Skip to content

Machine becomes stuck when the bootspec lookup fails #49

Description

@l0wl3vel

Description

Problem

When the gRPC call to metal-api's BootService fails, pixie logs the error and serves nothing. iPXE has no boot URLs, gives up, and never retries — the machine sits idle indefinitely and never registers. Only an out-of-band power reset recovers it.

Observed in mini-lab (pixie v0.4.1), where two machines PXE-booted simultaneously and one lost:

18:26:19  boot resp {"kernel":"…/metal-kernel","init_ram_disks":["…/metal-hammer-initrd.img.lz4"]}   ← machine02, ok
18:26:34  ERROR boot  error="rpc error: code = Unavailable desc = error reading from server: EOF"    ← machine01
18:26:34  Couldn't get a bootspec for  mac=aa:c1:ab:22:0d:8e

metal-api was healthy. The RPC failure was a one-off on the path through the envoy Gateway LB. make power-reset-machine01 booted the machine cleanly on the next attempt and it registered normally.

Impact

A single transient RPC failure permanently strands a machine. Automated recovery using metal-stack tools is not possible, as metal-api never learns the machine exists. In CI this is a hard integration-test failure; in production it is a machine that silently never comes up.

Suggested fix

When the bootspec lookup fails, return an iPXE script that retries instead of returning nothing — e.g. sleep, then chain the bootspec URL again, with a bounded retry count falling back to reboot.