docs(s001): PROOF corrections — the heartbeat fires, and Windows was serving
AC8 gains an appended correction rather than a rewrite. The verdict said the heartbeat 'has
never once been the mechanism that worked'; run 34080826739 shows it firing at 1824 ms, inside
its documented timeout and well inside AC8's 5 s bound.
AC3 gains the reason Windows never appeared to serve: it was serving on 58912 and my step
curled 58911, the ShutdownManager's TCP heartbeat socket on the one OS that uses TCP. The
connection armed the heartbeat and the app shut itself down. Both readings were wrong and the
same defect caused both.
What still stands: the production sidecar orphans with no frontend attached, three runs, past
7.6 s, still serving. F1 is not closed — but what slice 100 must guarantee is better specified
now, and F2 is filed: on Windows the shutdown channel is an unauthenticated loopback TCP port
whose number is written to a file, so any local process that connects and disconnects shuts
Trinity down.
mix gate exit=0.