quantity.

Enclosure.device_tag binds a physical body to its primary device assignment, like the tag on a structural panel item. Their primary automatic article is counted by the physical layout, with additional literal articles counted separately. Changing the physical article through set_enclosure, set_panel_item or profile replacement updates its primary assignment and function part bindings while retaining literal spares. Add/set enclosure commands expose device_tag; item edits expose part.

The material_ownership feature adds owner_device and bom_excluded to panel items and enclosures, exposed by the panel query and editing commands. Ownership records the device accounting for an article and never changes mounted_on. A placement exclusion suppresses only its physical material entry; the editable device properties device.material_owner and device.exclude_from_bom retain material-only devices and can suppress all material assigned to a device. Ownership references follow device renaming. Reusable panel macros clear external owner tags and retain explicit placement exclusion. Panel queries expose mounting_height above the explicit support (null if unknown); generated standoffs of rails on an explicit support use that height and require layout.hardware, rather than treating the support thickness as a spacer.

Cabinet device bindings also participate in list_devices and the material list when no schematic function is drawn, independently of any additional articles. An individually placed terminal not yet represented in the schematic contributes its primary part once per terminal designation. Repeated physical views and newly drawing the same terminal do not add another piece. Existing whole-strip placement keeps its schematic terminal expansion.

The portable_macro_materials feature guarantees that portable macro insertion preserves device property values and distinct automatic and literal references to the same article, including zero. When extending an existing device, missing reference modes and properties are filled while local quantities and property values remain unchanged. Articles the device does not use are added only when it has none yet or when a function of the clip selects them, unless explicitly opted in below. Material owners within a clip follow target page structure and collision renaming; external owners are cleared. Incoming device tags are reserved before allocating replacements, including material-only existing tags. Conductive auxiliary views follow their master tag. Device property placeholders resolve together with macro tags and part numbers.

The explicit_macro_part_additions feature adds optional Clip.device_part_additions, a map of device tags to article-number arrays. It explicitly requests adding missing literal accessory references already present in the clip's matching devices[tag].parts. It cannot add an unassigned article or an automatic reference, replace an existing article, or overwrite a local quantity. Without this map, paste and macro insertion keep the existing-device rules above. Tags and numbers support macro parameters, target structure and collision renaming. This is insertion intent, not an instruction to change the project's ordinary copy/paste defaults.

The per_wire_junctions feature adds optional Wire.explicit_junctions: omitted inherits page.explicit_wire_junctions, true requires authored junction contacts, and false permits implicit T contacts. Implicit wire-to-interior joins require both conductors to permit them; explicit junctions and saved endpoints still connect. Pin-side attachments use the individual conductor policy. An explicit wire also enables drawn physical targets on its electrical net. The shared add_wire, connect, route and update_wire commands accept junction_policy: inherit|explicit|implicit. update_wire returns that policy; page queries and portable clips retain the optional native field. The editor offers the same choices in wire properties. Inserting an explicit macro never changes the page setting or other wires. Scan caching tracks policy edits, and wire cleanup and collinear merging preserve different policies and properties.

apply_cable_part (cable, part) applies a project or built-in catalog part to an existing cable. It uses the same operation as the editor, including type, supplied core names and cross-section, and Outer diameter from technical data in millimetres. Missing or invalid diameters reset the override to zero so routing uses its estimate. It returns the configured cable fields and diameter_mm (zero means estimated), and rejects unknown cable or part names without changing state.

list_cable_parts takes no parameters and returns the available cable articles from project parts and the built-in catalog, sorted by number and without duplicates. Project definitions take precedence, including a local change of product group. Rows include number, type, description, manufacturer, supplied cores and cross-section, and a positive declared diameter_mm or null. The editor uses the same precedence with its configured parts database.

The portable_cables feature carries cable inventories and their referenced local parts in Clip.cables. Copy/paste and macro insertion allocate fresh cable IDs and collision-free tags in the destination structure, consistently remapping marker symbols, wires, connection definitions and cable definition lines. Core assignments are retained only for cables owned by the clip. Legacy clips without cable definitions continue to clear wire/core references. Cable text fields also support native macro placeholders. This behavior is shared by all frontends.

An explicit function article reference can resolve the matching cable article when the same tag also has an ordinary device material record. The selected article must match an actual assignment; unknown references remain invalid. Cable material stays in the cable inventory rather than being duplicated in the ordinary device bill of materials.

Physical connection results can contain the same endpoint pair more than once when separate cable cores have distinct simple drawn routes. Each connection retains its own wire IDs and cable/core properties for reports and routing. A dangling spur is not treated as an additional complete connection. The existing connection commands and report registry expose this behavior in every frontend.

The shared apply_cable_part command updates explicit placed-function references that belonged only to the previous cable article. References to an ordinary device article under the same tag, and invalid or unrelated explicit references, are preserved. The cable editor uses the same core reference operation for catalog selection and direct part-number edits. Length and conductor assignments are retained when applying catalog cable data.

The macro_definition_parameters host feature extends native macro placeholders to portable symbol definition letters, default labels/function texts/properties, pin labels, text primitives and literal attribute-block rows. Symbol keys, property keys, encoded images and raw source metadata retain their identity. Resolution operates on a clip copy before installation and is shared by desktop, CLI and MCP. Importers converting source template parameters should require this feature so older hosts do not leave static graphics inconsistent with resolved instances.

insert_macro accepts optional values, an object mapping placeholder names to strings. It resolves instance and portable definition fields together before paste; unknown placeholders stay literal. Invalid non-string values fail before any edit. Omitting the parameter preserves existing unresolved template text. This option is available through the shared registry in every frontend.

The parallel_cable_cores host feature confirms that physical connection consumers retain distinct authored parallel core routes. Importers must check the running host as well as any separate verification CLI before accepting circuits containing assigned cable cores; a newer verifier cannot update an older editor's report engine.

The page_property_blocks feature resolves project/page properties in symbol attribute blocks using their placed drawing context. Other fields retain function selection, including the selected part article. Read-only page.local_name returns the page number without its section prefix; page.section_pages counts pages in the same section (top-level pages form section zero). Both update after edits.

The page_template_values feature retains a page template's values map when saving, exchanging and inserting it. Empty legacy maps remain compatible. The shared list_page_templates command returns these defaults, and every frontend applies them through the same insertion operation. Importers should check both features before supplying reusable source frames with editable context fields.

The page_frame_fields feature adds computed page.section_last_number, page.previous_local_name and page.next_local_name properties. The last number uses natural ordering; adjacent pages follow the editable order of their section, with empty values at either end. For sheets 11 through 23, the page count is 13 while the last number is 23. Insertions, deletions and renumbering update these fields. page.function_designation and page.location_designation include the = and + aspect signs, including bare signs for an unconfigured aspect. These read-only properties are available through the shared property registry, symbol attribute blocks, free-text placeholders and title-block forms.

The function_cable_references host feature provides the editable Function property function.cable, containing the full cable tag for a placed marker. Renaming the cable through the cable table or editor updates these references, matching marker tags, wire assignments, connection points and definition lines, including inactive model options. Ordinary device symbols sharing a tag remain separate. Deleting the inventory entry clears its explicit marker association and core assignments, removes its owned route and accessory definitions, and retains ordinary device endpoint places. Portable macro/clipboard content carries the referenced cable and maps the association to the fresh pasted cable tag. Use set_properties on function:<symbol id> to edit the association; existing registry operations apply equally to desktop, CLI and MCP.

Cable tag cells (table_set, table cables, column Cable) and the cable manager use the same atomic ops::rename_project_cable operation. It trims the entered tag, validates its designation, refuses duplicates and released drawing changes, and updates references only after validation. The cable manager keeps draft text outside the project until Enter or focus loss; Escape cancels the draft.

A function with an explicit function.cable reference resolves its selected and assigned primary article through that cable inventory entry. A changed, cleared or missing cable article is reflected immediately, including direct cable property and table edits. Cached function part selections do not shadow this association. Ordinary function article selection keeps its existing explicit-reference rules.

The cable_property_blocks feature resolves Cable-class rows in symbol attribute blocks against the symbol's explicit function.cable reference. A missing explicit target stays unresolved; symbols without that reference retain the legacy same-tag cable context. This context also applies to placed cable properties and is shared by the canvas and exports. The symbol editor offers Cable properties. Placed Part-class properties resolve the function's selected catalog article, including the current linked cable article and non-primary device assignments.

Hosts advertising placed_wire_labels retain Wire.labels even when hide_labels suppresses automatic labels. Each layout contains kind (Core, Cable, Number or Color), attachment fraction along (0..1 from a to b), offset in drawing mm, size, anchor, angle and optional RGB color. Text comes from the current owning wire. update_wire accepts labels: {"items": [...]} to replace the layouts, or an empty items array to remove them. Invalid layouts reject the entire command. Labels follow their wire during editing and are redistributed once when routing creates new legs.

Unattached core markers can retain independent editable text in the indexed function.cable_core[1] through [64] properties. Importers should use placed wire labels for markers that reference an actual physical wire, so wire core edits change the displayed text automatically.

rename_symbol_device accepts a placed symbol id and new_tag. An explicit function.cable reference matching its displayed tag selects the cable inventory; ordinary shared-tag devices remain independent. Missing cable targets, duplicate cable tags and released drawing references reject the operation. The editor's selected-function rename uses the same operation. rename_device follows the cable inventory when no ordinary device identity shares that tag. Material owner references follow cable edits only while the old tag has no ordinary device identity. Renaming a device or cable can retain an unchanged imported prefix containing spaces; the new final device name still follows the normal tag validation rules.

Explicit cabinet orientation

Hosts advertising explicit_panel_rotations preserve optional numeric PanelItem.rotation values 0, 90, 180 and 270 (clockwise in the face plane). Negative multiples of 90 are accepted and normalized. Missing values preserve legacy dimension inference; explicit zero suppresses that inference. The saved x, y, w, h remain the already oriented footprint. Importers must not rotate those dimensions a second time. Graphics, meshes, connection point positions and exit directions, assembly accessories and exact drilling patterns follow the angle.

set_panel_item(rotation: ...) changes orientation without moving or resizing the footprint. infer_rotation: true clears the explicit angle; supplying both is an error. Item queries return rotation and effective_rotation. arrange_panel_items(action: "rotate") turns selected items 90 degrees around their centres and swaps width and height, matching the editor Rotate action.

Optional boolean parameters in the editor offer Use plugin default, Enabled and Disabled. The first omits the argument so external plugins retain their documented defaults; explicit false remains distinct from omission in every frontend.

Symbol definition revisions

merge_symbol_definitions accepts definitions: {"items": [<UserSymbol>, ...]}. The complete batch is deserialized and validated before any change. It returns keys, one resolved key per input in source order, and added, the number of new definitions. Identical typed definitions reuse their existing key. Conflicts try <original>_import_1, _import_2, and so on, reusing an equal existing revision. Existing definitions and page instances remain unchanged. Two inputs sharing an original key can return different revision keys, so importers should map references within each incoming clip rather than build one global map of original keys.

The editor, CLI, MCP and external plugins all use the same registered command. Native typing normalizes default fields and numeric precision before comparison; importers should use this operation instead of comparing raw saved JSON objects. This is the same core operation used when pasting portable macro definitions.

Authored plot frames

Hosts advertising plot_frame_artwork accept forms.frames[].artwork, an array of symbol drawing primitives in paper millimetres. Nonempty artwork replaces the generated border and title block; visible controls the complete frame drawing. Property blocks resolve live project and page properties for each page using it. Artwork belongs to the reusable frame and is not selectable circuit content. The shared set_frame command accepts optional JSON artwork: {"items": [...]}; an empty items array restores the generated frame. list_frames includes the artwork. Canvas, frame preview and exports use the same renderer. Older project files keep generated frames.

Title block images and text styles

Hosts advertising title_block_images accept Image elements in title blocks (forms.title_blocks[].items) and in drawn report forms (layout.header, layout.row): {"type": "Image", "a": {…}, "b": {…}, "picture": {"file": {"name", "data"}, "px": [w, h]}} with a base64 PNG or JPEG fitted into the rectangle a..b keeping its aspect ratio. Without picture the element shows info.logo (same shape as picture), the project logo that the cover page also shows: above the project name, or fitted into info.cover_logo (x, y, width, height in mm from the top left corner of the drawing area; command set_cover_logo). Text elements take optional bold, italic and angle (degrees, counter-clockwise). Placeholders {page.previous}, {page.next} and {rev.N.name|date|author|description} (N-th last released revision) are filled like the others. The shared commands list_title_blocks, set_title_block (elements as items: {"items": [...]}), delete_title_block, set_default_title_block and set_page (title_block) edit them; the command line adds add_title_block_image and set_project_info (logo) for image files.

Form conditions, styles, QR codes and stamps

Hosts advertising form_customization accept these further fields of forms (all optional, older files and plugins leave them out):

  • Every element of a title block or drawn form takes show: {"filled": "…", "page_types": [...]}: it is drawn only when filled (with placeholders) is not empty and only on pages of the given types (schematic, cover, report, mounting, overview, graphic, document). Line, Rect and Text take color: [r, g, b], Line and Rect dashed. {"type": "Qr", "a": {…}, "size": mm, "text": "…"} draws a QR code (byte mode, level M) of the filled text.
  • forms.page_type_title_blocks maps page types to title block names and forms.frames[].title_block names the title block of a plot frame. A page uses its own title block, else the one of its type, of its frame, the project default, Standard.
  • forms.stamp (draft, review, approved, released, size, angle, color) is a text drawn across every page by the state of the revision workflow; placeholders {rev.status}, {rev.approved_by}, {rev.approved_date} and {rev.N.approved_by|approved_date} give the state and who approved a revision.
  • Report forms take totals (columns summed below the last row), shade_rows and align ({column: "Left" | "Center" | "Right"}); frozen report pages keep them in totals, shade_rows and align of their table.

Commands: set_stamp, set_default_title_block (page_type), set_frame (title_block); set_title_block takes the new element fields. The form library (file and the parts server library forms, GET / PUT /api/v1/libraries/forms) also carries frames; the command line loads and publishes it with parts_company_forms (with publish).

Live function reference fields

Hosts advertising function_cross_references resolve the read-only function.cross_references property from the current native device/interruption index and reference settings. Property-block rows retain authored placement and flow while their text follows renamed pages, sections and changed device targets. Their per-line target-page links survive PDF export; canvas and SVG text use the same resolver. An explicit field replaces the automatic reference text; ordinary symbols retain automatic annotations. Library/ghost previews without project context leave the reference row empty.

The shared list_cross_references command returns each function's id, page, tag, multiline text and references (text and target page, null for missing targets). Optional id and page filters use native symbol IDs and page names. The property is also available through get_properties and property pickers; set_properties rejects attempts to freeze its computed value.