From 6714e5e2c9188b589b023b4a1f1827ea8e391139 Mon Sep 17 00:00:00 2001 From: hansen1506 <140017796+hansen1506@users.noreply.github.com> Date: Fri, 23 Oct 2026 01:49:39 +0200 Subject: [PATCH 1/2] Update HeatPumpType.md - WH-ADC0309K3E5AN + WH-UDZ09KE5 TOP92 | Heat_Pump_Model | E2 D5 0F 36 99 02 D6 10 68 95 IDU: WH-ADC0309K3E5AN ODU: WH-UDZ09KE5 KIT: KIT-ADC09K3E5AN Power [kW]: 9 1ph/3ph: 1ph T-CAP/HP: HP (All-In-One K-series) Best regards hansen --- HeatPumpType.md | 1 + 1 file changed, 1 insertion(+) diff --git a/HeatPumpType.md b/HeatPumpType.md index afe95c05..9dbc6daa 100644 --- a/HeatPumpType.md +++ b/HeatPumpType.md @@ -85,6 +85,7 @@ Assuming that bytes from #129 to #138 are unique for each model of Aquarea heat |78 | E2 D5 0B 34 99 83 92 0D 29 98 | WH-SDC0509L3E5 | WH-WDG09LE5 | KIT-WC09L3E5 | 9 | 1 ph | HP - split L-series 3kW elec heating - revised model | |79 | E2 D5 0B 12 95 02 D6 0F 70 95 | WH-SXC12K6E5 | WH-UXZ12KE5 | KIT-WXC12K6E5 | 12 | 1 ph | T-CAP Bi-bloc K-series | |80 | 12 D7 0C 98 14 33 94 0C 83 10 | WH-SDC0316M9E8 | WH-WXG09ME8 | Monoblock | 9 | 3ph | T-CAP - M-series | +|81 | E2 D5 0F 36 99 02 D6 10 68 95 | WH-ADC0309K3E5AN | WH-UDZ09KE5 | KIT-ADC09K3E5AN | 9 | 1ph | HP - All-In-One K-series - DHW 185l - AN | All bytes are used for Heat Pump model identification in the code. Note: These are the heat pump types that users have verified and reported back the model. HeishaMon should work with all H,J and M generation Aquarea heat pumps. From 65cf0f613c4b79f049c71c56965d10f6a7089c6f Mon Sep 17 00:00:00 2001 From: hansen1506 <140017796+hansen1506@users.noreply.github.com> Date: Fri, 23 Oct 2026 02:07:44 +0200 Subject: [PATCH 2/2] Update HeatPumpType.md Another PR also used ID 81, so I renumbered mine to 82. --- HeatPumpType.md | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/HeatPumpType.md b/HeatPumpType.md index 9dbc6daa..b2126979 100644 --- a/HeatPumpType.md +++ b/HeatPumpType.md @@ -85,7 +85,7 @@ Assuming that bytes from #129 to #138 are unique for each model of Aquarea heat |78 | E2 D5 0B 34 99 83 92 0D 29 98 | WH-SDC0509L3E5 | WH-WDG09LE5 | KIT-WC09L3E5 | 9 | 1 ph | HP - split L-series 3kW elec heating - revised model | |79 | E2 D5 0B 12 95 02 D6 0F 70 95 | WH-SXC12K6E5 | WH-UXZ12KE5 | KIT-WXC12K6E5 | 12 | 1 ph | T-CAP Bi-bloc K-series | |80 | 12 D7 0C 98 14 33 94 0C 83 10 | WH-SDC0316M9E8 | WH-WXG09ME8 | Monoblock | 9 | 3ph | T-CAP - M-series | -|81 | E2 D5 0F 36 99 02 D6 10 68 95 | WH-ADC0309K3E5AN | WH-UDZ09KE5 | KIT-ADC09K3E5AN | 9 | 1ph | HP - All-In-One K-series - DHW 185l - AN | +|82 | E2 D5 0F 36 99 02 D6 10 68 95 | WH-ADC0309K3E5AN | WH-UDZ09KE5 | KIT-ADC09K3E5AN | 9 | 1ph | HP - All-In-One K-series - DHW 185l - AN | All bytes are used for Heat Pump model identification in the code. Note: These are the heat pump types that users have verified and reported back the model. HeishaMon should work with all H,J and M generation Aquarea heat pumps.